omp
no shutdown
graceful-restart
advertise connected
advertise static
!
security
ipsec
authentication-type ah-sha1-hmac sha1-hmac
!
!
vpn 0
interface ge0/0
ip dhcp-client
tunnel-interface
encapsulation ipsec
no allow-service bgp
allow-service dhcp
allow-service dns
allow-service icmp
no allow-service sshd
no allow-service netconf
no allow-service ntp
no allow-service ospf
no allow-service stun
!
no shutdown
!
!
vpn 512
interface mgmt0
ip address 192.168.1.1/24
no shutdown
!
Maintenance and Troubleshooting
Now that you have installed and connected the vEdge 1000 router, you can monitor and troubleshoot the
various LEDs and system alarms on the router.
Alarm Severity Levels
The system alarms on the vEdge 1000 router have two types of severity levels:
• Major (red)—Indicates a critical situation on the router resulting from one of two conditions:
• One or more hardware components on the router has failed.
• One or more hardware components on the router has exceeded the temperature threshold.
A major alarm condition requires immediate attention. If a temperature related major alarm persists for more
than five minutes, the router will shut down.
• Minor (yellow)—Indicates a warning on the router that, if left unattended, might result in an interruption
in router operation or degradation in router performance. A yellow alarm condition requires further
monitoring and/or maintenance.
Hardware Installation Guide for vEdge Routers
150
vEdge 1000 Router
Maintenance and Troubleshooting
Содержание vEdge 100
Страница 2: ... Cisco Systems Inc All rights reserved ...
Страница 32: ...Hardware Installation Guide for vEdge Routers 26 vEdge 100 Router Return Hardware ...
Страница 88: ...Hardware Installation Guide for vEdge Routers 82 vEdge 100m Router Return Hardware ...
Страница 164: ...Hardware Installation Guide for vEdge Routers 158 vEdge 1000 Router Return Hardware ...
Страница 258: ...Hardware Installation Guide for vEdge Routers 252 vEdge 5000 Router Return Hardware ...