Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
78
TECHNICAL SPECIFICATIONS
The general power specifications for the C220 M3 LFF server 650 W (AC) power supply are listed in
Table 41
.
Power supply output voltage
Main power: 12 VDC
Standby power: 12 VDC
Power supply efficiency
CSCI Platinum
NOTE:
AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Table 42 UCS C220 M3 LFF 650 W AC Power Supply Specifications
Description
Specification
AC input voltage
90 to 264 VAC self-ranging,
100 to 120 VAC nominal
200 to 240 VAC nominal
AC input frequency
Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)
Maximum AC input current
7.6 A maximum @ 100 VAC
3.65 A maximum @ 208 VAC
Maximum AC inrush current
11 A peak @ 35° C, 208 VAC
Maximum output power for the
power supply
650 W
Power supply output voltage
Main power: 12 VDC
Standby power: 12 VDC
Power supply efficiency
CSCI Platinum
NOTE:
AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Table 41 UCS C220 M3 LFF 450 W AC Power Supply Specifications
(continued)
Description
Specification