background image

C

ISCO

 S

YSTEMS

P

UBLICATION

 H

ISTORY

 

170 W

EST

 T

ASMAN

 D

R

 

S

AN

 J

OSE

, CA, 95134

R

EV

 B.2

M

AY

 27, 2014

 

WWW

.

CISCO

.

COM

Spec Sheet

Cisco UCS C220 M3

High-Density Rack Server 

 

(Large Form Factor Hard 

Disk Drive Model)

Содержание UCS C220 M3

Страница 1: ...CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV B 2 MAY 27 2014 WWW CISCO COM Spec Sheet Cisco UCS C220 M3 High Density Rack Server Large Form Factor Hard Disk Drive Model ...

Страница 2: ...M MEDIA KIT 48 STEP 16 SELECT SERVICE and SUPPORT LEVEL 49 OPTIONAL STEP ORDER RACK s 54 OPTIONAL STEP ORDER PDU 55 SUPPLEMENTAL MATERIAL 56 CHASSIS 56 CPUs and DIMMs 57 Physical Layout 57 Memory Population Rules 59 DIMM Population Order 60 Recommended Memory Configuration 61 Supported DIMM Populations 64 Low Voltage DIMM Considerations 65 RAID Details 66 RAID Option ROM OPROM Settings 67 Serial P...

Страница 3: ...Cisco UCS C220 M3 High Density Rack Server Large Form Factor Hard Disk Drive Model 3 CONTENTS Power Specifications 77 Environmental Specifications 80 Compliance Requirements 81 ...

Страница 4: ...Cisco UCS C220 M3 High Density Rack Server Large Form Factor Hard Disk Drive Model 4 ...

Страница 5: ...erver extends the capabilities of Cisco s Unified Computing System portfolio in a 1U form factor with the addition of the Intel Xeon E5 2600 v2 and E5 2600 series processor family CPUs that deliver significant performance and efficiency gains In addition the UCS C220 M3 server provides 16 DIMM slots four 3 5 inch drives and 2 x 1 GbE LOM ports delivering outstanding levels of density and performan...

Страница 6: ...rmation about the KVM cable connection see KVM CABLE page 75 1 Power button power status LED 6 Power supply status LED 2 Identification button LED 7 Network link activity LED 3 System status LED 8 Asset tag serial number 4 Fan status LED 9 KVM connector used with KVM cable that provides two USB one VGA and one serial connector 5 Temperature status LED 10 Drives up to four hot swappable 3 5 inch dr...

Страница 7: ...2 Low profile PCIe slot on riser half height half length x16 connector x8 lane width 7 Dual 1 GbE ports LAN1 and LAN2 3 Slot 1 Standard profile PCIe slot on riser full height half length x24 connector x16 lane width supports Cisco Virtual Interface Card VIC 8 USB ports 4 VGA video connector 9 Rear Identification button LED 5 Serial port RJ 45 connector 1 Notes 1 Serial port pinout details are give...

Страница 8: ... teaming Expansion slots Two PCIe slots on a riser card One full height profile half length slot with x24 connector and x16 lane One half height profile half length slot with x16 connector and x8 lane Internal storage devices Drives are installed into front panel drive bays that provide hot pluggable access Large Form Factor LFF drives Up to four 3 5 inch SAS or SATA hot swappable hard disk drives...

Страница 9: ...ne Card supports up to eight SAS SATA drives limited to four drives for the C220 M3 LFF chassis supporting RAID 0 1 5 10 and 50 This card has a product ID PID of UCSC RAID 11 C220 Cisco UCSC RAID SAS 2008M 8i Mezzanine Card supports up to eight SAS SATA drives limited to four drives for the C220 M3 LFF chassis supporting RAID 0 1 and 10 This card has a product ID PID of UCSC RAID MZ 220 PCIe RAID ...

Страница 10: ...e 1 Gb Base T Ethernet LAN ports support the wake on LAN WoL standard InfiniBand The bus slots in this server support the InfiniBand architecture Front Panel A front panel controller provides status indications and control buttons Power subsystem Up to two 450 W AC 650 W AC or 930 W DC power supplies One is mandatory one more can be added for 1 1 redundancy ACPI This server supports the advanced c...

Страница 11: ...PCIe OPTION CARD s page 31 STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES page 33 STEP 8 ORDER POWER SUPPLY page 37 STEP 9 SELECT AC POWER CORD s page 38 STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM page 41 STEP 11 ORDER A TRUSTED PLATFORM MODULE OPTIONAL page 42 STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE OPTIONAL page 43 STEP 13 ORDER USB 2 0 DRIVE OPTIONAL page 44 STEP 14 SELECT...

Страница 12: ...ncludes one tool less rail kit UCSC RAIL1 Does not include power supply CPU memory hard disk drives HDDs SD cards or plug in PCIe cards Table 2 PID of the C220 M3 High Density LFF Rack Base Server Product ID PID Description UCSC C220 M3L UCS C220 M3 LFF no CPU memory HDD power supply SD card or PCIe cards with rail kit NOTE Use the steps on the following pages to configure the server with the comp...

Страница 13: ...M Clock Support MHz 1 Intel Xeon E5 2600 v2 UCS CPU E52697B E5 2697B v2 2 70 130 30 12 8 GT s 1866 UCS CPU E52695B E5 2695B v2 2 40 115 30 12 8 GT s 1866 UCS CPU E52690B E5 2690B v2 3 00 130 25 10 8 GT s 1866 UCS CPU E52680B E5 2680B v2 2 80 115 25 10 8 GT s 1866 UCS CPU E52670B E5 2670B v2 2 50 115 25 10 8 GT s 1866 UCS CPU E52667B E5 2667B v2 3 30 130 25 8 8 GT s 1866 UCS CPU E52660B E5 2660B v2...

Страница 14: ...U E5 2643 E5 2643 3 30 130 10 4 8 GT s 1600 UCS CPU E5 2640 E5 2640 2 50 95 15 6 7 2 GT s 1333 UCS CPU E5 2630 E5 2630 2 30 95 15 6 7 2 GT s 1333 UCS CPU E5 2630L E5 2630L 2 00 60 15 6 7 2 GT s 1333 UCS CPU E5 2620 E5 2620 2 00 95 15 6 7 2 GT s 1333 UCS CPU E5 2609 E5 2609 2 40 80 10 4 6 4 GT s 1066 Notes 1 If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU...

Страница 15: ...e rows of Table 3 on page 13 Caveats You can select either one processor or two identical processors For optimal performance select DIMMs with the highest clock speed for a given processor see Table 3 on page 13 If you select DIMMs whose speeds are lower or higher than that shown in the tables suboptimal performance will result For configurations that use 130 W or 135 W CPUs the minimum power supp...

Страница 16: ...memory features are DIMMs Clock speed 1866 1600 or 1333 MHz Ranks per DIMM 1 2 or 4 Operational voltage 1 5 V or 1 35 V Registered or unbuffered ECC DDR3 DIMMs RDIMMs or UDIMMs or load reduced DIMMs LRDIMMs Memory is organized with four memory channels per CPU with up to two DIMMs per channel as shown in Figure 4 Figure 4 C220 M3 LFF Memory Organization ...

Страница 17: ...vailable DDR3 DIMMs Product ID PID PID Description Voltage Ranks DIMM DIMM Options1 Notes 1 1866 MHz DIMMs cannot be used with Intel Xeon E5 2600 CPUs UCS ML 1X324RY A 32 GB DDR3 1600 MHz LR DIMM PC3 12800 4R x4 1 35v 1 5 1 35 V2 2 Dual voltage DIMM operates at 1 5 V with BIOS is set for memory performance mode default or 1 35 V when BIOS is set for power savings mode 4 UCS ML 1X324RZ A 32 GB DDR3...

Страница 18: ...4 6 or 8 identical DIMMs The DIMMs will be placed by the factory as shown in the following table Select the memory mirroring option N01 MMIRROR as shown in Table 4 on page 17 3 2 CPU configuration without memory mirroring Select from 1 to 8 DIMMs per CPU Refer to Memory Population Rules page 59 for more detailed information Total Number of DIMMs CPU 1 DIMM Placement in Channels for identical DIMMs...

Страница 19: ...tion N01 MMIRROR as shown in Table 4 on page 17 Number of DIMMs per CPU CPU 1 DIMM Placement in Channels for identical dual rank DIMMs CPU 2 DIMM Placement in Channels for identical dual rank DIMMs Blue Slots Black Slots Blue Slots Black Slots 2 A1 B1 E1 F1 4 A1 B1 C1 D1 E1 F1 G1 H1 61 Notes 1 Not recommended for performance reasons A1 B1 C1 A2 B2 C2 E1 F1 G1 E2 F2 G2 8 A1 B1 C1 D1 A2 B2 C2 D2 E1 ...

Страница 20: ... be even for mirroring When single and dual rank DIMMs are populated for 2DPC always populate the dual rank DIMM in the blue DIMM slot and the single rank DIMM in the black DIMM slot only the 4GB DIMMs are single rank Table 5 DIMM Memory Speeds DIMM Speed DPC 1333 MHz Capable CPU 1600 MHz Capable CPU 1866 MHz Capable CPU LRDIMM RDIMM DR SR LRDIMM RDIMM DR SR LRDIMM RDIMM DR SR Voltage Voltage Volt...

Страница 21: ...ields faster memory speeds than when the BIOS is set for the memory to run in power savings mode Memory speed is dependent on factors such as CPU choice DIMM choice DIMM population how many DIMMs per channel are populated BIOS setting For the DIMMs to run in power savings mode 1 35 V if the DIMM supports this change the BIOS setting to power savings mode For more information regarding memory see C...

Страница 22: ... of the embedded RAID upgrade options you will have an embedded SATA only RAID controller that supports up to four SATA only drives RAID 0 1 10 NOTE When creating a RAID volume follow these guidelines Use the same capacity for each drive in the volume Use either all SAS drives or all SATA drives Use either all HDDs or all SSDs NOTE The number of RAID groups virtual drives supported per controller ...

Страница 23: ... Onboard RAID consisting of a plug in storage controller unit SCU supporting up to 8 internal SAS SATA drives SAS and SATA drives can be mixed This option supports RAID 0 1 and 10 and operates at 3 Gb s Operating systems supported are Windows and Linux only no VMware support UCSC RAID ROM15 Onboard RAID consisting of two plug in modules an SCU plus a software key module supporting up to 8 internal...

Страница 24: ...ions available RAID 0 1 and 10 see the RAID PIDs section in this table No data cache backup Table 8 Available PCIe RAID Controller Options Product ID PID PID Description RAID Controllers1 Note that PCIe RAID controllers are installed by default in slot 1 for 1 CPU systems and slot 2 for 2 CPU systems UCS RAID9271 8I or UCS RAID9271CV 8I LSI MegaRAID SAS 9271 8i or 9271CV 8i RAID controller card wi...

Страница 25: ...AID Configuration section in this table Note that factory RAID configuration is not available for these controllers because the factory does not control the storage array attached to them Table 8 Available PCIe RAID Controller Options continued Product ID PID PID Description NOTE For SAS 9285CV 8e or 9286CV 8e external drive enclosure support see the compatibility list enclosure section at the fol...

Страница 26: ...equires exactly two drives with the same size speed capacity R2XX RAID5 Factory preconfigured RAID option Enable RAID 5 Setting Requires a minimum of three drives of the same size speed capacity R2XX RAID6 Factory preconfigured RAID option Enable RAID 6 Setting Requires a minimum of four drives of the same size speed capacity R2XX RAID10 Factory preconfigured RAID option Enable RAID 10 Setting Req...

Страница 27: ...s up to four SATA only drives RAID 0 1 10 Table 9 Supported RAID Configurations Server CPUs Embedded RAID Mezz RAID1 Internal PCIe RAID 12 Internal PCIe RAID 23 External PCIe RAID4 Drives Supported PCIe Slots5 1 2 C220 M3 LFF 1 Enabled Not allowed6 Not allowed Not allowed Not allowed 4 internal A U C220 M3 LFF 1 Not allowed Not allowed Installed slot 1 default Not allowed Not allowed 4 internal O ...

Страница 28: ...rom a device make sure its OPROM is enabled it is in the proper boot sequence and its BIOS is configured for a bootable device 2 If you want to boot from a device other than the 9271 8i or 9271CV 8i MegaRAID PCIe card you can leave the card installed Just disable the OPROM for its slot and the system will boot even with the card installed 3 Dual RAID controllers are not supported in this server 4 ...

Страница 29: ...e 10 Available Hot Pluggable Sled Mounted HDDs Product ID PID PID Description Drive Type Capacity HDDs UCS HD4T7KS3 E 4 TB SAS 7 2K RPM 3 5 inch HDD SAS 4 TB UCS HDD3TI2F214 3 TB SAS 7 2K RPM 3 5 inch HDD SAS 3 TB UCS HDD2TI2F213 2 TB SAS 7 2K RPM 3 5 inch HDD SAS 2 TB UCS HDD1TI2F212 1 TB SAS 7 2K RPM 3 5 inch HDD SAS 1 TB NOTE When creating a RAID volume follow these guidelines Use the same capa...

Страница 30: ...you have not selected an onboard RAID upgrade option LSI ROM1 or LSI ROM15 a mezzanine card or a PCIe RAID controller for internal drives LSI MegaRAID SAS 9271 8i or 9271CV 8i you may select up to 4 SATA only drives which will be controlled with the embedded SATA only RAID controller Otherwise select up to four SAS SATA drives listed in Table 10 You can mix SAS and SATA drives Caveats You can mix ...

Страница 31: ...l Port 40 Gb QSFP CNA Half UCSC PCIE ESFP Emulex OCe11102 FX dual port 10 GbE FCoE CNA Gen 3 CNA Half UCSC PCIE QSFP Qlogic QLE8242 CU dual port 10 GbE FCoE CNA Half UCSC PCIE B3SFP Broadcom 57810 10Gb A FEX SFP Half UCSC PCIE Q8362 Qlogic QLE8362 dual port 10 GbE FCoE CNA Half Network Interface Cards NICs N2XX ABPCI01 M3 Broadcom 5709 Dual Port 1Gb w TOE iSCSI for M3 Servers Half N2XX ABPCI03 M3 ...

Страница 32: ...ive2 cards are installed they must be plugged into slot 1 Note that the only the Cisco UCS 3 0 TB MLC Fusion ioDrive2 card is full height all other Fusion ioDrive2 cards are half height and therefore may need an adapter to hold them securely in the full height slot For 2 CPU systems N2XX AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half UCSC PCIE Q2672 Qlogic QLE2672 CSC 16Gb Fibre Chann...

Страница 33: ...artbeat LED on the top of the card that indicates when firmware is active To use this card for UCS integration Cisco UCS Manager mode with Cisco UCS Manager 2 1 0 or later the minimum card firmware and uboot image level is 2 1 0 306 To help ensure that your operating system is compatible with the card you have selected check the Hardware Compatibility List at this URL http www cisco com en US prod...

Страница 34: ...r Each Network Card Ordered You may choose one or two SFP optical modules cables for each compatible PCIe network card ordered You would normally order two modules for connecting to the primary and redundant network switching equipment With the SFP optical modules you can use common fiber optic cables widely available See Figure 5 on page 36 for typical SFP and twinax connections to the network ca...

Страница 35: ...7810 10Gb A FEX SFP Yes Yes No UCSC PCIE Q8362 Qlogic QLE8362 dual port 10 GbE FCoE CNA Yes Use Qlogic SFP UCSC PCIE E14102 Emulex OCe14102 UX dual port 10 GbE FCoE CNA Yes Yes No Network Interface Cards NICs N2XX ABPCI01 M3 Broadcom 5709 Dual Port Ethernet PCIe Adapter for M3 Servers Yes No No N2XX ABPCI03 M3 Broadcom 5709 Quad Port 10 100 1Gb NIC w TOE iSCSI for M3 Servers Use RJ45 Ethernet cabl...

Страница 36: ...talled do not change SFP UCSC PCIE Q2672 Qlogic QLE2672 CSC 16Gb Fibre Channel HBA with SR Optics No Preinstalled do not change SFP UCSC PCIE E16002 Emulex LPe16002 M6 16Gb Fibre Channel HBA with SR Optics No Preinstalled do not change SFP Notes 1 This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable Table 14 PCIe Card Compatibility continued PCIe Cards Twinax Cables Cisco SFP Modules SF...

Страница 37: ...he power calculator at the following link to determine the needed power based on the options chosen CPUs drives memory and so on https express salire com Go Cisco Cisco UCS Power Calculator aspx NOTE For configurations that use 130 W or 135 W CPUs the minimum power supply required is 650 W UCSC PSU 650W See STEP 2 SELECT CPU s page 13 Table 15 Power Supply PIDs Product ID PID PID Description UCSC ...

Страница 38: ...server Table 16 Available Power Cords Product ID PID PID Description Images R2XX DMYMPWRCORD No power cord dummy PID to allow for a no power cord option Not applicable CAB N5K6A NA Power Cord 200 240V 6A North America CAB AC L620 C13 AC Power Cord NEMA L6 20 C13 2M 6 5ft CAB C13 CBN CABASY WIRE JUMPER CORD 27 L C13 C14 10A 250V CAB C13 C14 2M CABASY WIRE JUMPER CORD PWR 2 Meter C13 C14 10A 250V CA...

Страница 39: ... 16 Available Power Cords Product ID PID PID Description Images 186571 2500 mm Cordset rating 10 A 250 500 V MAX Length 8 2 ft Plug EL 219 IRAM 2073 Connector EL 701 IEC60320 C13 Plug Cordset rating 10 A 250 V 500 V MAX Length 2500mm 186580 Connector EL 701C EN 60320 C15 EL 210 BS 1363A 13 AMP fuse Cordset rating 10A 250V 2500 mm Plug EL 218 CCEE GB2009 186573 Connector EL 701 IEC60320 C13 Connect...

Страница 40: ...5 15 Plug North America CAB 250V 10A BR Power Cord 250V 10A Brazil CAB JPN 3PIN Power Cord 3PIN Japan Image not available Table 16 Available Power Cords Product ID PID PID Description Images Plug I 3G CEI 23 16 Connector C15M EN60320 C15 Cordset rating 10 A 250 V Length 8 ft 2 in 2 5 m 186575 Plug MP232 R Cordset rating 10 A 250 V Length 8 ft 2 in 2 5 m 186578 Connector IEC 60320 C15 Plug Cordset ...

Страница 41: ...ar of the server and is used for cable management Use Table 17 to order a cable management arm For more information about the cable management arm see the Cisco UCS C220 M3 Installation and Service Guide at this URL http www cisco com en US docs unified_computing ucs c hw C220 install C220 pdf Table 17 Cable Management Arm Product ID PID PID Description UCSC CMA1 Cable Management Arm for C220 rack...

Страница 42: ...used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is listed in Table 18 Table 18...

Страница 43: ...ds or one 32 GB SD card See Figure 6 on page 56 for the location of the SD cards There are two locations SD1 and SD2 Caveats If you install a 32 GB SD card you cannot install a 16 GB SD card Table 19 16 GB Secure Digital SD Card blank Product ID PID PID Description UCS SD 16G 16GB SD Card optional Table 20 32 GB Secure Digital SD Card Product ID PID PID Description UCS SD 32G S 32GB SD Card for UC...

Страница 44: ...13 ORDER USB 2 0 DRIVE OPTIONAL You can order one optional USB 2 0 drive The USB drive ordering information is listed in Table 21 See Figure 6 on page 56 for the location of the USB connector Table 21 USB 2 0 Drive Product ID PID PID Description UCS USBFLSH S 4GB 4GB Flash USB Drive shorter length for all servers except C260 ...

Страница 45: ...VR 2S 1G 5A SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys 5yr Support Reqd SLES SVR 2S UG 1A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 1yr Support Reqd SLES SVR 2S UG 3A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 3yr Support Reqd SLES SVR 2S UG 5A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 5yr Support Reqd SLES SHA 2S 1A SUSE Linux High Availability Ext 1 2 CPU 1yr Support Reqd SLES SHA 2S 3A SUSE Linux...

Страница 46: ...BMC 012 BMC BPPM Per Server BMC SE 4C BMC BladeLogic Standard Edition 4 Cores Support Required BMC SE 6C BMC BladeLogic Standard Edition 6 Cores Support Required BMC SE 8C BMC BladeLogic Standard Edition 8 Cores Support Required BMC SE 10C BMC BladeLogic Standard Edition 10 Cores Support Required BMC AE 4C BMC BladeLogic Advanced Edition 4 Cores Support Required BMC AE 6C BMC BladeLogic Advanced E...

Страница 47: ...d VMW VS5 ENT 5A VMware vSphere 5 Enterprise for 1 CPU 5 Yr Support Rqd VMW VS5 ENTP 1A VMware vSphere 5 Enterprise Plus for 1 Processor 1 Year Support Rqd VMW VS5 ENTP 2A VMware vSphere 5 Enterprise Plus for 1 CPU 2 Yr Support Rqd VMW VS5 ENTP 3A VMware vSphere 5 Enterprise Plus for 1 Processor 3 Year Support Rqd VMW VS5 ENTP 4A VMware vSphere 5 Enterprise Plus for 1 Processor 4 Year Support Rqd ...

Страница 48: ...roduct ID PID PID Description RHEL 6 RHEL 6 Recovery Media Only Multilingual SLES 11 SLES 11 media only multilingual MSWS 08R2 STHV RM Windows Svr 2008 R2 ST 1 4CPU 5CAL Media MSWS 08R2 ENHV RM Windows Svr 2008 R2 EN 1 8CPU 25CAL Media MSWS 08R2 DCHV RM Windows Svr 2008 R2 DC 1 8CPU 25CAL Media MSWS 12 ST2S RM Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media MSWS 12 DC2S RM Windows Server 2...

Страница 49: ...f the unified computing environment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Cisco SMARTnet for UCS Servi...

Страница 50: ...se customers Cisco PSS provides partners with access to Cisco s support infrastructure and assets to help them Expand their service portfolios to support the most complex network environments Lower delivery costs Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high value technical support t...

Страница 51: ...llow you to Optimize the uptime performance and efficiency of your UCS Protect your vital business applications by rapidly identifying and addressing issues Strengthen in house expertise through knowledge transfer and mentoring Improve operational efficiency by allowing UCS experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect y...

Страница 52: ...s the risk of any potential liabilities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 29 Table 28 UCS Computing Combined Support Service Product ID PID Servic e Level GSP On Site Descripti...

Страница 53: ...ervices for Cisco Unified Computing System see this URL http www cisco com en US products ps10312 serv_group_home html Table 29 Drive Retention Service Options Service Description Service Program Name Service Level GSP Service Level Product ID PID SMARTnet for UCS Service with Drive Retention UCS DR UCSD7 24x7x4 Onsite CON UCSD7 C220M3LF UCSD7 8x5xNBD Onsite CON UCSD5 C220M3LF SMARTnet for UCS HW ...

Страница 54: ...C220 M3 LFF server For more information about the R42610 rack see RACKS page 72 Table 30 Racks and Rack Options Product ID PID PID Description RACK UCS1 Notes 1 Use these same base PIDs to order spare racks available only as next day replacements Cisco R42610 expansion rack no side panels RACK UCS21 Cisco R42610 standard rack w side panels RACK BLANK 001 Filler panels qty 12 1U plastic toolless RA...

Страница 55: ...TEP ORDER PDU An optional power distribution unit PDU is available from Cisco for the C Series rack servers including the C220 M3 server This PDU is available in a zero rack unit RU style see Table 30 For more information about the PDU see PDUs page 74 Table 31 PDU Options Product ID PID PID Description RP208 30 2P U 2 Zero RU PDU ...

Страница 56: ... on motherboard 2 Drive backplane 11 Standard profile PCIe riser PCIe slot 1 3 SuperCap data cache power backup unit mounting location 12 Low profile PCIe riser PCIe slot 2 4 Cooling fans five 13 Cisco Flexible Flash SD socket SD2 on PCIe riser 2 5 SCU upgrade ROM header RAID key 14 Cisco Flexible Flash SD socket SD1 on PCIe riser 2 6 DIMM slots on motherboard 16 15 Internal USB port FAN1 FAN1 FAN...

Страница 57: ... Figure 7 shows how banks and channels are physically laid out on the motherboard The DIMM slots on the right channels A B C and D are associated with CPU1 while the DIMM slots on the left channels E F G and H are associated with CPU2 The bank 1 blue DIMM slots are always located farther away from a CPU than the corresponding bank 2 black slots Bank 1 slots blue are populated before bank 2 slots b...

Страница 58: ...3 High Density Rack Server Large Form Factor Hard Disk Drive Model 58 SUPPLEMENTAL MATERIAL Figure 7 Physical Layout of CPU DIMM Channels and Banks C1 C2 D1 D2 B2 B1 A2 A1 G1 G2 H2 H1 F2 F1 E1 E2 Front of Server CPU1 CPU2 331707 ...

Страница 59: ...ame bank this will result in less than optimal performance For optimal performance all DIMMs in the same bank should be identical DIMM Capacity RDIMM 4 8 or 16 GB LRDIMM 32 GB UDIMM 4 GB DIMMs in the same channel for example A1 and A2 can have different capacities You cannot mix 32 GB LRDIMMs with any RDIMM or UDIMM You cannot mix 4 GB UDIMMs with any RDIMM or LRIMM For best performance DIMMs in t...

Страница 60: ...late the DIMMs for a CPU according to Table 33 Table 33 DIMM Population Order per CPU DIMMs per CPU Populate CPU 1 Slots Populate CPU 2 Slots 1 A1 E1 2 A1 B1 E1 F1 3 A1 B1 C1 E1 F1 G1 4 A1 B1 C1 D1 E1 F1 G1 H1 61 Notes 1 Not recommended for performance reasons A1 B1 C1 A2 B2 C2 E1 F1 G1 E2 F2 G2 8 A1 B1 C1 D1 A2 B2 C2 D2 E1 F1 G1 H1 E2 F2 G2 H2 ...

Страница 61: ...lating 1600 and 1866 MHz DIMMs for Intel Xeon E5 2600 v2 CPUs and Table 35 when populating 1600 MHz DIMMs for Intel Xeon E5 2600 CPUs Table 34 Recommended Memory Configurations for Intel Xeon E5 2600 v2 CPUs with 1600 and 1866 MHz DIMMs 1 Total System Memory Size CPU 1 DIMMs CPU 2 DIMMs DIMM Max Speed MHz Total DIMMs Blue Slots Bank 1 A1 B1 C1 D1 Black Slots Bank 2 A2 B2 C2 D2 Blue Slots Bank 1 E1...

Страница 62: ... A2 B2 C2 D2 Blue Slots Bank 1 E1 F1 G1 H1 Black Slots Bank 2 E2 F2 G2 H2 32 GB 4x4 GB 4x4 GB 1600 8 2x8 GB 2x8 GB 1600 4 64 GB 4x4 GB 4x4 GB 4x4 GB 4x4 GB 1600 16 4x8 GB 4x8 GB 1600 8 96 GB 4x8 GB 2x8 GB 4x8 GB 2x8 GB 1600 12 3x16 GB 3x16 GB 1600 6 4x8 GB 4x4 GB 4x8 GB 4x4 GB 1600 16 128 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB 1600 16 4x16 GB 4x16 GB 1600 8 192 GB 4x16 GB 2x16 GB 4x16 GB 2x16 GB 1600 12 4...

Страница 63: ...2 GB LRDIMMs run in some cases at a maximum speed of 1333 MHz in 2DPC configurations even though the specified DIMM speed is higher Table 35 Recommended Memory Configurations for Intel Xeon E5 2600 CPUs with 1600 MHz DIMMs 1 Total System Memory Size CPU 1 DIMMs CPU 2 DIMMs DIMM Max Speed MHz Total DIMMs Blue Slots Bank 1 A1 B1 C1 D1 Black Slots Bank 2 A2 B2 C2 D2 Blue Slots Bank 1 E1 F1 G1 H1 Blac...

Страница 64: ... 4 GB 8 32 GB 64 GB 4 x 8 GB 4 32 GB 4 x 8 GB 4 32 GB 64 GB 8 x 4 GB 8 32 GB 8 x 4 GB 8 32 GB 64 GB 1 x 32 GB 1 32 GB 1 x 32 GB 1 32 GB 64 GB 5 x 8 GB 5 40 GB 5 x 8 GB 5 40 GB 80 GB 3 x 16 GB 3 48 GB 3 x 16 GB 3 48 GB 96 GB 6 x 8 GB 6 48 GB 6 x 8 GB 6 48 GB 96 GB 4x8 GB 4x4 GB 8 48 GB 4x8 GB 4x4 GB 8 48 GB 96 GB 7 x 8 GB 7 56 GB 7 x 8 GB 7 56 GB 112 GB 4 x 16 GB 4 64 GB 4 x 16 GB 4 64 GB 128 GB 8 ...

Страница 65: ...server must have the identical manufacturer type speed and size Low voltage DIMMs and standard voltage DIMMs can be mixed in the same server Note that this causes the system BIOS to default to standard voltage operation Performance Mode That is the server cannot operate in Power Saving Mode unless all DIMMs are low voltage DIMMs CPUs that have a maximum memory frequency less than 1333 MHz support ...

Страница 66: ...r slot 2 from Table 8 on page 24 One external drive RAID controller slot 1 or 2 from Table 8 on page 24 One mezzanine RAID controller from Table 7 on page 23 and one external drive RAID controller slot 1 or 2 from Table 7 on page 23 You may also select an appropriate optional RAID configuration listed in Table 8 on page 24 NOTE PCIe slot 2 is not supported for 1 CPU configurations NOTE In 1 CPU co...

Страница 67: ...ntains an Option ROM OPROM for the PCIe slots The server has a finite amount of option ROM with which it can boot up devices Go into the BIOS and disable the OPROM on the PCIe slots not used for booting so that resources are available for the slots that are used for booting An example OPROM BIOS screen is shown in Figure 8 Figure 8 Example BIOS Screen for OPROM ...

Страница 68: ...inout details of the rear port RJ 45 serial port connector are shown in Figure 9 Figure 9 Serial Port Female RJ 45 Connector Pinout 1 2 3 4 5 6 7 8 Pin Serial Port RJ 45 Female Connector Signal RTS Request to Send DTR Data Terminal Ready TxD Transmit Data RxD Receive Data DSR Data Set Ready CTS Clear to Send GND Signal Ground GND Signal Ground ...

Страница 69: ...blanking panel for UCS C Series Server UCSC HS C220M3 Heat Sink for UCS C220 M3 Rack Server1 UCSC AIRBAF C220 Air Baffle Replacement Kit for C220 M3 Server1 N20 MBLIBATT Replacement Lithium Battery for Server Motherboard CR2032 1 UCS RAID BBU Battery Back Up for 92662 UCS RAID CV SC LSI CacheVault Power Module for 9266CV 8i 9271CV 8i 9285CV 8e and 9286CV 8e3 UCSC PSU BLKP Power supply blanking pan...

Страница 70: ... tools Pick and pull cap tool used to pull off the plastic protective cap covering an empty CPU socket and to remove or lift a CPU processor without touching it Pick and place tool used to install a CPU in its socket without damage Must be used each time a CPU is installed in a UCS M3 server Instructions for using this tool set are found at the following link 2 If your server contains an LSI MegaR...

Страница 71: ...used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process Instructions for cleaning are found at the following link http www cisco com en US docs unified_computing ucs c hw C220 install replace html wp1233864 NOTE When you purchase a spare CPU the Pick n Place Toolkit is included CAUTION Use only the thermal grease specified for this server UCS ...

Страница 72: ...10 Rack Specifications Parameter Standard Rack Expansion Rack Dimensions H x W x D 78 74 x 24 x 43 38 in 2000 x 610 x 1102 mm 78 74 x 23 58 x 43 38 in 2000 x 599 x 1102 mm Dimensions H x W x D with packaging 89 x 33 x 47 in 2261 x 838 x 1194 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm Distance from front mounting rail to rear mounting rail 29 2 in 741 mm 29 2 in 741 mm Weight 299 83 lb 136 kg 231 49 l...

Страница 73: ...UCS Cisco UCS C220 M3 High Density Rack Server Large Form Factor Hard Disk Drive Model SUPPLEMENTAL MATERIAL 73 Figure 10 Cisco R42610 Rack Front view door closed Front view door open Front view door removed ...

Страница 74: ... Series PDU in the rack you can replace up to two dozen input power cords with just one The fixed input cord connects to the power source from overhead or under floor distribution Your IT equipment is then powered by PDU outlets in the rack using short easy to manage power cords The C series severs accept the zero rack unit 0RU PDU See Figure 11 Figure 11 Zero Rack Unit PDU PID RP208 30 2P U 2 Cis...

Страница 75: ...ts for a keyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM cable ordering information is listed in Table 39 Figure 12 KVM Cable Table 39 KVM Cable Product ID PID PID Description N20 BKVM KVM cable for B Series Blade Server console port 1 Connector to server front panel 3 VGA connector for a monitor 2 DB 9 serial...

Страница 76: ... socket and two SD sockets as shown in Figure 13 The mounting location for the RAID SuperCap data cache power backup module is also shown Figure 13 Motherboard USB and SD Ports and RAID Card Backup Location 1 SD1 socket 3 USB connector 2 SD2 socket 4 SuperCap module mounting location FAN1 FAN1 FAN1 FAN2 FAN2 FAN2 FAN3 FAN3 FAN3 FAN4 FAN4 FAN4 FAN4 FAN5 FAN5 FAN5 PSU2 PCIe1 PCIe2 PSU1 CPU1 CPU2 SAS...

Страница 77: ...m Side Clearance 1 in 25 mm Rear Clearance 6 in 152 mm Weight Maximum 4 HDDs 2 CPUs 16 DIMMs 2 power supplies 37 1 lbs 16 8 kg Minimum 1 HDD 1 CPU 1 DIMM 1 power supply 28 5 lbs 12 9 kg Bare 0 HDD 0 CPU 0 DIMM 1 power supply 23 4 lbs 10 6 kg Table 41 UCS C220 M3 LFF 450 W AC Power Supply Specifications Description Specification AC input voltage 90 to 264 VAC self ranging 100 to 120 VAC nominal 200...

Страница 78: ...pply Specifications Description Specification AC input voltage 90 to 264 VAC self ranging 100 to 120 VAC nominal 200 to 240 VAC nominal AC input frequency Range 47 to 63 Hz single phase 50 to 60 Hz nominal Maximum AC input current 7 6 A maximum 100 VAC 3 65 A maximum 208 VAC Maximum AC inrush current 11 A peak 35 C 208 VAC Maximum output power for the power supply 650 W Power supply output voltage...

Страница 79: ...tor at this URL https express salire com Go Cisco Cisco UCS Power Calculator aspx Table 43 UCS C240 M3 SFF Power Specifications 930 W DC power supply Description Specification Class RSP1 Input DC input voltage range 40 to 72 VDC self ranging 48 to 60 VDC nominal DC line input current steady state 23 A peak at 48 VDC Output 12 V main power output 930 W 12 V standby power output 30 W Power supply ou...

Страница 80: ...emperature operating 41 to 104 F 5 to 40 C derate the maximum temperature by 1 C per every 305m of altitude above sea level Temperature nonoperating 40 to 149 F 40 to 65 C Humidity RH nonoperating non condensing 10 to 90 Altitude operating 0 to 3 000 m 0 to 10 000 ft Altitude nonoperating 0 to 12 192 m 0 to 40 000 ft Sound Power level Measure A weighted per ISO7779 LWAd Bels Operation at 73 F 23 C...

Страница 81: ...r Description Regulatory Compliance Products should comply with CE Markings per directives 2004 108 EC and 2006 95 EC Safety UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 EMC Emissions 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN...

Страница 82: ...Cisco UCS Cisco UCS C220 M3 High Density Rack Server Large Form Factor Hard Disk Drive Model 82 TECHNICAL SPECIFICATIONS ...

Отзывы: