
Cisco UCS B22 M3 Blade Server
CONFIGURING the SERVER
17
Choose a Mezzanine Adapter
The supported mezzanine adapters in the UCS B22 M3 are listed in
Table 7
.
“Adapter 1” and “Adapter 2” refer to the UCS Manager (UCSM) naming convention for the
adapter slots (this document uses the UCSM naming convention). In the server BIOS and on the
motherboard, the corresponding slots are labeled as “mLOM” and “Mezz 1,” respectively. See
Table 8
.
Table 7 Supported Mezzanine Adapters
Product ID (PID)
PID Description
Connector
Virtual Interface Cards (VICs)
UCSB-MLOM-40G-01
Cisco UCS VIC 1240 modular LOM for M3 blade servers. Plugs into
adapter slot 1 only. It is the only adapter that can be plugged into
the adapter 1 connector.
Adapter 1
UCS-VIC-M82-8P
Cisco UCS VIC 1280 dual 40 Gb capable Virtual Interface Card
Adapter 2
Converged Network Adapters (CNAs)
UCSB-MEZ-QLG-03
Cisco UCS CNA M73KR-Q QLogic Adapter
Adapter 2
UCSB-MEZ-ELX-03
Cisco UCS CNA M73KR-E Emulex Adapter
Adapter 2
Cisco UCS Storage Accelerators
UCSB-F-FIO-785M
Cisco UCS 785 GB MLC Fusion ioDrive2
Adapter 2
UCSB-F-FIO-365M
Cisco UCS 365 GB MLC Fusion-io ioDrive2
Adapter 2
UCSB-F-LSI-400S
LSI 400 GB SLC WarpDrive
Adapter 2
Table 8
Adapter Slot Naming
Server BIOS and Motherboard Slot Naming
UCSM Slot Naming
mLOM (VIC 1240 only)
Adapter 1
Mezz1
Adapter 2