Cisco UCS B22 M3 Скачать руководство пользователя страница 1

C

ISCO

 S

YSTEMS

P

UBLICATION

 H

ISTORY

 

170 W

EST

 T

ASMAN

 D

R

.

 

S

AN

 J

OSE

, CA, 95134

R

EV

 A.11

A

UGUST

 9, 2013

 

WWW

.

CISCO

.

COM

Spec Sheet

Cisco UCS B22 M3

Blade Server

Содержание UCS B22 M3

Страница 1: ...CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV A 11 AUGUST 9 2013 WWW CISCO COM Spec Sheet Cisco UCS B22 M3 Blade Server ...

Страница 2: ...n 36 Recommended DIMM Populations 36 Upgrade and Servicing Related Parts 38 Drive and Blade Server Blanking Panels 38 Adding an Additional CPU with CPU heat sink 38 Motherboard Lithium Battery 38 CPU Removal and Installation pick n place Tool Set 39 Thermal Grease with syringe applicator for CPU to Heatsink Seal 39 Air Baffle Replacement Kit 39 CPU Heat Sink Cleaning Kit 40 Network Connectivity 41...

Страница 3: ... quick deployment of scalable IT infrastructure and Web 2 0 applications The Cisco UCS B22 M3 harnesses the power of the latest Intel Xeon processor E5 2400 product family with expandability to 384 GB of RAM using 32 GB DIMMs 2 hot plug drives and 2 PCIe mezzanine adapter slots for up to 80 Gbps throughput Figure 1 Cisco UCS B22 M3 Blade Server ...

Страница 4: ... your asset information on the tag 7 Network link status LED 2 Blade ejector handle 8 Blade health LED 3 Ejector captive screw 9 Console connector1 Notes 1 For information about the KVM local I O cable that plugs into the console connector a cable is included with every Cisco UCS 5100 Series blade server chassis accessory kit see ORDER OPTIONAL KVM LOCAL I O CABLE on page 32 4 Drive bay 1 10 Reset...

Страница 5: ...32 GB DIMMs I O Mezzanine adapters Adapter slot 1 for Cisco s VIC 1240 adapter which provides Ethernet and Fibre Channel over Ethernet FCoE Adapter slot 2 for various types of Cisco Emulex or QLogic network I O adapters or Cisco UCS Storage Accelerator adapters Storage controller LSI Logic SAS 2002 integrated controller 6 Gbs SAS SATA support RAID 0 and 1 Internal storage devices Up to two optiona...

Страница 6: ...all resolutions less than 1600x1200 256 MB video memory Interfaces Front panel One console connector see ORDER OPTIONAL KVM LOCAL I O CABLE on page 32 Power subsystem Integrated in the Cisco UCS 5100 series blade server chassis Fans Integrated in the Cisco UCS 5100 series blade server chassis Integrated management processor The built in Cisco Integrated Management Controller CIMC GUI or CLI interf...

Страница 7: ... 11 STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES OPTIONAL page 14 STEP 5 CHOOSE ADAPTERS page 16 STEP 6 ORDER A TRUSTED PLATFORM MODULE page 20 STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS page 21 STEP 8 ORDER OPTIONAL INTERNAL USB 2 0 DRIVE page 22 STEP 9 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE page 23 STEP 10 CHOOSE OPERATING SYSTEM MEDIA KIT page 26 STEP 11 CHOOSE SER...

Страница 8: ...elected during product ordering CPU s Memory Disk drives VIC 1240 adapter Emulex or QLogic I O adapters Cisco UCS Storage Accelerators Table 2 PID of the Base UCS B22 M3 Blade Server Product ID PID Description UCSB B22 M3 UCS B22 M3 Blade Server without CPU memory HDD VIC 1240 adapter or mezzanine adapters NOTE Use the steps on the following pages to order the UCS B22 M3 server with the configurab...

Страница 9: ...he table for a given CPU the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock For example Selecting lower speed DIMMs If you use an E4 2470 CPU which can support up to 1600 MHz DIMMs with 1333 MHz DIMMs the DIMMs will be clocked at the lower speed of 1333 MHz Selecting higher speed DIMMs If you use 1600 MHz DIMMs with an E5 2420 CPU which can support up to 1333 MH...

Страница 10: ...twork connectivity options The following restrictions apply A virtual interface card VIC the VIC 1240 must always be installed in the VIC 1240 connector The connectivity options are VIC 1240 installed in VIC 1240 slot adapter 1 slot and no adapter installed in the mezzanine slot adapter 2 slot See Network Connectivity on page 41 for complete information on network connectivity support for a B22 M3...

Страница 11: ...speed 1600 MHz Ranks per DIMM 1 or 2 Operational voltage dual 1 5 or 1 35 V Registered DDR3 ECC registered DIMMs RDIMMs Memory is organized with three memory channels per CPU with up to two DIMMs per channel DPC as shown in Figure 3 Maximum memory capacity is 384 GB with 32 GB DIMMs Figure 3 UCS B22 M3 Memory Organization ...

Страница 12: ...ft error in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because only one of the two populated channels provides data Table 4 Supported DDR3 DIMMs and Memory Mirroring Option Product ID PID P...

Страница 13: ...To run the memory DIMMS at 1600 MHz you need to go into the BIOS or set the policy with UCSM service profile to run in Performance Mode This forces the DIMMs to operate at 1 5 V and yields 1600 MHz speeds provided The DIMMs are 1600 MHz devices The CPUs chosen support 1600 MHz operation For more information regarding memory see DIMM and CPU Layout on page 34 and DIMM Population on page 36 Table 5 ...

Страница 14: ...y matrix Matrix8 html wp323852 Table 6 Supported Hot Pluggable Sled Mounted HDDs and SSDs Product ID PID PID Description Drive Type Capacity HDDs A03 D1TBSATA 1 TB 6 Gb SATA 7 2K RPM SFF HDD SATA 1 TB UCS HDD900GI2F106 900 GB 6Gb SAS 10K RPM SFF HDD SAS 900 GB A03 D600GA2 600 GB 6 Gb SAS 10K RPM SFF HDD SAS 600 GB A03 D500GC3 500 GB 6 Gb SATA 7 2K RPM SFF HDD SATA 500 GB UCS HDD300GI2F105 300 GB 6...

Страница 15: ... 6 There is no support for mixing of drive types or capacities Caveats If you select two drives they must be identical in type and capacity NOTE The integrated LSI 2002 MegaRAID controller supports hard disk drives HDDs or solid state drives SSDs Write cache is not implemented SSDs are recommended for applications requiring high speed local storage which is an order of magnitude faster than HDDs ...

Страница 16: ...ese Storage Accelerator adapters are designed specifically for the Cisco UCS B series M3 blades servers and integrate seamlessly to allow improvement in performance and relief of I O bottlenecks NOTE There are two slots on the server Adapter slot 2 accommodates Em ulex or QLogic I O adapters or Cisco UCS Storage Accelerators and adapter slot 1 is a dedicated slot for the VIC 1240 adapter only Tabl...

Страница 17: ...co UCS VIC 1240 modular LOM for M3 blade servers Plugs into adapter slot 1 only It is the only adapter that can be plugged into the adapter 1 connector Adapter 1 UCS VIC M82 8P Cisco UCS VIC 1280 dual 40 Gb capable Virtual Interface Card Adapter 2 Converged Network Adapters CNAs UCSB MEZ QLG 03 Cisco UCS CNA M73KR Q QLogic Adapter Adapter 2 UCSB MEZ ELX 03 Cisco UCS CNA M73KR E Emulex Adapter Adap...

Страница 18: ...ot 2 Ports Reference 2208XP PIDs UCS IOM 2208XP UCS IOM2208 16FET 2208XP VIC 1240 None 4 x 10 Gb Figure 11 on page 44 2204XP PIDs UCS IOM 2204XP UCS IOM2204 8FET 2204XP VIC 1240 None 2 x 10 Gb Figure 12 on page 45 2104XP PID N20 I6584 2104XP VIC 1240 None 2 x 10 Gb Figure 13 on page 45 Table 10 Supported Adapter1 Combinations Options 2 CPU Configuration Fabric Extender Compatibility Adapter Slot 1...

Страница 19: ...er configuration must always have a VIC 1240 installed in the adapter 1 slot 2204XP PIDs UCS IOM 2204XP UCS IOM2204 8FET 2204XP None Emulex or QLogic I O adapter2 2 x 10 Gb Figure 19 on page 49 2204XP VIC 1240 None 2 x 10 Gb Figure 20 on page 50 2204 XP VIC 1240 Cisco UCS Storage Accelerator 2 x 10 Gb Figure 21 on page 50 2204XP VIC 1240 Emulex or QLogic I O adapter2 4 x 10 Gb Figure 22 on page 51...

Страница 20: ...help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is listed in Table 11 Table 11 Trusted Platform Module Product ID PID P...

Страница 21: ...in Figure 4 Figure 4 SD Locations The SDHC card ordering information is listed in Table 12 Supported Configurations 1 Select one or two Cisco Flexible Flash secure digital card Table 12 Cisco Flexible Flash Secure Digital Cards Product ID PID PID Description UCS SD 16G 16 GB SD Card module for UCS Servers NOTE The SD card transfer rates are Sequential reads 23 MB s Sequential writes 20 MB s 332219...

Страница 22: ...USBFLSH S 4GB 4GB Flash USB Drive shorter length for all servers except C260 NOTE A clearance of 0 950 inches 24 1 mm is required for the USB device to be inserted and removed see the following figure NOTE When the Cisco 4GB USB key is purchased with a server it is pre installed into the internal USB port and held firmly in place with a clip to protect it from shock and vibration during shipment a...

Страница 23: ...nterprise Server SLES 1A SLES 1yr subscription svcs required 0 media SLES 3A SLES 3yr subscription svcs required 0 media UCS SLES TERMS Acceptance of Terms Standalone SLES License for UCS Servers Red Hat Enterprise Linux RHEL 2S 1G 1A RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2S 1G 3A RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL 2S 4G 1A RHEL 2 Socket 4 Guest 1Yr Svcs Required RHEL 2S 4G 3A RHE...

Страница 24: ...r Support Rqd VMW VS5 STD 5A VMware vSphere 5 Standard for 1 Processor 5 Year Support Rqd VMW VS5 ENT 1A VMware vSphere 5 Enterprise for 1 Processor 1 Year Support Rqd VMW VS5 ENT 2A VMware vSphere 5 Enterprise for 1 CPU 2 Yr Support Rqd VMW VS5 ENT 3A VMware vSphere 5 Enterprise for 1 CPU 3 Yr Support Rqd VMW VS5 ENT 4A VMware vSphere 5 Enterprise for 1 Processor 4 Year Support Rqd VMW VS5 ENT 5A...

Страница 25: ... VMW TERMS Acceptance of Terms Standalone VMW License for UCS Servers NOTE For additional information see OS hypervisor support matrix at the following link http www cisco com en US products ps10477 prod_technical_reference_list h tml Table 14 OSs and Value Added Software for 2 CPU servers continued PID Description Product ID PID ...

Страница 26: ...HEL 6 RHEL 6 Recovery Media Only Multilingual SLES 11 SLES 11 media only multilingual MSWS 08R2 STHV RM Windows Svr 2008 R2 ST 1 4CPU 5CAL Media MSWS 08RS ENHV RM Windows Svr 2008 R2 EN 1 8CPU 25CAL Media MSWS 08R2 DCHV RM Windows Svr 2008 R2 DC 1 8CPU 25CAL Media MSWS 12 ST2S RM Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media MSWS 12 DC2S RM Windows Server 2012 Datacenter 2 CPU Unlimited ...

Страница 27: ...of the unified computing environment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Cisco SMARTnet for UCS Serv...

Страница 28: ...rovides partners with access to Cisco s support infrastructure and assets to help them Expand their service portfolios to support the most complex network environments Lower delivery costs Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high value technical support that capitalizes on Cisco...

Страница 29: ... you to Optimize the uptime performance and efficiency of your UCS Protect your vital business applications by rapidly identifying and addressing issues Strengthen in house expertise through knowledge transfer and mentoring Improve operational efficiency by allowing UCS experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect your ...

Страница 30: ... If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 21 Table 20 UCS Computing Combined Support Service Product ID PID Service Level GSP On Site Description CON NCF2 B22M3 NCF2 No CMB SPT SVC 24X7X2 UCS B22 M3 Server CON NCF2P B22M3 NCF2P Yes CMB SPT SVC 24X7X2OS UCS B22 M3 Server...

Страница 31: ...a complete listing of available services for Cisco Unified Computing System see this URL http www cisco com en US products ps10312 serv_group_home html SMARTnet for UCS HW ONLY Drive Retention UCS HW DR UCWD7 24x7x4 Onsite CON UCWD7 B22M3 UCWD5 8x5xNBD Onsite CON UCWD5 B22M3 Table 21 Drive Retention Service Options continued Service Description Service Program Name Service Level GSP Service Level ...

Страница 32: ...eyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM local I O cable ordering information is listed in Table 22 Figure 5 KVM Local I O Cable Table 22 KVM Local I O Cable Product ID PID PID Description N20 BKVM KVM local IO cable for UCS servers console port 1 Connector to server front panel 3 VGA connector for a mon...

Страница 33: ...tes 1 A USB device installed in this connector must have sufficient clearance to easily slide in and out The Cisco USB device clearance is 0 950 inches 24 1 mm which is a sufficient amount of clearance 7 CPU 2 DIMM slots 3 Battery 8 CPU 2 and heat sink 4 CPU 1 and heat sink 9 Modular LOM shown installed 5 CPU 1 DIMM slots 10 Mezzanine adapter connector adapter not shown CPU 1 CPU 2 D1 D0 C1 C0 B1 ...

Страница 34: ...emory channels as follows CPU1 Channels B C and D Bank 0 B0 C0 and D0 blue DIMM slots Bank 1 B1 C1 and D1 black DIMM slots CPU2 Channels F G and H Bank 0 F0 G0 and H0 blue DIMM slots Bank 1 F G1 and H1 black DIMM slots The DIMM and CPU physical layout is shown in Figure 8 The 6 DIMM slots at the left are controlled by CPU 1 and the 6 DIMM slots on the right are controlled by CPU 2 ...

Страница 35: ...Cisco UCS B22 M3 Blade Server SUPPLEMENTAL MATERIAL 35 Figure 8 DIMM and CPU Layout 1 Channels B D for CPU 1 2 Channels F H for CPU 2 CPU 1 CPU 2 D1 D0 C1 C0 B1 B0 F0 F1 G0 G1 H0 H1 2 1 ...

Страница 36: ... 48 96 1600 MHz 16 GB 16 GB 96 192 1600 MHz 4 GB 8 GB 36 72 1600 MHz 4 GB 16 GB 60 GB 120 GB 1600 MHz 8 GB 16 GB 72 GB 144 GB 1600 MHz 32 GB 32 GB 192 GB 384 GB 160 MHz Table 24 4 GB DIMMs Mixed with 8 GB or 16 GB DIMMs Total Memory GB Number of CPUs CPU 1 DIMM Size GB Populated CPU 2 DIMM Size GB Populated B0 B1 C0 C1 D0 D1 F0 F1 G0 G1 H0 H1 12 20 1 4 8 16 none none none none none none none none ...

Страница 37: ... none none 40 56 4 4 4 8 16 none none 4 4 4 8 16 none none 32 4 4 4 4 none none 4 4 4 4 none none 64 96 4 4 4 4 8 16 8 16 4 4 4 4 8 16 8 16 56 72 4 4 4 4 4 8 16 4 4 4 4 4 8 16 Table 24 4 GB DIMMs Mixed with 8 GB or 16 GB DIMMs continued Total Memory GB Number of CPUs CPU 1 DIMM Size GB Populated CPU 2 DIMM Size GB Populated B0 B1 C0 C1 D0 D1 F0 F1 G0 G1 H0 H1 ...

Страница 38: ... and heat sink can be found at the following link http www cisco com en US docs unified_computing ucs hw chassis install b22 html wp1010281 Motherboard Lithium Battery You can order a replacement motherboard battery Installation instructions are found at this link http www cisco com en US docs unified_computing ucs hw chassis install b22 html wp1034829 Table 25 Upgrade and Servicing related Parts ...

Страница 39: ...ent Kit Air baffles are designed to direct airflow through the server to maintain server temperature at a safe operating level The UCS B22 M3 server comes shipped with two identical air baffles covering the DIMM socket areas of the server These baffles must always remain installed during server operation The Air Baffle Replacement Kit includes the two identical air baffles needed for one UCS B22 M...

Страница 40: ...ove the existing thermal compound from the bottom of the heat sink during a CPU replacement process Instructions for cleaning are found at the following link http www cisco com en US docs unified_computing ucs hw chassis install b22 html wp1010281 NOTE When you purchase a spare CPU the CPU cleaning kit is included ...

Страница 41: ...UCS B22 M3 blade server to the Fabric Extenders Figure 9 shows an example configuration where two 2 x 10G KR ports are routed from the VIC 1240 adapter to the Fabric Extender modules and two 2 x 10G KR ports are routed from the mezzanine adapter to the Fabric Extender modules Figure 9 UCS B22 M3 Connections to the Fabric Extenders The server accommodates two types of network I O adapters One is th...

Страница 42: ...stead they provide independent high speed storage controlled by CPU 2 See Table 7 on page 17 for descriptions VIC 1240 Adapter The only adapter that can be plugged in to the VIC 1240 slot is the VIC 1240 a Cisco designed PCIe based adapter that in the UCS B22 M3 server provides up to four depending on the Fabric Extender option chosen 10 Gigabit Data Center Ethernet DCE network interfaces Two port...

Страница 43: ...73KR E QLogic M73KR Q Cisco UCS Storage Accelerators 785 GB MLC Fusion ioDrive2 LSI 400 GB SLC WarpDrive The following sections explain the various I O options that are possible with the different Fabric Extenders Cisco UCS 2208XP 2204XP and 2104XP and the VIC 1240 and mezzanine adapters NOTE In a B22 M3 configured with 2 CPUs if a UCS B22 M3 blade server does not have a VIC 1240 installed the mez...

Страница 44: ... option shown in Figure 11 demonstrates how a 1 CPU server is connected to the Cisco UCS 2208XP Two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The result is 20 Gbps of bandwidth to each Fabric Extender Figure 11 VIC 1240 to UCS 2208XP Fabric Extender no mezzanine adapter Connectivity using the Cisco UCS 2204XP Fabric Extender...

Страница 45: ...XP Fabric Extender The option shown in Figure 13 demonstrates how a 1 CPU server is connected to the Cisco UCS 2104XP One port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender Figure 13 VIC 1240 to UCS 2104XP Fabric Extender no mezzanine adapter ...

Страница 46: ...re 18 demonstrate how the server uses these options Emulex or QLogic I O adapter to 2208XP VIC 1240 to 2208XP VIC 1240 and Cisco UCS Storage Accelerator to 2208XP VIC 1240 and Emulex or QLogic I O adapter to 2208XP VIC 1240 and VIC 1280 to 2208XP In Figure 14 there is no VIC 1240 adapter installed In this case a Cisco Emulex or QLogic I O adapter must be installed in the adapter 2 slot Ports A and...

Страница 47: ...ric Extender Figure 15 Option 2 VIC 1240 to UCS 2208XP Fabric Extender no mezzanine adapter In Figure 16 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The result is 20 Gbps of bandwidth to each Fabric Extender The Cisco UCS Storage Accelerator adapter in the adapter 2 slot has no network connectivity Figure 16 Option 3 VIC 1...

Страница 48: ...e result is 30 Gbps of bandwidth to each Fabric Extender Figure 17 Option 4 VIC 1240 and Emulex or QLogic I O Adapter to UCS 2208XP Fabric Extender In Figure 18 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The VIC 1280 installed in the adapter 2 slot also channels two ports to each of the Fabric Extenders The result is 40 G...

Страница 49: ...strate how the server uses these options Emulex or QLogic I O adapter to 2204XP VIC 1240 to 2204XP VIC 1240 and Cisco UCS Storage Accelerator adapter to 2204XP VIC 1240 and Emulex or QLogic I O adapter to 2204XP VIC 1240 and VIC 1280 to 2204XP In Figure 19 there is no VIC 1240 adapter installed In this case a network adapter must be installed in the adapter 2 slot Ports A and B of the mezzanine ad...

Страница 50: ... each Fabric Extender Figure 20 Option 2 VIC 1240 to UCS 2204XP Fabric Extender no mezzanine adapter In Figure 21 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender The Cisco UCS Storage Accelerator adapter has no network connectivity Figure 21 Option 3 VIC 1240 to UCS 2204X...

Страница 51: ...he result is 20 Gbps of bandwidth to each Fabric Extender Figure 22 Option 4 VIC 1240 and Emulex or QLogic I O Adapter to UCS 2204XP Fabric Extender In Figure 23 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The VIC 1280 installed in the adapter 2 slot also channels one port to each of the Fabric Extenders The result is 20 Gbps...

Страница 52: ...gure 24 one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender The Cisco UCS Storage Accelerator adapter located in the mezzanine connector acts as an independent device controlled by CPU 2 and has no network connectivity Figure 24 VIC 1240 to UCS 2104XP Fabric Extender with Cis...

Страница 53: ...tor aspx Table 26 UCS B22 M3 Dimensions and Weight Parameter Value Height 1 95 in 50 mm Width 8 00 in 203 mm Depth 24 4 in 620 mm Weight Base server weight no HDDs no CPUs no VIC 1240 adapter no mezzanine adapter no memory 9 62 lbs 4 36 kg Minimally configured server 1 HDD 1 CPU a VIC 1240 adapter but no mezzanine adapters 1 DIMM module 12 50 lbs 5 67 kg Fully configured server 2 HDDs 2 CPUs VIC 1...

Страница 54: ...Cisco UCS B22 M3 Blade Server 54 TECHNICAL SPECIFICATIONS ...

Отзывы: