background image

C

ISCO

 S

YSTEMS

P

UBLICATION

 H

ISTORY

 

170 W

EST

 T

ASMAN

 D

R

.

 

S

AN

 J

OSE

, CA, 95134

R

EV

 C.6

M

AY

 27, 2014

 

WWW

.

CISCO

.

COM

Spec Sheet

Cisco UCS B200 M3

Blade Server

Содержание UCS B200 M3

Страница 1: ...CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV C 6 MAY 27 2014 WWW CISCO COM Spec Sheet Cisco UCS B200 M3 Blade Server ...

Страница 2: ...System Board 36 CPUs and DIMMs 37 Physical Layout 37 DIMM Population Rules 39 DIMM Population Order 40 Recommended Memory Configuration 41 Additional DIMM Populations 44 Upgrade and Servicing Related Parts 45 Drive and Blade Server Blanking Panels 45 Upgrading your Server from Intel Xeon E5 2600 to Intel Xeon E5 2600 v2 CPUs or downgrading from Intel Xeon E5 2600 v2 to Intel Xeon E5 2600 CPUs 45 A...

Страница 3: ...h distributed database The enterprise class Cisco UCS B200 M3 blade server extends the capabilities of Cisco s Unified Computing System portfolio in a half width blade form factor The Cisco UCS B200 M3 harnesses the power of the latest Intel Xeon E5 2600 v2 and E5 2600 series processor family CPUs with up to 768 GB of RAM using 32 GB DIMMs 2 drives and up to 80 Gbs throughput connectivity Figure 1...

Страница 4: ...e your asset information on the tag 7 Network link status LED 2 Blade ejector handle 8 Blade health LED 3 Ejector captive screw 9 Console connector1 Notes 1 For information about the KVM local I O cable that plugs into the console connector a cable is included with every Cisco UCS 5100 Series blade server chassis accessory kit see ORDER OPTIONAL KVM LOCAL I O CABLE on page 35 4 Drive bay 1 10 Rese...

Страница 5: ...ssor family CPUs Chipset Intel C600 series chipset Memory 24 total slots for registered ECC DIMMs for up to 768 GB total memory capacity B200 M3 configured with 2 CPUs using 32 GB DIMMs I O Mezzanine adapters One connector for Cisco s VIC 1240 adapter which provides Ethernet and Fibre Channel over Ethernet FCoE One connector for various types of Cisco adapters Emulex or QLogic adapters and Cisco U...

Страница 6: ...utions less than 1600x1200 Up to 256 MB video memory Interfaces Front panel One console connector see ORDER OPTIONAL KVM LOCAL I O CABLE on page 35 Power subsystem Integrated in the Cisco UCS 5100 series blade server chassis Fans Integrated in the Cisco UCS 5100 series blade server chassis Integrated management processor The built in Cisco Integrated Management Controller CIMC GUI or CLI interface...

Страница 7: ...e 12 STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES OPTIONAL page 18 STEP 5 CHOOSE ADAPTERS page 20 STEP 6 ORDER A TRUSTED PLATFORM MODULE page 23 STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS page 24 STEP 8 ORDER OPTIONAL INTERNAL USB 2 0 DRIVE page 25 STEP 9 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE page 26 STEP 10 CHOOSE OPERATING SYSTEM MEDIA KIT page 29 STEP 11 CHOOSE SE...

Страница 8: ...s Cisco adapters such as the VIC 1240 VIC 1280 and Port Expander for VIC 1240 Emulex and QLogic network adapters Cisco UCS Storage Accelerators such as the Fusion io and LSI Logic adapter Table 2 PID of the Base UCS B200 M3 Blade Server Product ID PID Description UCSB B200 M3 UCS B200 M3 Blade Server w o CPU memory HDD VIC 1240 adapter or mezzanine adapters NOTE Use the steps on the following page...

Страница 9: ...DR3 DIMM Clock Support MHz 1 Intel Xeon E5 2600 v2 UCS CPU E52697B E5 2697 v2 2 70 130W 30 12 8 GT s 1866 UCS CPU E52695B E5 2695 v2 2 40 115 30 12 8 GT s 1866 UCS CPU E52690B E5 2690 v2 3 00 130 25 10 8 GT s 1866 UCS CPU E52680B E5 2680 v2 2 80 115 25 10 8 GT s 1866 UCS CPU E52670B E5 2670 v2 2 50 115 25 10 8 GT s 1866 UCS CPU E52667B E5 2667 v2 3 30 130 25 8 8 GT s 1866 UCS CPU E52660B E5 2660 v...

Страница 10: ...20 95 20 8 8 GT s 1600 UCS CPU E5 2658 E5 2658 2 10 95 20 8 8 GT s 1600 UCS CPU E5 2650 E5 2650 2 00 95 20 8 8 GT s 1600 UCS CPU E5 2650L E5 2650L 1 80 70 20 8 8 GT s 1600 UCS CPU E5 2640 E5 2640 2 50 95 15 6 7 2 GT s 1333 UCS CPU E5 2637 E5 2637 3 00 80 5 2 8 GT s 1600 UCS CPU E5 2630 E5 2630 2 30 95 15 6 7 2 GT s 1333 UCS CPU E5 2630L E5 2630L 2 00 60 15 6 7 2 GT s 1333 UCS CPU E5 2620 E5 2620 2...

Страница 11: ...slot and a Port Expander Card for VIC 1240 installed in the mezzanine slot See NEBS Compliance on page 48 for complete information on network connectivity support for a B200 M3 configured with 1 CPU or 2 CPUs For optimal performance select DIMMs with the highest clock speed for a given processor System speed is dependent on how many DIMMs are populated per channel See Table 7 on page 16 for detail...

Страница 12: ...r DIMM 1 2 or 4 Operational voltage 1 35 or 1 5 V Registered DDR3 ECC registered DIMMs RDIMMs or load reduced DIMMS LRDIMMS Memory is organized with four memory channels per CPU with up to three DIMMs per channel DPC as shown in Figure 3 Maximum memory capacity is 768 GB B200 M3 configured with 2 CPUs with 32 GB DIMMs Figure 3 UCS B200 M3 Memory Organization ...

Страница 13: ...e only one of the two populated channels provides data Table 4 Supported DDR3 DIMMs and Memory Mirroring Option Product ID PID PID Description Voltage Ranks DIMM DIMM Options1 Notes 1 1866 MHz DIMMs are supported only with Intel Xeon E5 2600 v2 CPUs UCS ML 1X324RY A 32 GB DDR3 1600 MHz LRDIMM PC3 12800 4R x4 1 35V 1 5 1 35 V2 2 Dual voltage DIMM operates at 1 5 V with BIOS is set for memory perfor...

Страница 14: ...able 5 Select the memory mirroring option N01 MMIRROR as shown in Table 4 on page 13 Table 5 DIMM Placement With Memory Mirroring B200 M3 configured with 1 CPU Number of DIMMs per CPU DIMM Placement in Banks with memory mirroring implemented CPU 1 2 2 DIMMs in Bank 0 A0 B0 4 4 DIMMs in Bank 0 A0 B0 C0 D0 61 Notes 1 Not recommended for performance reasons 3 DIMMs in Bank 0 A0 B0 C0 3 DIMMs in Bank ...

Страница 15: ...g implemented CPU 1 CPU 2 2 2 DIMMs in Bank 0 A0 B0 2 DIMMs in Bank 0 E0 F0 4 4 DIMMs in Bank 0 A0 B0 C0 D0 4 DIMMs in Bank 0 E0 F0 G0 H0 61 Notes 1 Not recommended for performance reasons 3 DIMMs in Bank 0 A0 B0 C0 3 DIMMs in Bank 1 A1 B1 C1 3 DIMMs in Bank 0 E0 F0 G0 3 DIMMs in Bank 1 E1 F1 G1 8 4 DIMMs in Bank 0 A0 B0 C0 D0 4 DIMMs in Bank 1 A1 B1 C1 D1 4 DIMMs in Bank 0 E0 F0 G0 H0 4 DIMMs in ...

Страница 16: ...s Voltages Voltages Voltages Voltages Voltages 1 3 V 1 5 V 1 3 V 1 5 V 1 3 V 1 5 V 1 3 V 1 5 V 1 3 V 1 5 V 1 3 V 1 5 V 1333 DIMM 1DPC 1333 1333 1333 1333 1333 1333 1333 1333 1333 1333 1333 1333 2DPC 1333 1333 1333 1333 1333 1333 1333 1333 1333 1333 1333 1333 3DPC 1066 1066 NA1 Notes 1 NA not applicable 1066 1066 1066 NA1 1066 1066 1066 NA1 1066 1600 DIMM 1DPC 1333 1333 1333 1333 16002 2 These DIMM...

Страница 17: ... the DIMM supports this change the BIOS setting to power savings mode With 3 RDIMMs populated per channel memory always runs at 1 5 V regardless if the BIOS setting is power savings mode 1 35 V or performance mode 1 5 V With 3 LRDIMMs populated per channel memory can operate at 1 5 V or 1 35 V depending on the BIOS setting For more information regarding memory see CPUs and DIMMs on page 37 ...

Страница 18: ...Ds and SSDs Product ID PID PID Description Drive Type Capacity HDDs A03 D1TBSATA 1 TB 6 Gb SATA 7 2K RPM SFF HDD SATA 1 TB A03 D500GC3 500 GB 6 Gb SATA 7 2K RPM SFF HDD SATA 500 GB UCS HDD900GI2F106 900 GB 6 Gb SAS 10K RPM SFF HDD SAS 900 GB A03 D600GA2 600 GB 6 Gb SAS 10K RPM SFF HDD SAS 600 GB UCS HDD300GI2F105 300 GB 6 Gb SAS 15K RPM SFF HDD SAS 300 GB A03 D300GA2 300 GB 6 Gb SAS 10K RPM SFF HD...

Страница 19: ...m Table 8 There is no support for mixing of drive types or capacities Caveats If you select two drives they must be identical in type and capacity NOTE The integrated RAID controller supports hard disk drives HDDs or solid state drives SSDs Write cache is not implemented SSDs are recommended for applications requiring high speed local storage which is an order of magnitude faster than HDDs ...

Страница 20: ...ine adapters in the UCS B200 M3 are listed in Table 9 NOTE There are two slots on the server One accommodates Cisco Emulex and QLogic I O adapters or Cisco Storage Accelerator adapters as well as other options and one is a dedicated slot for the VIC 1240 adapter only Table 9 shows which adapters plug into each of the two slots Only the VIC 1240 adapter plugs into the VIC 1240 adapter slot All othe...

Страница 21: ...ander Card for VIC 1240 This is a hardware option to enable an additional 4 ports of the VIC 1240 bringing the total capability of the VIC 1240 to dual 4 x 10 GbE Mezzanine Table 10 Supported VIC 1240 and Mezzanine Adapter Configurations Fabric Extender Compatibility Adapter in VIC 1240 Slot Adapter in Mezzanine Slot Ports Reference 2208XP PIDs UCS IOM 2208XP UCS IOM2208 16FET 2208XP VIC 1240 None...

Страница 22: ... IOM2208 16FET 2208XP VIC 1240 None 4 x 10 Gb Figure 15 on page 56 2208XP VIC 1240 VIC 1280 8 x 10 Gb Figure 16 on page 57 2208XP VIC 1240 Emulex or QLogic I O adapter or Cisco UCS Storage Accelerator 6 x 10 Gb 4 x 10 Gb Figure 17 on page 57 2208XP VIC 1240 Port Expander Card for VIC 1240 8 x 10 Gb Figure 18 on page 58 2208XP None Emulex or QLogic I O adapter1 Notes 1 Specifically the UCSB MEZ QLG...

Страница 23: ... help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is listed in Table 12 Table 12 Trusted Platform Module Product ID PID ...

Страница 24: ...ide of the server The SDHC card ordering information is listed in Table 13 Supported Configurations 1 Select one or two Cisco Flexible Flash secure digital cards NOTE Dual card support mirroring is supported with UCS Manager 2 2 x and later Table 13 Supported Configurations Secure Digital Card s Product ID PID PID Description UCS SD 16G 16GB SD Card module for UCS Servers ...

Страница 25: ...tion UCS USBFLSH S 4GB 4GB Flash USB Drive shorter for all M3 servers NOTE A clearance of 0 950 inches 24 1 mm is required for the USB device to be inserted and removed see the following figure NOTE When the Cisco 4GB USB key is purchased with a server it is pre installed into the internal USB port and held firmly in place with a clip to protect it from shock and vibration during shipment and tran...

Страница 26: ...e Srvr 1 2 CPU 1 Phys 5yr Support Reqd SLES SVR 2S UG 1A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 1yr Support Reqd SLES SVR 2S UG 3A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 3yr Support Reqd SLES SVR 2S UG 5A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 5yr Support Reqd SLES SHA 2S 1A SUSE Linux High Availability Ext 1 2 CPU 1yr Support Reqd SLES SHA 2S 3A SUSE Linux High Availability Ext 1 2 CPU 3...

Страница 27: ... SE 4C BMC BladeLogic Standard Edition 4 Cores Support Required BMC SE 6C BMC BladeLogic Standard Edition 6 Cores Support Required BMC SE 8C BMC BladeLogic Standard Edition 8 Cores Support Required BMC SE 10C BMC BladeLogic Standard Edition 10 Cores Support Required BMC AE 4C BMC BladeLogic Advanced Edition 4 Cores Support Required BMC AE 6C BMC BladeLogic Advanced Edition 6 Cores Support Required...

Страница 28: ...se Plus for 1 Processor 1 Year Support Rqd VMW VS5 ENTP 2A VMware vSphere 5 Enterprise Plus for 1 CPU 2 Yr Support Rqd VMW VS5 ENTP 3A VMware vSphere 5 Enterprise Plus for 1 Processor 3 Year Support Rqd VMW VS5 ENTP 4A VMware vSphere 5 Enterprise Plus for 1 Processor 4 Year Support Rqd VMW VS5 ENTP 5A VMware vSphere 5 Enterprise Plus for 1 Processor 5 Year Support Rqd VMW VC5 STD 1A VMware vCenter...

Страница 29: ...edia listed in Table 16 Table 16 OS Media Product ID PID PID Description RHEL 6 RHEL 6 Recovery Media Only Multilingual SLES 11 SLES 11 media only multilingual MSWS 08R2 STHV RM Windows Svr 2008 R2 ST 1 4CPU 5CAL Media MSWS 08R2 ENHV RM Windows Svr 2008 R2 EN 1 8CPU 25CAL Media MSWS 08R2 DCHV RM Windows Svr 2008 R2 DC 1 8CPU 25CAL Media ...

Страница 30: ...ronment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Unified Computing Support Service includes flexible hard...

Страница 31: ...ovides partners with access to Cisco s support infrastructure and assets to help them Expand their service portfolios to support the most complex network environments Lower delivery costs Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high value technical support that capitalizes on Cisco ...

Страница 32: ... performance and efficiency of your UCS Protect your vital business applications by rapidly identifying and addressing issues Strengthen in house expertise through knowledge transfer and mentoring Improve operational efficiency by allowing UCS experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect your operations Table 19 Partner...

Страница 33: ...abilities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 22 Table 21 UCS Computing Combined Support Service Product ID PID Service Level GSP On Site Description CON NCF2 B200M3 NCF2 No CMB ...

Страница 34: ... Computing System see this URL http www cisco com en US products ps10312 serv_group_home html Table 22 Drive Retention Service Options Service Description Service Program Name Service Level GSP Service Level Product ID PID UCS Support Service With Drive Retention UC SUPP DR UCSD5 8x5xNBD Onsite CON UCSD5 B200M3 UCSD7 24x7x4 Onsite CON UCSD7 B200M3 UCS Warranty Plus With Drive Retention UC PLUS DR ...

Страница 35: ...eyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM local I O cable ordering information is listed in Table 23 Figure 4 KVM Local I O Cable Table 23 KVM Local I O Cable Product ID PID PID Description N20 BKVM KVM local IO cable for UCS servers console port 1 Connector to server front panel 3 VGA connector for a mon...

Страница 36: ...ed in this connector must have sufficient clearance to easily slide in and out The Cisco USB device clearance is 0 950 inches 24 1 mm which is a sufficient amount of clearance 6 Diagnostic button 3 Battery 7 VIC 1240 adapter shown installed 4 CPU and heat sink 8 Mezzanine adapter slot mezzanine adapter not shown installed CPU 1 CPU 2 C0 C1 C2 D0 D1 D2 B2 B1 B0 A2 A1 A0 E0 E0 E1 E1 E2 E2 F0 F0 F1 F...

Страница 37: ...wn in Figure 6 Figure 6 UCS B200 M3 Memory Organization Each CPU controls four memory channels as follows CPU1 Channels A B C and D Bank 0 A0 B0 C0 and D0 blue DIMM slots Bank 1 A1 B1 C1 and D1 black DIMM slots Bank 2 A2 B2 C2 and D2 white DIMM slots CPU2 Channels E F G and H Bank 0 E0 F0 G0 and H0 blue DIMM slots ...

Страница 38: ...sical layout is shown in Figure 7 The 12 DIMM slots at the left are controlled by CPU 1 and the 12 DIMM slots on the right are controlled by CPU 2 Figure 7 DIMM and CPU Layout 1 Channels A D for CPU 1 2 Channels E H for CPU 2 331374 CPU1 CPU2 C0 C1 C2 D0 D1 D2 B2 B1 B0 A2 A1 A0 E0 E0 E1 E1 E2 E2 F0 F0 F1 F1 F2 F2 E0 E1 E2 F0 F1 F2 H2 H1 H0 G2 G1 G0 1 1 2 2 ...

Страница 39: ...e Same Channel DIMMs in the Same Bank1 Notes 1 Although you can have different DIMM capacities in the same bank this will result in less than optimal performance For optimal performance all DIMMs in the same bank should be identical DIMM Capacity RDIMM 16 8 or 4 GB LRDIMM 32 GB DIMMs in the same channel for example A0 A1 A2 can have different capacities You cannot mix 32 GB LRDIMMs with any RDIMM ...

Страница 40: ...on Order per CPU DIMMs per CPU Populate CPU 1 Slots Populate CPU 2 Slots 1 A0 E0 2 A0 B0 E0 F0 3 A0 B0 C0 E0 F0 G0 4 A0 B0 C0 D0 E0 F0 G0 H0 61 Notes 1 Not recommended for performance reasons A0 B0 C0 A1 B1 C1 E0 F0 G0 E1 F1 G1 8 A0 B0 C0 D0 A1 B1 C1 D1 E0 F0 G0 H0 E1 F1 G1 H1 12 A0 B0 C0 D0 A1 B1 C1 D1 A2 B2 C2 D2 E0 F0 G0 H0 E1 F1 G1 H1 E2 F2 G2 H2 ...

Страница 41: ...6 and 1600 MHz DIMMs for Intel Xeon E5 2600 v2 CPUs and Table 27 on page 42 when populating 1600 MHz DIMMs for Intel Xeon E5 2600 CPUs Table 26 Recommended Memory Configurations for Intel Xeon E5 2600 v2 CPUs with 1866 and 1600 MHz DIMMs 1 Total System Memory Size CPU 1 DIMMs CPU 2 DIMMs DIMM Max Speed MHz Total DIMMs Blue Slots Bank 0 A0 B0 C0 D0 Black Slots Bank 1 A1 B1 C1 D1 White Slots Bank 2 ...

Страница 42: ... 1333 MHz Table 27 Recommended Memory Configurations for Intel Xeon E5 2600 CPUs with 1600 MHz DIMMs 1 Total System Memory Size CPU 1 DIMMs CPU 2 DIMMs DIMM Max Speed MHz Total DIMMs Blue Slots Bank 0 A0 B0 C0 D0 Black Slots Bank 1 A1 B1 C1 D1 White Slots Bank 2 A2 B2 C2 D2 Blue Slots Bank 0 E0 F0 G0 H0 Black Slots Bank 1 E1 F1 G1 H1 White Slots Bank 2 E2 F2 G2 H2 32 GB 4x4 GB 4x4 GB 1600 8 2x8 GB...

Страница 43: ...16 GB 4x16 GB 1600 16 4 x 32 GB 4 x 32 GB 1600 8 384 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 1333 24 512 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 1333 16 768 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 1066 24 Notes 1 Rows marked in yellow indicate best performance Table 27 Recommended Memory Configurations for Intel Xeon E5 2600 CPUs with 1600 MHz DIMMs 1 Total System Memory Size CPU ...

Страница 44: ...32 GB 4 x 8 GB 4 32 GB 64 GB 8 x 4 GB 8 32 GB 8 x 4 GB 8 32 GB 64 GB 1 x 32 GB 1 32 GB 1 x 32 GB 1 32 GB 64 GB 5 x 8 GB 5 40 GB 5 x 8 GB 5 40 GB 80 GB 3 x 16 GB 3 48 GB 3 x 16 GB 3 48 GB 96 GB 6 x 8 GB 6 48 GB 6 x 8 GB 6 48 GB 96 GB 4x8 GB 4x4 GB 8 48 GB 4x8 GB 4x4 GB 8 48 GB 96 GB 7 x 8 GB 7 56 GB 7 x 8 GB 7 56 GB 112 GB 4 x 16 GB 4 64 GB 4 x 16 GB 4 64 GB 128 GB 8 x 8 GB 8 64 GB 8 x 8 GB 8 64 GB...

Страница 45: ... docs unified_computing ucs hw CPU IVB install IVB B html Table 29 Upgrade and Servicing related Parts for UCS B200 M3 Server Spare Product ID PID Description N20 BBLKD 2 5 inch HDD Blanking Panel1 Notes 1 This part is included configured with your UCS server in some cases as determined by the configuration of your server N20 CBLKB1 Blade slot blanking panel for UCS 5108 single slot2 UCSB HS 01 EP...

Страница 46: ... with syringe applicator for CPU to Heatsink Seal Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink Instructions for applying thermal grease are found at http www cisco com en US docs unified_computing ucs hw chassis install B200M3 html wp1070500 NOTE When you purchase a spare CPU the Pick n Place Toolkit is included CAUTION Use only the thermal grea...

Страница 47: ...ne UCS B200 M3 server For instructions on how to remove and replace the air baffles see the following link http www cisco com en US docs unified_computing ucs hw chassis install B200M3 html wp1034378 CPU Heat Sink Cleaning Kit The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process Instructions for cleaning are found at the...

Страница 48: ...CPU E52658B Up to two CPUs Intel Xeon E5 2658 2 10 GHz 95W 8C 20MB Cache UCS CPU E5 2658 DIMMs Up to 24 8 GB DIMMs 1666MHz UCS MR 1X082RY A Up to 24 16 GB DIMMS 1666MHz UCS MR 1X162RY A Up to 24 8 GB DIMMs 1866MHz UCS MR 1X082RZ A Up to 24 16 GB DIMMS 1866MHz UCS MR 1X162RZ A RAID Controller Integrated RAID HDDs Up to two 300 GB 15K RPM SAS drives 600GB maximum total capacity UCS HDD300GI2F105 Up ...

Страница 49: ...ane connects the UCS B200 M3 blade server to the Fabric Extenders Figure 8 shows an example configuration where 2 x 10G KR ports are routed from the VIC 1240 adapter to the Fabric Extender modules and the remaining 2 x 10G KR ports are routed from the mezzanine adapter to the Fabric Extender modules Figure 8 UCS B200 M3 Connections to the Fabric Extenders The server accommodates two types of netwo...

Страница 50: ...r option chosen see Table 11 on page 22 QLogic and Emulex adapters Cisco Storage Accelerators These flash storage devices do not have network connectivity instead they provide independent high speed storage controlled by CPU 2 See Table 9 on page 20 for descriptions VIC 1240 Adapter The only adapter that can be plugged in to the VIC 1240 slot is the VIC 1240 a Cisco designed PCIe based adapter tha...

Страница 51: ...for port expansion otherwise they are unused Mezzanine Adapters There are multiple options for the mezzanine slot I O based PCIe adapters such as network adapters or Cisco Storage Accelerator adapters such as Fusion io and LSI cache cards Specific examples of mezzanine adapters are Cisco adapters VIC 1240 VIC 1280 Port Expander Card for VIC 1240 Emulex or QLogic I O adapters Emulex M73KR E NOTE In...

Страница 52: ...red with 1 CPU is the Cisco UCS Port Expander Card for VIC 1240 and the VIC 1240 is always required to be installed in the VIC 1240 slot Connectivity using the Cisco UCS 2208XP Fabric Extender The Cisco UCS 2208XP is the second generation Fabric Extender and shares the same form factor as the current UCS 2100 series The 2208XP is backwards compatible with the UCS 5108 Blade server chassis The opti...

Страница 53: ... for VIC 1240 to UCS 2208XP Fabric Extender Connectivity using the Cisco UCS 2204XP Fabric Extender The Cisco UCS 2204XP is a second generation Fabric Extender and shares the same form factor as the current UCS 2100 series The 2204XP is backwards compatible with the UCS 5108 Blade serve chassis The options shown in Figure 12 and Figure 13 demonstrate how the server uses these options VIC 1240 to 2...

Страница 54: ...eled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The Port Expander Card for VIC 1240 installed in the mezzanine slot acts as a pass through device to channel one port to each of the Fabric Extenders The result is 20 Gbps of bandwidth to each Fabric Extender Figure 13 Option 2 VIC 1240 and Port Expander Card for VIC 1240 to UCS 2204XP Fabric Extender ...

Страница 55: ...strates how the UCS B200 M3 blade serves connects to a UCS 2104XP Fabric Extender In Figure 14 one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender Figure 14 Option 1 VIC 1240 to UCS 2104XP Fabric Extender no mezzanine adapter ...

Страница 56: ...and VIC 1280 to 2208XP VIC 1240 and QLogic or Emulex I O adapter to 2208XP VIC 1240 plus Port Expander Card for VIC 1240 to 2208XP QLogic or Emulex I O adapter to 2208XP In Figure 15 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The result is 20 Gbps of bandwidth to each Fabric Extender Figure 15 Option 1 VIC 1240 to UCS 220...

Страница 57: ... is 40 Gbps of bandwidth to each Fabric Extender Figure 16 Option 2 VIC 1240 and VIC 1280 to UCS 2208XP Fabric Extender In Figure 17 two ports from the VIC 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The adapter installed in the mezzanine slot also channels one port to each of the Fabric Extenders The result is 30 Gbps of bandwidth to each Fabri...

Страница 58: ...rts to each of the Fabric Extenders The result is 40 Gbps of bandwidth to each Fabric Extender Figure 18 Option 4 VIC 1240 and Port Expander Card for VIC 1240 to UCS 2208XP Fabric Extender In Figure 19 there is no VIC 1240 adapter installed In this case a network adapter must be installed in the mezzanine slot Port A and B of the mezzanine adapter connect to the Fabric Extenders providing 10 Gbps ...

Страница 59: ...04XP VIC 1240 and Cisco QLogic or Emulex I O adapter to 2204XP VIC 1240 plus Port Expander Card for VIC 1240 to 2204XP QLogic or Emulex I O adapter to 2204XP In Figure 20 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender Figure 20 Option 1 VIC 1240 to UCS 2204XP Fabric Exte...

Страница 60: ... is 20 Gbps of bandwidth to each Fabric Extender Figure 21 Option 2 VIC 1240 and VIC 1280 to UCS 2204XP Fabric Extender In Figure 22 one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The adapter installed in the mezzanine slot also channels one port to each of the Fabric Extenders The result is 20 Gbps of bandwidth to each Fabric E...

Страница 61: ...t to each of the Fabric Extenders The result is 20 Gbps of bandwidth to each Fabric Extender Figure 23 Option 4 VIC 1240 and Port Expander Card for VIC 1240 to UCS 2204XP Fabric Extender In Figure 24 there is no VIC 1240 adapter installed In this case a network adapter must be installed in the mezzanine slot Port A and B of the mezzanine adapter connect to the Fabric Extenders providing 10 Gbps pe...

Страница 62: ...P Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender With this option no adapter is located in the mezzanine connector Figure 25 Option 1 VIC 1240 to UCS 2104XP Fabric Extender no mezzanine adapter In Figure 26 one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender...

Страница 63: ...sco UCS Power Calculator aspx Table 31 UCS B200 M3 Dimensions and Weight Parameter Value Height 1 95 in 50 mm Width 8 00 in 203 mm Depth 24 4 in 620 mm Weight Base server weight no CPUs no HDDs no mezzanine adapters or memory 9 62 lbs 4 36 kg Minimally configured server 1 HDD 2 CPUs a VIC 1240 but no mezzanine adapter 12 50 lbs 5 67 kg Fully configured server 2 HDDs 2 CPUs all memory VIC 1240 and ...

Страница 64: ...Cisco UCS B200 M3 Blade Server 64 TECHNICAL SPECIFICATIONS ...

Отзывы: