background image

Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide

First Published:

2018-08-14

Last Modified:

2018-11-07

Americas Headquarters

Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000

800 553-NETS (6387)

Fax: 408 527-0883

Содержание UCS 6454

Страница 1: ...ardware Installation Guide First Published 2018 08 14 Last Modified 2018 11 07 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Страница 2: ... 2018 Cisco Systems Inc All rights reserved ...

Страница 3: ...EDs 8 L1 and L2 Port LEDs 8 Supported Transceivers 8 SFP 1 Gigabit Transceivers 9 SFP Transceivers and SFP Copper Cables 9 QSFP Transceivers and Cables 11 SFP Fibre Channel Transceivers 12 Installing the Cisco UCS Fabric Interconnect 15 C H A P T E R 2 Preparing for Installation 15 Considerations and Warnings 15 Installation Options 16 Airflow Considerations 16 Fabric Interconnect Weight 16 Instal...

Страница 4: ...g to the Console Port 31 Connecting the Management Port 33 Connecting to an SFP28 Ethernet or Fibre Channel Port 33 Installing or Removing Cables into SFP Transceivers 33 Installing a Transceiver 33 Removing a Transceiver 34 Installing or Removing Cables into SFP28 Trancsceivers 35 Installing a Cable into an SFP28 Transceiver 35 Removing a Cable from a Transceiver 35 Maintaining SFP28 Transceivers...

Страница 5: ...le 48 Console Port 48 Supported AC Power Cords and Plugs 49 Argentina 49 Australia and New Zealand 50 Peoples Republic of China 50 Europe 51 India South Africa and United Arab Emirates 51 Israel 52 Italy 52 North America 53 Switzerland 54 Taiwan 54 United Kingdom 55 Cabinet Jumper Power Cords 55 Site Planning and Maintenance Records 57 C H A P T E R 7 Site Preparation Checklist 57 Contact and Site...

Страница 6: ...Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide vi Contents ...

Страница 7: ...ge all Cisco UCS elements The fabric interconnect supports 10 25 Gigabit ports in the fabric with 40 100 Gigabit uplink ports High availability can be achieved when a Cisco UCS 6454 Fabric Interconnect is connected to another Cisco UCS 6454 Fabric Interconnect through the L1 or L2 port on each device Cisco UCS 6454 Fabric Interconnect The Cisco UCS 6454 Fabric Interconnect is a 1 RU top of rack sw...

Страница 8: ...nd four fans Two of the fans provide front to rear airflow Figure 2 Cisco UCS 6454 Fabric Interconnect Front View Fans 1 through 4 numbered left to right when facing the front of the chassis 2 Power supply and power cord connector 1 L1 port L2 port RJ45 console USB port and LEDs 3 Ports on the Cisco UCS 6454 Fabric Interconnect The ports on the Cisco UCS 6454 Fabric Interconnect can be configured ...

Страница 9: ...bles 96 40G to 4 x 10G breakout cables QSA Port 13 and 14 do not support 40G to 10G breakout 48 32 Number of fixed 10 GB Interfaces 8 16 48 32 Number of Unified Ports 10 25 Gbps or 8 16 32 Gbps FC 1 10 Gbps or 4 8 16 Gbps FC 1 10 Gbps or 1 2 4 8 Gbps FC 1 10 Gbps or 1 2 4 8 Gbps FC Unified Port Speeds Six 40 100 Gigabit ports 24 32 Number of 40 Gbps ports Ports 1 8 Ports 1 16 None Ports 1 48 Ports...

Страница 10: ...s can operate as 10 25 Gbps Ethernet or 8 16 32 Gbps Fibre Channel FC ports are converted in groups of 4 ports by the first 4 ports port 1 to 4 or the first 8 ports port 1 to 8 For more information on how to configure the port modes refer to Configuring Port Modes for a 6454 Fabric Interconnect in the Cisco UCS Network Management Guide Release 4 0 1 Uplink Ports 49 54 Each port can operate as eith...

Страница 11: ...connect Front View Power supplies have two LEDs one for power status and one for a failure condition Green power on LED 2 Amber fault or Error LED 1 Description State LED Power supply is on and functioning properly Solid green Power on LED 3 3 V voltage standby VSB is on but the power supply is not powering up the Fabric Interconnect Blinking green There is no AC power to the power supply Off Powe...

Страница 12: ...454 Fabric Interconnect fan modules The UCS 6332 and UCS 6454 Fabric Interconnect use the same model fans UCS FAN 6332 HA Ports and LEDs The Cisco UCS 6454 Fabric Interconnect has L1 L2 high availability ports network management port console port and a USB port that are shown in Figure 5 For L1 and L2 ports the maximum length of Ethernet CAT5e or CAT6 cable is 100 meters Figure 5 HA Ports and LEDs...

Страница 13: ... Off System fault On Amber Power shut down by software Solid on Red Secure boot validation has failed Blinking Management Port LEDs The status of the management ports is listed below Description LED State LED Position No link Off Left Physical link Solid green No activity Off Right Activity Blinking green System Environment LEDs The system environment LED states are listed below Description LED St...

Страница 14: ...ink Off Left Physical link Solid green Left No activity Off Right Activity Blinking green Right Supported Transceivers The Cisco UCS 6454 Fabric Interconnect support SFP28 Ethernet transceivers SFP transceivers SFP28 transceivers SFP28 copper twinax cables with integrated transceivers SFP Fibre Channel transceivers QSFP transceivers QSFP28 transceivers and QSFP cables Except where noted both the C...

Страница 15: ...Cables The enhanced SFP 10 Gigabit Ethernet transceiver module is a bidirectional device with a transmitter and receiver in the same physical package It has a 20 pin connector on the electrical interface and duplex LC connector on the optical interface Table 3 Supported Transceivers Description Product ID 10GBASE SR SFP module multimode fiber MMF SFP 10G SR 10GBASE SR SFP module multimode fiber MM...

Страница 16: ... 25GBASE CR1 Copper Cable 2 meter SFP H25G AOC2M 25GBASE CR1 Copper Cable 3 meter SFP H25G AOC3M Supported 6454 Fabric Interconnect 10 Gb Cables 10GBASE CU SFP cable 1 meter passive SFP H10GB CU1M 10GBASE CU SFP cable 2 meter passive SFP H10GB CU2M 10GBASE CU SFP cable 3 meter passive SFP H10GB CU3M 10GBASE CU SFP cable 5 meter passive SFP H10GB CU5M 10GBASE CU SFP cable 7 meter active SFP H10GB A...

Страница 17: ...isco 40GBASE LR4 QSFP transceiver module for SMF duplex LC connector QSFP 40G LR4 Cisco 40GBASE LR4 QSFP transceiver module for SMF duplex LC connector QSFP 40G LR4 S Cisco 40GBASE SR BiDi duplex MMF LC QSFP 40G SR BD 100 GbE Tranceivers 100GBASE SR4 QSFP Transceiver MPO 100m over OM4 MMF QSFP 100G SR4 S 100GBASE LR4 QSFP Transceiver LC 10km over SMF QSFP 100G LR4 S 100GBASE CWDM4 QSFP Transceiver...

Страница 18: ...ctive direct attach optical cable 2 meter QSFP 100G AOC2M Cisco 100GBASE SFP28 active direct attach optical cable 3 meter QSFP 100G AOC3M Cisco 100GBASE SFP28 active direct attach optical cable 5 meter QSFP 100G AOC5M Cisco 100GBASE SFP28 active direct attach optical cable 7 meter QSFP 100G AOC7M Cisco 100GBASE SFP28 active direct attach optical cable 10 meter QSFP 100G AOC10M Cisco 100GBASE SFP28...

Страница 19: ...hannel LW SFP LC DS SFP FC32G LW The maximum length of fiber optic runs from the fabric interconnect to a chassis is limited to 300 meters This restriction is imposed by the use of 802 3X 802 1Qbb Priority Pauses Note Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 13 Product Overview SFP Fibre Channel Transceivers ...

Страница 20: ...Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 14 Product Overview SFP Fibre Channel Transceivers ...

Страница 21: ...y equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device Statement 1071 Warning SAVE THESE INSTRUCTIONS This unit is intended for installation in restricted access areas A...

Страница 22: ...e into consideration that hot air generated by equipment at the bottom of the rack can be drawn in the intake ports of the equipment above Ensure that exhaust airflow is unobstructed Fabric Interconnect Weight When lifting the system follow these guidelines Disconnect all power and external cables before lifting the system Have two people to lift the system The Cisco UCS 6454 weighs 25 9 pounds 11...

Страница 23: ...antial current draw fluctuations because of fluctuating data traffic patterns Ensure that circuits are sized according to local and national codes For North America the power supply requires a 15 A or 20 A circuit To prevent loss of input power ensure that the total maximum loads on the circuits supplying power to the fabric interconnect are within the current ratings for the wiring and breakers U...

Страница 24: ...ments for Cabinets and Racks The cabinet or rack must meet the following requirements Standard 19 in 48 3 cm four post EIA cabinet or rack with mounting rails that conform to English universal hole spacing per section 1 of ANSI EIA 310 D 1992 The minimum vertical rack space per Cisco UCS 6454 fabric interconnect must be one RU rack unit equal to 1 75 in 4 4 cm The width between the rack mounting r...

Страница 25: ...Requirements Specific to Standard Open Racks In addition to the requirements listed in the if mounting the chassis in an open rack no side panels or doors the minimum vertical rack space per chassis must be one RU rack unit equal to 1 75 in 4 4 cm The Cisco R Series racks meet or exceed all these requirements Cable Management Guidelines To help with cable management you might want to allow additio...

Страница 26: ...el and serial number of the damaged unit Description of damage Effect of damage on the installation Installing the Cisco UCS Chassis in a Cabinet or Rack This section describes how to use the rack mount kit provided to install a Cisco UCS Chassis into a cabinet or rack that meets the requirements described in Cabinet and Rack Requirements on page 18 If the rack is on wheels ensure that the brakes ...

Страница 27: ... bracket to four of the six screw holes on the side of the chassis The holes that you use depend on the requirements of your rack and the amount of clearance required for interface cables and power supply handles Note b Repeat Step 1 for the other front rack mount bracket on the other side of the chassis Figure 6 Attaching the Rack Mount Brackets to the Chassis Four M4 screws used to attach the br...

Страница 28: ...ews depending on the rack rail thread type For racks with square holes insert the 12 24 cage nuts in position behind the mounting holes in the slider rails a Repeat with the other slider rail on the other side of the rack b Use the tape measure and level to verify that the rails are horizontal and at the same height Figure 7 Installing the Slider Rails Step 4 Insert the chassis into the rack a Hol...

Страница 29: ... in each the two front rack mount brackets using a total of four screws and into the threaded holes in the vertical rack mounting rail b Repeat for the front rack mount bracket on the other side of the chassis Figure 9 Attaching the Chassis to the Rack Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 23 Installing the Cisco UCS Fabric Interconnect Installing the Cisco UCS Chassis in ...

Страница 30: ...he fabric interconnect because this device is equipped with AC input power supplies Proper Grounding Practices Grounding is one of the most important parts of equipment installation When you properly ground systems during installation you reduce or prevent shock hazards equipment damage due to transients and data corruption Table 7 Proper Grounding Guidelines Grounding Recommendations Electromagne...

Страница 31: ...dard office environment Electromagnetic noise problems are not anticipated but installing a grounding system is always recommended Best grounding recommendations should be followed as much as possible Low Existing commercial building is not subject to natural environmental noise or man made industrial noise This building contains a standard office environment In all situations grounding practices ...

Страница 32: ...correctly attach the ESD wrist strap In addition follow these guidelines when handling components Handle carriers by available handles or edges only avoid touching the printed circuit boards or connectors Place a removed component board side up on an antistatic surface or in a static shielding container If you plan to return the component to the factory immediately place it in a static shielding c...

Страница 33: ... if the rack is already grounded All power supplies must be grounded The receptacles of the AC power cables used to provide power to the fabric interconnect must be the grounding type and the grounding conductors should connect to protective earth ground at the service equipment When installing or replacing the unit the ground connection must always be made first and disconnected last Statement 10...

Страница 34: ...tial system configuration has been performed For instructions on configuring the system see the Configuration Guide for the version of Cisco UCS Manager that you are using The configuration guides are available at this URL http www cisco com c en us support servers unified computing ucs manager products installation and configuration guides list html Note When installing or replacing the unit the ...

Страница 35: ...to the console port of the primary or standalone fabric interconnect In a cluster configuration the primary will be the fabric interconnect that powers up first The console port on the terminal should be set to 9600 baud 8 data bits no parity 1 stop bit Step 6 If the fabric interconnect will be running in a cluster with another fabric interconnect you will need to connect Ethernet cables between t...

Страница 36: ...has booted and that the system has initialized without error messages If you cannot resolve an issue contact your customer service representative Step 12 Complete the worksheets provided in Site Preparation Checklist for future reference Step 13 Configure the primary fabric interconnect as described in thr Configuration Guide for the version of Cisco UCS Manager that you are using The configuratio...

Страница 37: ...nnect to a SAN When preparing your site for network connections to the Cisco UCS Fabric Interconnect consider the following for each type of interface and gather all the required equipment before connecting the ports Cabling required for each interface type Distance limitations for each signal type Additional interface equipment required You can save time and confusion when making cabling changes ...

Страница 38: ...ep 1 Plug the RJ 45 end of the serial management cable into the console port on the fabric interconnect and connect the DB 9 male end into the serial port on a laptop or other computer If the computer you will use does not have a serial port you will need to use the Serial to USB adapter Be sure to install the drivers for your adapter Step 2 Start your terminal software Step 3 Configure the termin...

Страница 39: ... cable to the Ethernet management connector port Use modular RJ 45 straight through UTP cables to connect the port to an Ethernet switch or hub Use a cross over cable to connect to a router interface Step 2 Connect the other end of the cable to the device Connecting to an SFP28 Ethernet or Fibre Channel Port Installing or Removing Cables into SFP Transceivers To prevent damage to the fiber optic c...

Страница 40: ...ansceiver Caution Procedure Step 1 Attach an ESD wrist strap and follow the instructions for its use Step 2 If a cable is installed in the transceiver a Record the cable and port connections for later reference b Press the release latch on the cable grasp the connector near the connection point and gently pull the connector from the transceiver c Insert a dust plug into the cable end of the transc...

Страница 41: ...sure that it is correctly positioned before continuing For instructions on verifying connectivity see the Configuration Guide for the version of Cisco UCS Manager that you are using The configuration guides are available at this URL http www cisco com c en us support servers unified computing ucs manager products installation and configuration guides list html Removing a Cable from a Transceiver T...

Страница 42: ... chassis Do not remove and insert a transceiver more often than is necessary Repeated removals and installation can shorten its useful life Keep all optical connections covered when not in use If they become dusty clean before using to prevent dust from scratching the fiber optic cable ends Do not touch ends of connectors ensuring that they remain free of fingerprints and other contamination Clean...

Страница 43: ...on Procedure Step 1 Use Cisco UCS Manager to perform the following tasks a Back up your Cisco UCS Manager configuration b Shut down the OS on all servers in the Cisco UCS domain c Disable the Smart Call Home feature in the Cisco UCS domain d Decommission every attached chassis in the Cisco UCS domain For details see the Configuration Guide for the version of Cisco UCS Manager that you are using Th...

Страница 44: ...single fabric interconnect with the same model of fabric interconnect Use Cisco UCS Manager either the GUI or the CLI to perform the software related tasks mentioned in the following procedure For additional information refer to the Cisco UCS Manager Getting Started Guide the Cisco UCS Manager Infrastructure Management Guide and the instructional videos available at this URL http www cisco com c e...

Страница 45: ...plugging it from the power source Example FI A show cluster extended state Cluster Id 0x537d0580bf9911e0 0x8955000decd07984 A UP PRIMARY B DOWN INAPPLICABLE A memb state UP lead state PRIMARY mgmt services state UP B memb state DOWN lead state INAPPLICABLE mgmt services state DOWN heartbeat state SECONDARY_FAILED INTERNAL NETWORK INTERFACES eth1 DOWN eth2 DOWN HA NOT READY Peer Fabric Interconnect...

Страница 46: ...ddress 122 255 252 1 Physical Switch Mgmt0 IPv4 address 122 255 252 3 Apply and save the configuration select no if you want to re enter yes no yes Applying configuration Please wait Configuration file Ok Cisco UCS 6454 Fabric Interconnect FI B login Step 13 If necessary upgrade the UCS Manager software If the replacement fabric interconnect is not running the same firmware version as the cluster ...

Страница 47: ...ress Peer Fabric interconnect Mgmt0 IPv4 Address xx xx xx xx Peer Fabric interconnect Mgmt0 IPv4 Netmask xx xx xx xx Cluster IPv4 address xx xx xx xx Peer FI is IPv4 Cluster enabled Please Provide Local Fabric Interconnect Mgmt0 IPv4 Address Physical Switch Mgmt0 IP address xx xx xx xx Apply and save the configuration select no if you want to re enter yes no yes Applying configuration Please wait ...

Страница 48: ...packing the Cisco UCS Fabric Interconnect for Return Shipment If you need to return the fabric interconnect remove the fabric interconnect from the rack and repack it for shipment If possible use the original packing materials and container to repack the unit Contact your Cisco customer service representative to arrange for return shipment to Cisco Cisco UCS 6454 Fabric Interconnect Hardware Insta...

Страница 49: ...2 to 104 F 0 to 40 C Temperature operating 40 to 158 F 40 to 70 C Temperature nonoperating 5 to 95 Humidity RH noncondensing 0 to 10000 ft 0 to 3000 m Altitude Power Specifications Cisco UCS Fabric Interconnect supports AC or DC power supplies You must use identical power supplies either two AC or two DC power supplies with the fabric interconnect In addition if you use a DC power supply you must ...

Страница 50: ... swappable Climate Savers Platinum Efficiency 80Plus Platinum Certified Efficiency rating Table 10 Specifications for the Cisco UCS 6332 DC Power Supply UCS PSU 6332 DC Cisco UCS 6332 Fabric Interconnect DC Power Supply Properties 930 W Maximum output per power supply 48 VDC Input voltage 23 A maximum 48 VDC Maximum HVDC input current 8 ms 50 load Maximum holdup time 12 VDC Power supply output vol...

Страница 51: ...nd which damage to the device may occur if these limits are exceeded for other than a short period of time 2 Functional performance is not intended device reliability is not implied and damage to the device may occur over an extended period of time between absolute maximum ratings and the recommended operating conditions General Specifications for Cisco Fibre Channel SFP Transceivers The table bel...

Страница 52: ...mit power 3 Approximate actual distance may vary depending on fiber quality and other factors Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 46 Technical Specifications General Specifications for Cisco Fibre Channel SFP Transceivers ...

Страница 53: ...ails 2 rack mount guides 2 rack mount brackets 12 M4 x 0 7 x 8 mm Phillips countersunk screws 10 10 32 rack nuts 10 10 32 x 3 4 inch Phillips pan head screws 1 console cable with an RJ 45 RS 232 adapter and a DB9 adapter 1 ground lug kit 1 ESD wrist strap 1 power cord clip a wire clip that is used to retain the power cord 1 pointer document specifies where to find the online product documentation ...

Страница 54: ...1 P1 45 Pins Signal Name CTS 8 1 RTS DSR 6 2 DTR ZXD 2 3 TXD GND 5 4 GND GND 5 5 GND TXD 3 6 ZXD DTR 4 7 DSR RTS 7 8 CTS Console Port The console port is an asynchronous RS 232 serial port with an RJ 45 connector The table below lists the pinouts for the console port on the Cisco UCS 6454 Fabric Interconnect Table 15 Console Port Pinouts Signal Pin RTS 1 Cisco UCS 6454 Fabric Interconnect Hardware...

Страница 55: ...tacles The jumper power cords for use in cabinets are available as an optional alternative to the standard power cords The standard power cords have an IEC C13 connector on the end that plugs into the power supplies The optional jumper power cords have an IEC C13 connector on the end that plugs into the power supplies and an IEC C14 connector on the end that plugs into an IEC C13 outlet receptacle...

Страница 56: ...VAC 10 A 3112 Length 8 2 feet 2 5 meters Figure 12 CAB 9K10A AU Plug EL 206 A S 3112 2000 Cordset rating 10 A 250 V 500V Length 2500mm 186581 Connector EL 701C IEC 60320 C15 Peoples Republic of China Power Cord SFS 250V 10A CN Plug 250 VAC 10 A GB 2009 Length 8 2 feet 2 5 meters Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 50 Cable and Port Specifications Australia and New Zealan...

Страница 57: ...M 2511 Length 8 2 feet 2 5 meters Figure 14 CAB 9K10A EU Connector VSCC15 Cordset rating 10A 16 A 250 V Length 8 ft 2 in 2 5 m Plug M2511 186576 India South Africa and United Arab Emirates Power Cord SFS 250V 10A ID Plug 250 VAC 16A EL 208 Length 8 2 feet 2 5 meters Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 51 Cable and Port Specifications Europe ...

Страница 58: ... Length 8 2 feet 2 5 meters Figure 16 SFS 250V 10A IS Cordset rating 10A 250V 500V MAX 2500 mm Plug EL 212 SI 32 186574 Connector EL 701B IEC60320 C13 EL 212 16A 250V Italy Power Cord CAB 9K10A IT Plug 250 VAC 10 A CEI 23 16 Length 8 2 feet 2 5 meters Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 52 Cable and Port Specifications Israel ...

Страница 59: ... America CAB AC 250V 13A Power Cord CAB AC 250V 13A Plug 250 VAC 13 A IEC60320 Length 6 6 feet 2 0 meters Figure 18 CAB AC 250V 13A CAB N5K6A NA Power Cord CAB N5K6A NA Plug 250 VAC 13 A NEMA 6 15 Length 8 2 feet 2 5 meters Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 53 Cable and Port Specifications North America ...

Страница 60: ...gure 20 CAB 9K10A SW Cordset rating 10 A 250 V Length 8 2 ft 186570 Plug NEMA 6 15P Connector IEC60320 C13 Taiwan Power Cord CAB ACTW Plug 125 VAC 10 A CNS10917 Length 7 5 feet 2 3 meters Figure 21 CAB ACTW Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 54 Cable and Port Specifications Switzerland ...

Страница 61: ...1C EN 60320 C15 EL 210 BS 1363A 13 AMP fuse Cabinet Jumper Power Cords Jumper Power Cord CAB C13 C14 JMPR Plug 250 VAC 10 A C13 C14 Connectors Length 2 2 feet 0 7 meters Figure 23 CAB C13 C14 JMPR Jumper Power Cord CAB C13 C14 AC Plug 250 VAC 10 A C13 C14 Connectors Length 9 8 feet 3 meters Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 55 Cable and Port Specifications United Kingd...

Страница 62: ...ower Cord CAB C13 C14 2M Plug 250 VAC 10 A C13 C14 Connectors Length 6 6 feet 2 meters Figure 25 CAB C13 C14 2M Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 56 Cable and Port Specifications Cabinet Jumper Power Cords ...

Страница 63: ...t of your equipment is essential for successful system operation ventilation and accessibility Consider heat dissipation when sizing the air conditioning requirements for an installation Table 16 Site Planning Checklist Date Time Verified By Planning Activity Task No Space evaluation Space and layout Floor covering Impact and vibration Lighting Maintenance access 1 Cisco UCS 6454 Fabric Interconne...

Страница 64: ...ype Power receptacles Receptacle proximity to the equipment Dedicated circuit for power supply Dedicated separate circuits for redundant power supplies UPS for power failures 3 Grounding evaluation Circuit breaker size CO ground AC powered systems 4 Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 58 Site Planning and Maintenance Records Site Preparation Checklist ...

Страница 65: ...ted AC source circuit 5 UPS uninterruptible power supply 6 EMI electromagnetic interference 7 RFI radio frequency interference Contact and Site Information Use the following worksheet to record contact and site information Table 17 Contact and Site Information Contact person Contact phone Contact e mail Building site name Data center location Floor location Address line 1 Address line 2 Cisco UCS ...

Страница 66: ...___ Product Number________________________________________________ Table 18 Network Related Information System IP address System IP netmask Hostname Domain name IP broadcast address Gateway router address DNS address Modem telephone number Table 19 Module Information Notes Module Serial Number Module Type Slot Fixed 1 Expansion 2 Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 60 Si...

Страница 67: ...B Connection Notes Port Channel Group LAN or SAN Pin Group Port FEX Chassis Port Slot 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 61 Site Planning and Maintenance Records Chassis and Module Information ...

Страница 68: ... Channel Group LAN or SAN Pin Group Port FEX Chassis Port Slot 26 27 28 29 30 31 32 1 2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Cisco UCS 6454 Fabric Interconnect Hardware Installation Guide 62 Site Planning and Maintenance Records Chassis and Module Information ...

Отзывы: