Type exit to disconnect from nxos
Display of inventory will also show install of FC Modules into the switches
! exit from "nxos" mode to switch mode,
and making sure you are seeing the FC module
cae−sj−ca−B# show fabric−interconnect inventory expand
Switch A:
Switch Card:
Slot Description Num Ports State PID Serial (SN)
−−−−− −−−−−−−−−−−−−−−−−−−− −−−−−−−−−− −−−−−−−−−− −−−−−−−−−−−−−−− −−−−−−−−−−−
1 20x10GE/Supervisor 20 Online N10−S6100 JAF1242ASGK
2 8x1/2/4G FC Module 8 Online N10−E0080 JAB123800NM
2. Identify Fiber Channel components and Connectivity in Cisco UCS
Before you configure the fabric interconnect to support VSAN, you need to make sure that your FC uplink
expansion works and is visible from the fabric interconnect. Complete these steps:
Log into UCS Manager GUI mode.
1.
In the Navigation pane, choose Equipment.
2.
Choose Fabric Interconnect > Fabric Interconnect #.
3.
Choose Uplink FC Ports.
4.