Cisco SFS 3001 Multifabric Server Switch 

Quick Start Guide

 (Topspin 90 Quick Start Guide

)

Release 2.1.0

Part Number: 

OL

-

7712

-0

1

Product ID: 140252

Содержание TOPSPIN SFS 3001

Страница 1: ...Cisco SFS 3001 Multifabric Server Switch Quick Start Guide Topspin 90 Quick Start Guide Release 2 1 0 Part Number OL 7712 01 Product ID 140252 ...

Страница 2: ...tion thereof by or for the U S Government shall be governed solely by the terms of the license agreement and shall be prohibited except to the extent expressly permitted by the terms of that agreement Any technical data provided that is not covered by the above provisions shall be deemed technical data commercial items pursuant to DFAR section 227 7015 a or equivalent Any use modification reproduc...

Страница 3: ...quirements 2 Prepare for the Installation 2 Rack Mount Installation 2 Install Expansion Modules Optional 5 Cable the Switch 5 Connect Management Ports 5 Connect InfiniBand Cables 6 Optional Connect to Ethernet Devices 6 Optional Connect to Fibre Channel Devices 6 Connect the Power Cable 6 Configure Basic Connectivity 6 Assigning an Address Statically 6 Assigning an Address Dynamically DHCP 7 Conne...

Страница 4: ...iv Launch Chassis Manager 11 Configure Additional Settings 12 Optional Configure the Ethernet Gateway 13 Layer 2 Bridging Procedure 13 Configure the Fibre Channel Gateway Optional 15 ...

Страница 5: ...se harmful interference in which case the user will be required to correct the interference at his own expense Safety Information Electrical Cautions on page v General Cautions on page vii Laser Cautions on page vii Electrical Cautions Use only the power cable provided with your Topspin system Inspect the power cord and determine if it provides the proper plug and is appropriately certified for us...

Страница 6: ...rmly in place CAUTION The Topspin system contains lithium batteries Do not attempt to replace or discard these batteries The batteries may only be serviced by Topspin service personnel CAUTION Observe and follow service markings Do not service the Topspin system except as explained in the Topspin documentation supplied with your system Opening the chassis or removing the enclosure cover exposes yo...

Страница 7: ...s In general Do not spill food or liquids on your system components Protect your Topspin system from sudden power surges and interruptions by using a surge suppressor line conditioner or uninterruptable power supply UPS Place cables appropriately so that they do not obstruct any egress within the data center and they do not block any ventilation inlets or outlets Rack mount the Topspin chassis acc...

Страница 8: ...O connector Standards used CDRH 21CFR Chapter I 1040 10 IEC IEC60825 1 1994 Table III 2 Customer Contact Information Address Topspin Communications Inc 515 Ellis St Mountain View CA 94043 Telephone Corporate Headquarters 866 TOPSPIN or 650 316 3300 Fax 650 316 3269 Telephone Technical Support 800 499 1473 Email Technical Support support topspin com Web site Support http support topspin com ...

Страница 9: ... on page 6 Connect and Configure InfiniBand Hosts on page 8 Install the Element Manager GUI on page 10 Launch Chassis Manager on page 11 Configure Additional Settings on page 12 Optional Configure the Ethernet Gateway on page 13 Configure the Fibre Channel Gateway Optional on page 15 Prepare the Site 1 Read the cautionary statements in Safety Information on page v 2 Unpack the Topspin 90 package u...

Страница 10: ...ure the brackets to your rack 2 for each rail of the rack Two people are recommended to perform the install Prepare for the Installation 1 Open the shipping package if you have not already done so Remove the chassis rack brackets CD ROM parts bag and documentation 2 Place the chassis on a secure clean surface 3 Open the plastic bag containing mounting parts 4 Check the slot in the rack for suffici...

Страница 11: ...e the flange toward the front of the chassis However you can also mount the flange toward the back if you want to mount the switch backward in the chassis service side forward Figure 1 2 Attaching One Rail to Server Switch Chassis 3 Repeat step 1 and step 2 for the other side of the switch chassis NOTE The two counterparts to these sliding rails without screw holes should still be unattached 4 Che...

Страница 12: ...e rack bracket should be installed toward the front of the rack b Secure the brackets with your screws through the back of the rack posts as shown in Figure 1 4 c Repeat on both sides of the rack Figure 1 3 Holding Rack Bracket Against Inside of Rack Figure 1 4 Secure Rack Brackets to Rack with Screws 6 Lift the switch unit and align the bracket on the switch with the bracket on the rack before sl...

Страница 13: ... 1 Install any optional Fibre Channel or Ethernet Gateway modules 2 Install all hardware components before the Topspin 90 is powered on 3 A gateway module or blanking panel must always be installed Cable the Switch Connect Management Ports 1 Connect one end of the RJ 45 console cable to the InfiniBand chassis serial console port 2 Connect the other end of the serial cable to your terminal server o...

Страница 14: ...g the other end of each AC power cable into an outlet operating at 90 132 VAC or 180 264V AC auto ranging 47 63Hz 3 Check the System LED on the chassis to see if it is green It will be blinking yellow green until the power on test is complete Configure Basic Connectivity 1 Configure an IP address for the Ethernet Management port It is necessary to configure connectivity to the out of box Ethernet ...

Страница 15: ... Enter the user name and password The default user name is super and the default password is super c Enter the enable command d Enter the configure command e Enter the interface mgmt ethernet command Topspin 90 enable Topspin 90 Topspin 90 configure Topspin 90 config Topspin 90 config interface mgmt ethernet Topspin 90 config if mgmt ethernet ip address 10 10 0 22 255 255 255 0 Topspin 90 config i...

Страница 16: ...X slot For more information see the Host Channel Adapter Installation Guide 2 Power on the host system 3 Install the HCA driver s An integrated suite of drivers is provided including IPoIB SRP SDP uDAPL and MPI a Make sure your Linux kernel is supported Refer to the Topspin Web site for a list of supported versions b Insert the supplied CD ROM into the CD ROM drive The CD ROM is provided in the pa...

Страница 17: ... the HCA uses port 1 of the first HCA MPI requires the use of HCA 1 port 1 Setup rsh or ssh on two nodes so that you can run commands between a remote and local node without entering a login or password This is required to use the MPI protocol Add paths to your environment PATH usr local topspin mpi mpich bin usr local topspin bin or Add the paths for all users by adding the following line to your...

Страница 18: ...heck that your IB cable connector engages fully Wiggle your connector back and forth to be sure that both sides of the connector have locked firmly into place b To remove a cable with a pinch connector pinch both sides of the back of the connector and pull the connector away from the port Figure 1 8 Removing a Pinch Connector Install the Element Manager GUI 1 Check that you have sufficient system ...

Страница 19: ...change to the installation directory and run the Element Manager with TopspinEM b On Windows platforms click Programs Topspin Element Manager TopspinEM c When prompted to enter a device name enter the DNS host name or IP address of the Topspin 90 and community string for the unrestricted user The default community string for the unrestricted user is secret Launch Chassis Manager To launch Chassis ...

Страница 20: ...me settings The Topspin 90 has internal clocks that are set at the factory You can also configure this manually or via NTP servers If you do not want to configure the clock at this time skip this step In the Element Manager GUI go to Maintenance Time Enter your settings Login super Password xxxxx Topspin 90 enable Topspin 90 show version System Version Information system version Topspin 90 Topspin...

Страница 21: ...ocedure describes the first topology bridging one subnet this topology includes the following main steps creating a bridge group for a non tagged Ethernet port creating a bridge group that uses the default pkey For information regarding configuring bridge ports for tagged Ethernet ports or for configuring more complex topologies refer to the Ethernet Gateway User Guide Layer 2 Bridging Procedure R...

Страница 22: ...Return to User Exec mode and view the bridge group Enter exit Enter exit Enter show bridge group Example All configured bridging ports are displayed 7 Configure the Ethernet hosts by entering ifconfig eth ip address netmask netmask Log in to the host as a root user Enter ifconfig eth subnet netmask Example Repeat for all Ethernet hosts Topspin 90 config bridge group 21 broadcast forwarding Topspin...

Страница 23: ... your gateway s discovered Example 6 Enter the fc srp initiator command with the GUID of the host from step 3 the GUID extension always 00 00 00 00 00 00 00 00 the auto bind keyword to configure your host NOTE For an initiator to successfully connect to storage each physical FC gateway port requires a virtual port with a unique WWPN that points to the initiator Also the initiator requires a unique...

Страница 24: ...ysical FC gateway port and assigns a WWPN to each virtual port Example 7 Optional Enter the fc srp initiator command with the GUID of the host the GUID extension the description keyword to assign an easily recognizable identifier to the initiator Example Topspin 90 configure terminal Topspin 90 config fc srp initiator 00 05 ad 00 00 01 29 5c 00 00 00 00 00 00 00 00 auto bind Topspin 90 config fc s...

Страница 25: ...34 40 00 00 00 00 4 1 20 01 00 05 ad 40 40 00 00 00 00 4 2 20 01 00 05 ad 44 40 00 00 00 00 5 1 20 01 00 05 ad 50 40 00 00 00 00 5 2 20 01 00 05 ad 54 40 00 00 00 00 6 1 20 01 00 05 ad 60 40 00 00 00 02 6 2 20 01 00 05 ad 64 40 00 00 00 00 7 1 20 01 00 05 ad 70 40 00 00 00 00 7 2 20 01 00 05 ad 74 40 00 00 00 00 8 1 20 01 00 05 ad 80 40 00 00 00 00 8 2 20 01 00 05 ad 84 40 00 00 00 00 9 1 20 01 00...

Страница 26: ...p lunid 00 00 00 00 00 00 00 00 logical id raw 64 bytes 01 03 00 08 20 00 00 04 cf f6 c2 ab 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 logical id formatted display 2000000000000000 description itl device category random lun policy restricted non restricted ports none active ports none p...

Страница 27: ...u want to unmask to grant the initiator portmask policy access to the target Example 13 Enter the no fc srp itl command with the GUID of the host the GUID extension of the host the WWPN of the target the LUN ID of the storage disk the gateway portmask policy keyword the restricted keyword the all keyword or the ports you want to unmask to grant the initiator portmask policy access to the LUN Examp...

Страница 28: ...to User Exec mode or Privileged Exec mode and enter the show fc srp itl command to verify that the ITL is active Port numbers appear in the physical access and active ports fields to indicate that the ITL is active ...

Страница 29: ...eway configuring 13 Ethernet gateway configuring 13 expansion modules installing 5 F Fibre Channel gateway configuring 15 G gateways installing 5 H hosts connecting and configuring 8 I InfiniBand cables connecting 6 installing Element Manager 10 installing in a rack 2 IP address 6 L launching Chassis Manager 11 M mounting 2 P preparing 1 R rack mounting 2 racking 2 S ssh 12 starting Chassis Manage...

Страница 30: ......