Precautions
Please follow the steps in this installation guide when
unpacking and assembling Profile 55” Dual.
unPacking the system at the destination
It is highly recommend to start the unpacking and assembling
of Profile 55” Dual at the place where it is to be used.
note:
If it is not possible to bring the complete delivery to
the room where Profile 55” Dual is to be used, then unpack
and bring the smaller units to the destination.
•
The monitor box requires two (2) persons to lift (55 kg /
121 lb).
•
The bottom module column requires two (2) persons to lift
(40 kg / 88 lb).
•
The foot module requires two (2) persons to lift
(stand-alone: 35 kg / 77 lb; wall mount: 20 kg / 44 lb).
manPower
A minimum of two (2) persons are required when installing
Profile 55” Dual.
installation near a socket-outlet
The equipment must be installed near a socket-outlet. The
socket-outlet shall be easily accessible after installation.
room guidelines
note:
The floor must be in level.
The recommended distance between the Profile 55” Dual
and the meeting room table should be minimum 1.5 m / 59 in.
Read more about room guidelines in the Video conferencing
room primer.
user documentation
The user documentation for this product, including
compliance and safety information, is available on the Cisco
web site.
Go to:
http://www.cisco.com/go/telepresence/docs
.
dimensions of the Profile 55” dual
•
Height: 64.6” / 164 cm
•
Width: 99.2” / 252 cm
•
Depth (wall mount): 10.2” / 26 cm
•
Depth (stand-alone): 17.7” / 45 cm
•
Weight: 440 lb / 200 kg
leVelling adJustment
Make sure the unit is stable.
Place the level adjustment tool on the
foot wheel under the foot module for
height adjustment.
Seen from above, turn clockwise to
adjust the height up. Use the opposite
side of the tool and turn counterclockwise
to adjust down.
Installing Cisco TelePresence System Profile 55” Dual
Page 1
78-20440-01 Profile 55 Dual Installation Sheet | 2011 OCTOBER | © 2011 Cisco Systems, Inc. All rights reserved.
the Profile 55” dual deliVery contains:
Monitor box:
•
Two monitors and
speaker grilles
Bottom module column
Camera
Touch 8” interface device
Foot module box:
•
Foot module (stand-alone or wall
mount)
•
Six M8×45 screws
•
Two wall mount brackets and four
M6×10 screws (for wall mount only)
•
Level adjustment tool
Monitor back cover box:
•
Monitor back cover
•
Two M4
×
15 screws for the back
cover
•
Monitor brackets
•
M4
×
25 and M4
×
8 screws for the
monitor brackets
•
Four M8
×
15 screws to fasten the
monitors to the column
Accessories box:
•
Cables
•
Microphones, 4 pcs
•
Remote control and 4 AAA
batteries
•
Gloves, 2 pairs
•
Cleaning cloth
•
Allen key, screwdriver
1
content overview
Remove the outer cover and locate the different boxes as illustrated below.
2
lifting the column out of the package. mounting the column to the foot module to complete the bottom module
Left monitor
Right monitor
Column
Stand-alone
foot module
3
when you haVe a wall mount foot module:
mounting the column to the foot module and fastening it to the wall
caution
Due to the size and weight of this equipment, it is very
important that the wall mount unit is safely installed
according to the installation instructions and that the
wall is able to safely support the product. It is highly
recommended that the wall mounted system is installed
by trained personnel.
Mount the column to the wall mount foot module, similar to step 2.
1.
Fasten the wall brackets to the bottom module with the four M6
×
10
screws. Use the Allen key.
2.
Place the bottom module by the wall, mark where to fasten the
bracket and move the bottom module away.
3.
Add the suitable fixing device for the screws in the wall, and fasten
the bottom module.
1.
Move the foot module to its
permanent location, and place the
column on the foot module.
2.
Open the rear door. Unscrew the two
thumb nuts and remove the door stop
bracket.
3.
Carefully open the rear door
completely.
4.
Fasten the column to the foot module
with three M8
×
45 screws on each
side as illustrated to the right.
5.
Fasten the door stop bracket again
with the two thumb nuts.
caution
heaVy
Rev. Date
Prep.
Checked Change
-
-
-
Telecom AS
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Part weight:
Sheet size:
Scale:
Surface treatment
Specification:
Material
Tolerances
Unit:
European
projection
Sheet 1 of 1
All materials, finishes, and proccesses
must comply with the RoHS directives
Dimensions without paint or finish
Flame class requirement: -
Processes
Type:
Manufacturer:
Type number:
Thickness:
Color:
Surface:
Glossiness:
Flame class:
UL reference:
3D CAD model file 120601 rev. 03 is master
Packaging Kit Profile 52" Dual
120601 rev.
71743g
A3
mm
1:8
Monitor back cover and monitor brackets
Right and left monitor
Bottom module column
Camera
Foot module
Accessories box
Touch controller
Add the suitable fixing device for the screws in the wall.
The wall
caution
heaVy
The monitors come in a separate box. The monitor box contains monitors and
speaker grilles for the monitors. Remove the lid and locate the left and right
monitors and the speaker grilles.
caution
heaVy
Front
Rev. Date
Prep.
Checked Change
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Part weight:
Sheet size:
Scale:
Surface treatment
Specification:
Material
Tolerances
Unit:
European
projection
Sheet 1 of 1
All materials, finishes, and proccesses
must comply with the RoHS directives
Dimensions without paint or finish
Flame class requirement: -
Processes
Type:
Manufacturer:
Type number:
Thickness:
Color:
Surface:
Glossiness:
Flame class:
UL reference:
3D CAD model file 117325 rev. 00D is master
TANDBERG Aquarius dual 52"
117325 rev.
38276168g
A3
mm
1:7
-
-
-
-
-
-
-
-
-
-
Grab here when
lifting the column.
caution
heaVy
Front
Rear side
Door stop bracket
Rear side
Screws to
fasten the
column
Screws to
fasten the
column
Access the innermost screws through these holes.
The bottom module is viewed from the rear side.
Allen key and
six M8
×
45
screws
Allen key and four
M6
×
10 screws
Screws to fasten the wall