background image

Precautions

Please follow the steps in this installation guide when 

unpacking and assembling Profile 55” Dual.

unPacking the system at the destination

It is highly recommend to start the unpacking and assembling 

of Profile 55” Dual at the place where it is to be used. 

note:

 

If it is not possible to bring the complete delivery to 

the room where Profile 55” Dual is to be used, then unpack 

and bring the smaller units to the destination. 

• 

The monitor box requires two (2) persons to lift (55 kg / 

121 lb).

• 

The bottom module column requires two (2) persons to lift  

(40 kg  /  88 lb).

• 

The foot module requires two (2) persons to lift 

(stand-alone: 35 kg / 77 lb; wall mount: 20 kg / 44 lb).

manPower

A minimum of two (2) persons are required when installing 

Profile 55” Dual.

installation near a socket-outlet

The equipment must be installed near a socket-outlet. The 

socket-outlet shall be easily accessible after installation.

room guidelines

note:

 

The floor must be in level.

The recommended distance between the Profile 55” Dual 

and the meeting room table should be minimum 1.5 m / 59 in. 
Read more about room guidelines in the Video conferencing 

room primer.

user documentation

The user documentation for this product, including 

compliance and safety information, is available on the Cisco 

web site. 
Go to: 

http://www.cisco.com/go/telepresence/docs

.

dimensions of the Profile 55” dual

• 

Height: 64.6” / 164 cm

• 

Width: 99.2” / 252 cm

• 

Depth (wall mount): 10.2” / 26 cm

• 

Depth (stand-alone): 17.7” / 45 cm

• 

Weight: 440 lb / 200 kg

leVelling adJustment 

Make sure the unit is stable. 
Place the level adjustment tool on the 

foot wheel under the foot module for 

height adjustment. 
Seen from above, turn clockwise to 

adjust the height up. Use the opposite 

side of the tool and turn counterclockwise 

to adjust down.

Installing Cisco TelePresence System Profile 55” Dual

Page 1

78-20440-01 Profile 55 Dual Installation Sheet | 2011 OCTOBER | © 2011 Cisco Systems, Inc. All rights reserved.

the Profile 55” dual deliVery contains:

Monitor box:

• 

Two monitors and  

speaker grilles

Bottom module column
Camera
Touch 8” interface device 
Foot module box:

• 

Foot module (stand-alone or wall 

mount)

• 

Six M8×45 screws 

• 

Two wall mount brackets and four 

M6×10 screws (for wall mount only)

• 

Level adjustment tool

Monitor back cover box:

• 

Monitor back cover

• 

Two M4

×

15 screws for the back 

cover

• 

Monitor brackets

• 

M4

×

25 and M4

×

8 screws for the  

monitor brackets

• 

Four M8

×

15 screws to fasten the 

monitors to the column

Accessories box:

• 

Cables

• 

Microphones, 4 pcs

• 

Remote control and 4 AAA 

batteries

• 

Gloves, 2 pairs

• 

Cleaning cloth

• 

Allen key, screwdriver

content overview

Remove the outer cover and locate the different boxes as illustrated below.

lifting the column out of the package. mounting the column to the foot module to complete the bottom module

Left monitor
Right monitor

Column

Stand-alone  

foot module

when you haVe a wall mount foot module:  

mounting the column to the foot module and fastening it to the wall

caution

Due to the size and weight of this equipment, it is very 

important that the wall mount unit is safely installed 

according to the installation instructions and that the 

wall is able to safely support the product. It is highly 

recommended that the wall mounted system is installed 

by trained personnel.

Mount the column to the wall mount foot module, similar to step 2.

1. 

Fasten the wall brackets to the bottom module with the four M6

×

10 

screws. Use the Allen key.

2. 

Place the bottom module by the wall, mark where to fasten the 

bracket and move the bottom module away.

3. 

Add the suitable fixing device for the screws in the wall, and fasten 

the bottom module.

1. 

Move the foot module to its 

permanent location, and place the 

column on the foot module.

2. 

Open the rear door. Unscrew the two 

thumb nuts and remove the door stop 

bracket.

3. 

Carefully open the rear door 

completely.

4. 

Fasten the column to the foot module 

with three M8

×

45 screws on each 

side as illustrated to the right.

5. 

Fasten the door stop bracket again 

with the two thumb nuts.

caution

heaVy

Rev. Date

Prep.

Checked Change

-
-
-

Telecom AS

-
-
-
-
-
-
-
-
-

-
-
-
-
-
-
-
-
-

Part weight:

Sheet size:

Scale:

Surface treatment

Specification:

Material

Tolerances

Unit:

European
projection

Sheet 1 of 1

All materials, finishes, and proccesses
must comply with the RoHS directives 

Dimensions without paint or finish

Flame class requirement:   -

Processes

Type:
Manufacturer:
Type number:
Thickness:
Color:
Surface:
Glossiness:
Flame class:
UL reference:

3D CAD model file 120601 rev. 03 is master

Packaging Kit Profile 52" Dual

120601 rev.

71743g

A3

mm

1:8

Monitor back cover and monitor brackets

Right and left monitor

Bottom module column

Camera

Foot module

Accessories box

Touch controller

Add the suitable fixing device for the screws in the wall.

The wall

caution

heaVy

The monitors come in a separate box. The monitor box contains monitors and 

speaker grilles for the monitors. Remove the lid and locate the left and right 

monitors and the speaker grilles.

caution

heaVy

Front

Rev. Date

Prep.

Checked Change

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Part weight:

Sheet size:
Scale:

Surface treatment

Specification:

Material

Tolerances

Unit:

European

projection

Sheet 1 of 1

All materials, finishes, and proccesses

must comply with the RoHS directives 

Dimensions without paint or finish

Flame class requirement:   -

Processes

Type:

Manufacturer:

Type number:

Thickness:

Color:

Surface:

Glossiness:

Flame class:

UL reference:

3D CAD model file 117325 rev. 00D is master

TANDBERG Aquarius dual 52"

117325 rev.

38276168g

A3

mm

1:7

-

-

-

-

-

-

-

-

-

-

Grab here when 

lifting the column. 

caution

heaVy

Front

Rear side

Door stop bracket

Rear side

Screws to 

fasten the 

column

Screws to 

fasten the 

column

Access the innermost screws through these holes.

The bottom module is viewed from the rear side.

Allen key and 

six M8

×

45 

screws

Allen key and four 

M6

×

10 screws

Screws to fasten the wall 

bracket to the bottom module

Отзывы: