INSTALLATION

Installing the Defense Center

The Sourcefire 3D System is delivered on different hardware platforms that you can 

rack-mount. When you install a Defense Center, make sure that you can access the 
Defense Center’s console for initial setup.

You can access the console for the first configuration of a new Defense Center using a 
keyboard and monitor with KVM, or using an Ethernet connection to the management 

interface.

Keyboard and Monitor/KVM

You can connect a USB keyboard and VGA monitor to any Sourcefire Defense Center, 
which is useful for rack-mounted Defense Centers connected to a keyboard, video, and 
mouse (KVM) switch.

IMPORTANT!  Do not use a KVM switch with USB mass storage to access the Defense 

Center because the Defense Center may attempt to use the mass storage device as a 
boot device.

Ethernet Connection to Management Interface

Configure a local computer, which must not be connected to the internet, with the 
following network settings:

IP address: 

• 

192.168.45.2

netmask: 

• 

255.255.255.0

default gateway: 

• 

192.168.45.1

Using an Ethernet cable, connect the network interface on the local computer to the 
management interface on the Defense Center. To interact with the Defense Center, use 
terminal emulation software such as HyperTerminal or XModem. The settings for this 
software are as follows: 

9600 baud

• 

8 data bits

• 

no parity checking

• 

1 stop bit

• 

no flow control

• 

Note that the management interface on a physical Sourcefire Defense Center 
is preconfigured with a default IPv4 address. However, you can reconfigure the 
management interface with an IPv6 address as part of the setup process.

Quick Start Guide - DC750

DC750

2014-5.3-2

Содержание Sourcefire Defense Center 750

Страница 1: ...hout proper instruction Required items flathead and Phillips screwdrivers for the rack mounting kit laptop or monitor and keyboard to connect directly to the Defense Center Thank you for choosing Sourcefire Before installing this Defense Center download and follow the instructions in the Sourcefire Support Welcome Kit https support sourcefire com to get started with Sourcefire Support and to set u...

Страница 2: ...enter because the Defense Center may attempt to use the mass storage device as a boot device Ethernet Connection to Management Interface Configure a local computer which must not be connected to the internet with the following network settings IP address 192 168 45 2 netmask 255 255 255 0 default gateway 192 168 45 1 Using an Ethernet cable connect the network interface on the local computer to th...

Страница 3: ... and plug them into separate power sources Turn on the Defense Center 4 If you are using a keyboard and monitor to set up the Defense Center continue with Configuring Network Setting Using a Script in the Sourcefire 3D System Installation Guide If you are using a direct Ethernet connection to set up the Defense Center confirm that the link LED is on for both the network interface on the local comp...

Страница 4: ...olts 50 60 Hz OperatingTemperature 50 F to 95 F 10 C to 35 C with the maximum rate of change not to exceed 18 F 10 C 50 F to 95 F 10 C to 35 C with the maximum rate of change not to exceed 18 F 10 C Non OperatingTemperature 40 F to 158 F 40 C to 70 C 40 F to 158 F 40 C to 70 C Non Operating Humidity 90 non condensing at 95 F 35 C 90 non condensing at 82 4 F 28 C Acoustic Noise 7 0 dBA rack mount i...

Отзывы: