5-7
Cisco SFS 7000P Hardware Installation Guide
OL-9167-01 Rev. A0
Chapter 5 Hardware Diagnostic Tests
Running Power Supply Tests
card(17) none
fan(1) none
fan(2) none
Step 5
Reboot the chassis when the self-test is complete.
SFS-7000P#
reload
System configuration is modified. Save? [yes(default) | no | filename]
y
Proceed with reload? [yes(default) | no]
y
Running Power Supply Tests
The following tests are available to locate and diagnose fan modules:
•
LED
•
Self-Test
Running a LED Test on the Power Supply
You can use the LED test to identify a specific power supply by entering these
commands:
SFS-7000P>
enable
SFS-7000P#
config
SFS-7000P(config)#
diag power-supply 1
SFS-7000P(config-diag-power-supply-1)#
test led
SFS-7000P(config-diag-power-supply-1)#
start
SFS-7000P(config-diag-power-supply-1)#
stop
SFS-7000P(config-diag-power-supply-1)#
Running a Self-Test on a Power Supply
To perform a diagnostic self-test on a power supply, follow these steps:
Step 1
Determine the ID of the power supply that you want to diagnose, if you do not
already know the number.