background image

Power Supply Installation

This chapter applies only to the Catalyst 6800IA-48FPDR switch. It contains these topics:

Power Supply Module Overview, page 1

Installation Guidelines, page 3

Installing or Replacing an AC Power Supply, page 4

Finding the Serial Number, page 5

Power Supply Module Overview

The switch operates with either one or two active power supply modules. You can use two AC modules, or
one module and a blank cover.

Table 1: Power Supply Model Numbers and Description

Description

Part Number

1025-W AC power supply module

PWR-C2-1025WAC=

The 1025-W power supply module is an autoranging unit that supports input voltages between 115 and 240
VAC. All power supply modules have internal fans. All switches ship with a blank cover in the second power
supply slot.

Catalyst 6800IA Switch Hardware Installation Guide    

    OL-30278-02

1

Содержание PWR-C2-1025WAC

Страница 1: ...with either one or two active power supply modules You can use two AC modules or one module and a blank cover Table 1 Power Supply Model Numbers and Description Description Part Number 1025 W AC power supply module PWR C2 1025WAC The 1025 W power supply module is an autoranging unit that supports input voltages between 115 and 240 VAC All power supply modules have internal fans All switches ship w...

Страница 2: ... connector 4 AC OK LED 1 Release latch 5 PS OK LED 2 Power supply 6 AC power cord retainer 3 If no power supply is installed in a power supply slot install a power supply slot cover Figure 2 Power Supply Slot Cover Catalyst 6800IA Switch Hardware Installation Guide 2 OL 30278 02 Power Supply Installation Power Supply Module Overview ...

Страница 3: ...switch with one power supply module slot empty For proper chassis cooling both module slots must be populated with either a power supply or a blank module Caution Blank faceplates and cover panels serve three important functions they prevent exposure to hazardous voltages and currents inside the chassis they contain electromagnetic interference EMI that might disrupt other equipment and they direc...

Страница 4: ... inward and slide the power supply out Do not leave the power supply slot open for more than 90 seconds while the switch is operating Note This unit might have more than one power supply connection All connections must be removed to de energize the unit Statement 1028 Warning Step 5 Insert the new power supply into the power supply slot and gently push it into the slot The 1025 W power supply modu...

Страница 5: ...een Step 9 Repeat the steps to install a second power supply When you install the second power supply the LEDs on the power supply might blink momentarily Note Finding the Serial Number If you contact Cisco Technical Assistance you need to know the switch serial number You can also use the show version privileged EXEC command to see the switch serial number Figure 5 1025 W AC Power Supply Serial N...

Страница 6: ...Catalyst 6800IA Switch Hardware Installation Guide 6 OL 30278 02 Power Supply Installation Finding the Serial Number ...

Отзывы: