![Cisco PA-2E3 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/cisco/pa-2e3/pa-2e3_installation-and-configuration-manual_63524017.webp)
1-5
PA-E3 Serial Port Adapter Installation and Configuration
OL-3502-04
Chapter 1 Overview
Management Information Base
Note
For E3 (75-ohm) connections, you must have ferrite beads on the 75-ohm coaxial cable and EMI
decoupling clips on the receive end of the cable (see
) if compliance with European
certification standards for emission control is required (EN55022/CISPR22 Class B for radiated
emission levels).
Figure 1-5
PA-E3 Cables
You can test the DTE-to-DCE cable connection by using the loopback dte command. See the
loopback Commands” section on page 4-29
for more information.
Management Information Base
Management Information Base (MIB) attributes are readable and writable across the ILMI through use
of SNMP.
The one-port PA-E3 supports MIB-II (RFC 1213) and the E3 interface MIB (RFC 1407).
The two-port PA-2E3 supports MIB-II (RFC 1213) and the E3 interface MIB (RFC 1407).
Port Adapter Slot Locations on the Supported Platforms
The following sections provide port adapter slot locations and related information:
•
Catalyst RSM/VIP2 Slot Numbering, page 1-6
•
Catalyst 6000 Family FlexWAN Module Slot Numbering, page 1-7
•
Cisco 7100 Series Routers Slot Numbering, page 1-8
•
Cisco 7200 Series Routers and Cisco 7200 VXR Routers Slot Numbering, page 1-9
•
Cisco uBR7200 Series Router Slot Numbering, page 1-10
•
Cisco 7201 Router Slot Numbering, page 1-11
•
Cisco 7301 Router Slot Numbering, page 1-11
•
Cisco 7304 PCI Port Adapter Carrier Card Slot Numbering, page 1-12
•
Cisco 7401ASR Router Slot Numbering, page 1-13
•
Cisco 7000 Series Routers and Cisco 7500 Series Routers VIP Slot Numbering, page 1-13
RCLK
XMTR
RCVR
FERF
T3
OOF
AIS
H10314
EMI decoupler clip
Ferrite beads