4-22
PA-2CE1 Channelized E1 Port Adapter Installation and Configuration
OL-3519-01
Chapter
Checking the Configuration
VIP2 in Cisco 7000 Series and Cisco 7500 Series Routers
Following is an example of the show controllers e1 command that shows the status of a PA-2CE1
installed in port adapter slot 1 on a VIP2 in interface processor slot 3:
Router# show controllers e1
E1 3/1/0 is up.
Applique type is Channelized E1 - unbalanced
No far end block errors detected
No alarms detected.
Framing is CRC4, Line Code is HDB3, Clock Source is Line.
Data in current interval (700 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Data in Interval 1:
10 Line Code Violations, 1 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 2 Line Err Secs, 0 Degraded Mins
1 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 1 Unavail Secs
Total Data (last 1 15 minute intervals):
10 Line Code Violations, 1 Path Code Violations,
0 Slip Secs, 0 Fr Loss Secs, 2 Line Err Secs, 0 Degraded Mins,
1 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 1 Unavail Secs
E1 3/1/1 is up.
Applique type is Channelized E1 - unbalanced
No far end block errors detected
No alarms detected.
Framing is CRC4, Line Code is HDB3, Clock Source is Line.
Data in current interval (700 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Data in Interval 1:
10 Line Code Violations, 1 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 2 Line Err Secs, 0 Degraded Mins
1 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 1 Unavail Secs
Total Data (last 1 15 minute intervals):
10 Line Code Violations, 1 Path Code Violations,
0 Slip Secs, 0 Fr Loss Secs, 2 Line Err Secs, 0 Degraded Mins,
1 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 1 Unavail Secs
Proceed to the next section, “Using the ping Command to Verify Network Connectivity” to check
network connectivity of the PA-2CE1 and switch or router.