B.4.6 32MUX-O Card Specifications
B.4.6 32MUX-O Card Specifications
The 32 MUX-O card optical specifications are listed in
Note
For power specifications, refer to the
“16.1.7 Multiplexer, Demultiplexer, and OADM Card Interface
The 32MUX-O card has the following additional specifications:
•
Environmental
–
Operating temperature:
C-Temp: –5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–
Operating humidity: 5 to 95 percent relative humidity (RH)
•
Dimensions
–
Height: 12.65 in. (321.3 mm)
–
Width: 1.84 in. (46.8 mm)
–
Depth: 9.00 in. (228.6 mm)
B.4.7 32DMX-O Card Specifications
The 32DMX-O card optical specifications are listed in
Note
For power specifications, see the
“16.1.7 Multiplexer, Demultiplexer, and OADM Card Interface
Table B-3
32MUX-O Optical Specifications
Parameter
Note
Condition
Min
Max
Unit
Tx filter shape (–1 dB
bandwidth)
All standard operating
procedures (SOP) and
within whole operating
temperature range
In 1/32—Out beginning
of life (BOL)
+/–180
+/–300
pm
In 1/32—Out end of life
(EOL)
+/–160
+/–300
pm
Insertion loss
All SOP and within
whole operating
temperature range
In 1/32—Out BOL
4
8.0
dB
In 1/32—Out EOL
4
8.5
dB
VOA dynamic range
—
—
25
—
dB
Optical monitor
tap-splitting ratio on
monitor port
Optical monitor port
with respect to output
port in multiplexer
only
—
19
21
dB
Maximum optical
input power
—
—
300
—
mW