4-11
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
78-19416-01
Chapter 4 Turn Up a Network
Before You Begin
NTP-H32 Path Protection Acceptance Test
Step 1
Complete the
“DLP-H29 Log into CTC” task on page 16-43
. If you are already logged in, continue with
Step 2.
Step 2
From the View menu choose
Go to Network View
.
Step 3
Click the
Alarms
tab and click Synchronize.
a.
Verify that the alarm filter is not on. See the
“DLP-H88 Disable Alarm Filtering” task on
as necessary.
b.
Verify that no unexplained alarms appear on the network. If alarms are present, investigate and
resolve them before continuing. Refer to the
Cisco ONS 15310-MA SDH Troubleshooting Guide
if
necessary.
c.
Complete the
“DLP-H223 Export CTC Data” task on page 18-20
to export alarm data to a file on
your hard drive.
Step 4
On the Conditions tab, and click Retrieve.
a.
Verify that the network does not have any unexplained conditions. If unexplained conditions are
present, resolve them before continuing. Refer to the
Cisco ONS 15310-MA SDH Troubleshooting
Guide
if necessary.
b.
Complete the
“DLP-H223 Export CTC Data” task on page 18-20
to export condition data to a file
on your hard drive.
Step 5
On the network map, double-click the node that you logged into in Step
Step 6
Create a test circuit from that node to the next adjacent path protection node.
•
For E1 circuits, complete the
“NTP-H37 Create an Automatically Routed E1 Circuit” procedure on
. When you set the circuit state, choose
unlocked
and check the
Apply to drop ports
check
box.
•
For DS3/E3 circuits, complete the
“NTP-H40 Create an Automatically Routed DS-3 or E3 Circuit”
. When you set the circuit state, choose
unlocked
and check the
Apply to
drop ports
check box.
•
For STM-M circuits, complete the
“NTP-H47 Create an Automatically Routed Optical Circuit”
. When you set the circuit state, choose
unlocked
and check the
Apply to
drop ports
check box.
Step 7
For the ONS 15310-MA SDH, configure the test set for the test circuit type you created:
•
Wideband Electrical ports (WBE) E1—On the ONS 15310-MA SDH, if you are testing an unmuxed
E1, use the Champ connectors on the BICs on the rear of the chassis. Set the test set for E1. For
information about configuring your test set, consult your test set user guide.
Purpose
This procedure tests an Path Protection configuration.
Tools/Equipment
Test set and cables appropriate to the test circuit you will create
Prerequisite Procedures
NTP-H31 Provision Path Protection Nodes, page 4-9
Required/As Needed
As needed
Onsite/Remote
Onsite
Security Level
Provisioning or higher
Содержание ONS 15310-MA SDH
Страница 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Страница 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 290: ...15 4 Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Chapter 15 Power Down the Node ...