Dell EMC recommended switch configuration 

Use the following steps to configure the Cisco Nexus 9372PX switch. 

Note:

 The configuration steps in this section are only recommended when the switch is used as a dedicated 

SAN for iSCSI traffic (not shared with LAN traffic). 

2.1 

Hardware configuration  

1.  Power on the chassis.  
2.  Connect a serial cable to the active supervisor management port. 
3.  Using PuTTY or another terminal utility, open a serial connection session to the switch. 
4.  Open a terminal emulator and configure it to use the serial port (usually COM1 but this may vary 

depending on your system). Configure serial communications for 9600,N,8,1 and no flow control. 

2.2 

Delete startup configuration 

Note:

 This example assumes a switch at its default configuration settings.  Using the 

write erase

 

command will set the startup configuration file to its default settings. Always back up the configuration 
settings prior to performing any configuration changes  

switch#

write erase 

Warning: This command will erase the startup-configuration 
Do you wish to proceed anyway ? (y/n) [n]

switch#

reload 

This command will reboot the system 
Do you want to continue? (y/n) [n]

Note:

 The switch will reboot. 

 

 

Содержание Nexus 9372PX

Страница 1: ...A Dell EMC Deployment and Configuration Guide Cisco Nexus 9372PX Switch Configuration Guide for Dell PS Series SANs Dell EMC Engineering June 2017 ...

Страница 2: ...tness for a particular purpose Use copying and distribution of any software described in this publication requires an applicable software license 2017 Dell Inc or its subsidiaries All Rights Reserved Dell EMC Dell EMC and other trademarks are trademarks of Dell Inc or its subsidiaries Other trademarks may be trademarks of their respective owners Dell believes the information in this document is ac...

Страница 3: ...2 2 Delete startup configuration 6 2 3 Run the basic system configuration 7 2 4 Enable LLDP 8 2 5 Disable Data Center Bridging DCB 8 2 6 Configure the vPC domain 8 2 7 Configure the Port Channel 9 2 8 Enable Jumbo Frames on edge ports 9 2 9 Enable link level flow control 802 3x on edge ports 9 2 10 Configure portfast on edge ports 10 2 11 Enable switch ports 10 2 12 Save configuration 10 2 13 Conf...

Страница 4: ...ssword Italic brackets Separate variables ip address mask 1 2 Audience This switch configuration guide describes a verified configuration following Dell EMC best practices for a dedicated PS Series iSCSI SAN and is intended for storage or network administrators and deployment personnel 1 3 Switch details Table 2 provides an overview of the switch configuration Switch specifications Cisco Nexus 937...

Страница 5: ... Switch Configuration Guide for Dell PS Series SANs SCG3665 1 4 Cabling diagram The cabling diagram shown in Figure 1 represents the method recommended by Dell EMC for deploying servers and PS Series arrays Cabling diagram ...

Страница 6: ...on session to the switch 4 Open a terminal emulator and configure it to use the serial port usually COM1 but this may vary depending on your system Configure serial communications for 9600 N 8 1 and no flow control 2 2 Delete startup configuration Note This example assumes a switch at its default configuration settings Using the write erase command will set the startup configuration file to its de...

Страница 7: ...r may affect response times for initial service calls Nexus9000 devices must be registered to receive entitled support services Press Enter at anytime to skip a dialog Use ctrl c at anytime to skip the remaining dialogs Would you like to enter the basic configuration dialog yes no yes Create another login account yes no n n Configure read only SNMP community string yes no n n Configure read write ...

Страница 8: ...e Data Center Bridging DCB All steps in this section are required in order to properly disable DCB Note By default DCB is enabled This document provides steps to disable DCB Perform all operations during a maintenance window because a temporary loss of communication between host servers and storage arrays may occur switch config lldp tlv select dcbxp switch config copy running config startup confi...

Страница 9: ...fig if no shutdown switch config if exit 2 8 Enable Jumbo Frames on edge ports switch config system jumbomtu 9216 switch config interface ethernet 1 1 48 switch config if range mtu 9216 2 9 Enable link level flow control 802 3x on edge ports Perform this step for each individual port that is connected to a storage controller or a host server interface port or specify a range of ports to configure ...

Страница 10: ...temporary bridging loops Use with CAUTION Edge Port Type Portfast will be configured in 96 interfaces due to the range commend but will only have effect when the interfaces are in a non trunking mode 2 11 Enable switch ports The following example enables a range of ports If preferred enable individual ports as needed switch config if range shutdown switch config if range no shutdown switch config ...

Страница 11: ...is an online technical community where IT professionals have access to numerous resources for Dell EMC software hardware and services Storage Solutions Technical Documents on Dell TechCenter provide expertise that helps to ensure customer success on Dell EMC Storage platforms A 1 Related resources Referenced or recommended Dell EMC publications Dell PS Series Configuration Guide Dell EMC Storage C...

Отзывы: