background image

Removing a DC Power Supply

You can remove one power supply while the other one provides power to the switch.

To disconnect the power supply from its power cables, you must shut off the power from the power source
and then either disconnect a connector for the power cables or release each of three cables from the power
supply (requires a standard screw driver).

Step 1

Turn off the circuit breaker for the power feed to the power supply that you are replacing.

Be sure that the LEDs turn off on the power supply that you are removing.

Step 2

Remove the power cable from the power supply by doing the following:

• To remove an orange power cable connector from a 48-V DC power supply, do the following:

a.

Push the orange plastic button on the top of the connector block inward toward the power supply.

b.

Pull the connector block out of the power supply.

• To remove an Anderson Power Products Saf-D-Grid power cable connector from a high-voltage power supply, press

on the tab at the top of the Saf-D-Grid connector and pull the connector out of the power supply.

Step 3

Grasp the power supply handle while pressing the release latch towards the power supply handle.

Step 4

Pull the power supply out of the bay.

What to do next

You are ready to install a DC power supply in the open slot.

Installing an AC Power Supply

You can replace one power supply while the other one provides power to the switch.

Before you begin

• The power supply that you are installing must be capable of using the same airflow direction as the fan

trays installed in the same switch and it must use the same type of power source as the other power supply
installed in the same switch (do not mix AC and DC power supplies in the same switch).

DC power supplies with green coloring have the same port-side intake airflow
direction as the power supplies with red coloring, and DC power supplies with
gray coloring have the same port-side exhaust airflow direction as the power
supplies with blue coloring. HVAC/HVDC power supplies automatically use the
same airflow direction as the installed fan modules. If the power supply that you
are replacing has a different color handle than the replacement power supply,
verify that it has or will have the same airflow direction as the other modules in
the switch.

Note

Replacing Modules

4

Replacing Modules

Removing a DC Power Supply

Содержание Nexus 93108TC-EX

Страница 1: ... in air from a cold aisle and exhausts to a hot aisle Otherwise the switch can overheat and shutdown If you are changing the airflow direction of all the modules in the chassis you must shutdown the switch before replacing all the fan and power supply modules with modules using the other airflow direction During operations all of the modules must have the same direction of airflow Caution Removing...

Страница 2: ...requires two power supplies for redundancy With one power supply providing the necessary power for operations you can replace the other power supply during operations so long as the new power supply has the same airflow direction as the other modules in the chassis You can replace a power supply with another supported power supply that has the same power source type and the same wattage rating as ...

Страница 3: ...ly Removing an HVAC HVDC Power Supply You can remove one power supply while the other one provides power to the switch To disconnect the power supply from its power cables you must shut off the power from the power source and then either disconnect a connector for the power cables or release each of three cables from the power supply requires a standard screw driver Step 1 Turn off the circuit bre...

Страница 4: ...the power supply handle while pressing the release latch towards the power supply handle Step 4 Pull the power supply out of the bay What to do next You are ready to install a DC power supply in the open slot Installing an AC Power Supply You can replace one power supply while the other one provides power to the switch Before you begin The power supply that you are installing must be capable of us...

Страница 5: ... until it clicks in place Step 3 Attach the power cable to the electrical outlet on the front of the power supply Step 4 Make sure that the other end of the power cable is attached to the appropriate power source for the power supply Depending on the outlet receptacle on your power distribution unit you might need the optional jumper cable to connect the switch to your outlet receptacle Note Step ...

Страница 6: ...lectrical connector block insert the block into the power receptacle on the power supply If the electrical cables have not been connected to the electrical connector block wire them as described in Wiring a 48 V DC Electrical Connector Block on page 7 Step 4 Make sure that the other end of the power cable is connected to the appropriate power source for the power supply Step 5 If using a DC power ...

Страница 7: ...block insert the block into the power receptacle on the power supply If the electrical cables have not been connected to the electrical connector block wire them as described in Wiring a 48 V DC Electrical Connector Block on page 7 Step 3 Turn on the circuit breaker for the DC power source connected to the power supply Step 4 Verify that the power supply is operational by making sure that the powe...

Страница 8: ...turn DC cable 3 Step 5 Use a small screwdriver to depress the spring loaded wire retainer lever on the lower spring cage wire connector Insert your green ground wire into the aperture and then release the lever Step 6 Use a small screwdriver to depress the spring loaded wire retainer lever on the middle spring cage wire connector Insert your black DC negative wire into the aperture and then releas...