When you replace a card an identical card, you do not need to make any changes to the database.
Note
If the troubleshooting procedure does not clear the alarm, log into the Technical Support Website at
or call the Cisco Technical Assistance Center (1 800 553-2447) to report the problem.
UNQUAL-PPM
Default Severity: Not Reported (NR), Non-Service-Affecting (NSA)
Logical Objects: PPM
The Unqualified PPM Inserted condition occurs when a PPM with a nonqualified product ID is plugged into
the card port; that is, the PPM passes the security code check as a Cisco PPM but is not qualified for use on
the particular card.
Clear the UNQUAL-PPM Condition
SUMMARY STEPS
1.
Obtain the correct Cisco PPM and replace the existing PPM with the new one.
DETAILED STEPS
Obtain the correct Cisco PPM and replace the existing PPM with the new one.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
UNREACHABLE-TARGET-POWER
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: OCH
The Unreachable Port Target Power alarm occurs on WSS32 cards during startup as the card laser attains its
correct power level. The condition disappears when the card successfully boots.
Card power levels are listed in the
document.
Note
UNREACHABLE-TARGET-POWER is an informational condition. It only requires troubleshooting if it
does not clear.
Note
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
427
Alarm Troubleshooting
UNQUAL-PPM