DETAILED STEPS
Complete the
Replace the Alarm Interface Panel, on page 461
procedure.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical Support
Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or log into
en/us/support/web/tsd-cisco-worldwide-contacts.html
to obtain a directory of toll-free Technical Support numbers for
your country.
MEA (PPM)
Default Severity: Critical (CR), Service-Affecting (SA)
Logical Object: PPM
The Missing Equipment Attributes alarm for the PPM (SFP) is raised on TXP, MXP, MRC-12 and
OC192-XFP/STM-64-XP cards when the PPM (SFP) is misprovisioned or unsupported. It can occur when
you provision the PPM (SFP) for a wavelength that is explicitly not the first tunable wavelength.
When the TNCS-2 card is replacing the TNC card pre-provisioned with OC3 payload on a chassis, the
PROV-MISMATCH/MEA alarm is raised. Delete the pre-provisioning on the TNCS-2 card to proceed.
Note
Clear the MEA (PPM) Alarm
SUMMARY STEPS
1.
To provision the PPM (SFP), you must first create it in CTC. To do this, complete the following steps:
2.
After you have created the PPM (SFP), or if you see it listed in the Pluggable Port Modules area but not
in the Selected PPM area, choose the port rate:
3.
If you see the port listed in the Pluggable Port Modules area and the Selected PPM area, the MEA indicates
that the incorrect port rate was selected. Click the port in the Selected PPM area and click Delete.
4.
Complete
to correctly provision the port rate.
DETAILED STEPS
Step 1
To provision the PPM (SFP), you must first create it in CTC. To do this, complete the following steps:
a) In node view (single-shelf mode) or shelf view (multishelf mode), double-click the reporting card to open the card
view.
b) Click the
Provisioning
>
Pluggable Port Modules
tabs. (If you already see the PPM [SFP] listed in the Pluggable
Port Modules Area, go to
.)
c) Under the Pluggable Port Modules area, click
Create
.
d) In the Create PPM dialog box, choose the card PPM (SFP) number from the drop-down list (for example, PPM 1).
e) Choose the PPM (SFP) type from the second drop-down list, for example PPM (1 Port).
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
303
Alarm Troubleshooting
MEA (PPM)