FSTSYNC
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: NE-SREF
A Fast Start Synchronization Mode condition occurs when the node is choosing a new timing reference. The
previous timing reference has failed.
The FSTSYNC alarm disappears after approximately 30 seconds.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/
for more information or call Cisco TAC (1 800 553-2447).
FSTSYNC is an informational condition. It does not require troubleshooting.
Note
FTA-MISMATCH
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Fan Tray Mismatch condition is raised on the ADM-10G card and OTU2_XP. It indicates that an
unsupported version of the fan tray assembly is installed in the shelf. The ADM-10G and OTU2_XP card
must be installed in a shelf that has FTA version 4 or higher.
Clear the FTA-MISMATCH Condition
SUMMARY STEPS
1.
Obtain the correct fan tray assembly, and replace the existing FTA with the new one by following the
Replace the Fan-Tray Assembly, on page 460
procedure.
DETAILED STEPS
Obtain the correct fan tray assembly, and replace the existing FTA with the new one by following the
procedure.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).