MGX8850.7.PXM.a>dspdiagresults
shows some of the other commands that can be used to isolate and troubleshoot problems. For
details about these commands refer to the Cisco MGX 8850 (PXM45/PXM1E), Cisco MGX 8950, Cisco
MGX 8830, and Cisco MGX 8880 Command Reference, Release 5.
Diagnostics Examples
The following example shows the display output for the dspdiagresults command:
MGX8850.7.PXM.a>
dspdiagresults
--------------------------------------------------------
Online Diagnostics Test Summary
--------------------------------------------------------
Id Name En #Att #Fail #Pass Alarm Result
-- ---- -- ---- ----- ----- ----- -----
1 Data Path Y 2868 0 2868 None Pass
2 Trap Freq Monitor Y 1434 0 1434 None Pass
3 Memory Access Y 2868 0 2868 None Pass
4 Atlas Reg Access Y 2868 0 2868 None Pass
5 Atlas Sram Access Y 2868 0 2868 None Pass
6 Framer/LIU Access Y 2868 0 2868 None Pass
7 Elmer Access Y 2868 0 2868 None Pass
8 Flash CheckSum Y 2868 0 2868 None Pass
9 Ethernet Ping Y 2868 0 2868 None Pass
10 QE RAM Access Y 2868 0 2868 None Pass
Table G-1
RAS-Related Diagnostics, Alarm, and POST Commands
Command
Description
cnfdiag
Configures (enables/disables) online diagnostics and schedules offline
diagnostics for a specific slot.
cnfdiagall
Configures (enables/disables) online diagnostics and schedules offline
diagnostics for all slots.
dspdiagcnf
Displays the configuration of online and offline diagnostics
dspdiagstatus
Displays the status of online and offline diagnostics on all slots and indicates
whether diagnostics is ready to be enabled or not.
dspdiagstat
Displays the statistics of online and offline diagnostics execution for a specific
slot.
dspdiagerr
Displays errors of online and offline diagnostics execution on all slots.
dspdiagtests
Displays a list of all diagnostics tests.
clrdiagstat
Clears the statistics of executed online and offline diagnostics for a specific slot.
clrdiagerr
Clears the errors reported by online and offline diagnostics for a specific slot.
dspdeverr
Displays the error types and error counts for a specific device in a slot.
abortofflinediag
Stops the currently running offline diagnostics test.
dspdeverrhist
Displays the history of error types and error counts for a specific device in a slot.
dspdiagresults
Displays the diagnostics test results and alarm conditions for a specific slot.
dsphwalms
Displays a summary of errors and alarms for all devices in a slot.
dsppostresults
Displays the Power on Self Test (POST) results.