4.2.3 Mount the MR52

4.2.2.3 Powering the MR52 with an 802.3at Power over Ethernet Switch 

Route Ethernet cable from a port on an active 802.3at PoE switch to the Eth0 port in the bay of the MR52.

The MR52 is Gigabit Ethernet-capable. To maximize device performance, a Gigabit-capable 
switch should be used.

Содержание Meraki MR52

Страница 1: ...Meraki MR52 Hardware Installation Guide ...

Страница 2: ...est of improving internal design operational function and or reliability Cisco Systems reserves the right to make changes to the products described in this document without notice Cisco Systems does not assume any liability that may occur due to the use or application of the product s or circult layout s described herein Warranty Meraki Inc provides a lifetime warranty on this product Warranty det...

Страница 3: ...allation 10 4 Installation Instructions 11 4 1 Choose Your Mounting Location 11 4 2 Install the MR52 11 4 2 1 Attach the Mount Plate 11 4 2 1 1 Wall or Solid Ceiling Mount Using Mount Plate 13 4 2 1 2 Drop Ceiling Mount Using Mount Plate 14 4 2 1 3 Electrical Junction Box Mount Using Mount Plate 18 4 2 2 Power the MR52 20 4 2 2 1 Powering the MR52 with Meraki AC Adapter 21 4 2 2 2 Powering the MR5...

Страница 4: ...nt and Related Publications The MR52 Hardware Installation Guide describes the installation procedure for the MR52 indoor access point Additional reference documents are available online at www meraki com library product ...

Страница 5: ...en connected to the Meraki Cloud Control ler the MR52 enables the creation of ultra high speed reliable indoor wireless networks quickly easily and cost effectively 2 1 Package Contents The MR52 package contains the following 2 2 Understanding the MR52 MR52 Operation Temperature 32 F to 104 F 0 C to 40 C Your Meraki MR52 has the following features Kensington lock hard point Security screws Wall sc...

Страница 6: ...ount plate attachment slots 2x Access point mounting posts 2x Desk mount feet 4x Cable access bay AC Adapter plug sold separately Power supplied by adapter 12Vdc 2 5A Ethernet 0 port 10 100 1000 Power supplied by PoE 37 57 Vdc 0 6A Factory Reset Button Various mounting holes ...

Страница 7: ...ructure using a standard Kensington lock 2 4 Ethernet Ports The MR52 features a Gigabit Ethernet RJ45 port that accepts 802 3at power labeled PoE This port should be used for uplink to your WAN connection 2 5 Power Source Options The MR52 access point can be powered using either the Meraki AC Adapter or 802 3at PoE Injector both sold separately or a third party 802 3at PoE switch 2 6 Factory Reset...

Страница 8: ...com 4 Go to the map floor plan view and place each AP on the map by clicking and dragging it to the location where you plan to mount it 3 2 Check and Upgrade Firmware To ensure your MR52 performs optimally immediately following installation Meraki recommends that you facilitate a firmware upgrade prior to mounting your MR52 1 Attach your MR52 to power and a wired Internet connection See p 19 of th...

Страница 9: ...itch plug an Ethernet cable into the MR52 s Ethernet jack and the other end into a PoE switch Then connect the client machine over Ethernet cable to the PoE switch If using a Meraki PoE Injector connect the MR52 to the PoE port of the Injector and the client machine to the LAN port 2 Using a web browser on the client machine access the AP s built in web server by browsing to http my meraki com Alt...

Страница 10: ...l Hardware for Installation 802 3at PoE power source either PoE switch or Meraki 802 3at PoE Injector Network cables with RJ45 connectors long enough for your particular mounting location 3 5 Collect Tools You will need the following tools to perform an installation AC Adapter or ...

Страница 11: ...brary product 4 2 Install the MR52 For most mounting scenarios the MR52 mount plate provides a quick simple and flexible means of mounting your device The installation should be done in two steps First install the mount plate to your selected location Then attach the MR52 to the mount plate 4 2 1 Attach the Mount Plate The MR52 mount plate can be used to install your access point in a wide range o...

Страница 12: ...ing included screws attach the mount plate to your mounting wall or ceiling It is recommended that the MR52 be mounted to a wall or solid ceiling using the mount plate for physical security reasons If mounting your MR52 to a wall skip to Power the MR52 on P 20 ...

Страница 13: ...ount Using Mount Plate To mount your MR52 on a drop ceiling T rail use the included drop ceiling mounting accessory kit The accessory kit can be used to mount to most 9 16 15 16 or 1 T rails Dropped ceiling mounting clips with set screws 6 32x4 mm screws 6 32x7 mm screws Only used for recessed rail mount uncommon 2 rubber spacers Only used for recessed rail mount uncommon The kit contains ...

Страница 14: ...the set screws on the T rail clips to secure the clips using a 5 64 2 mm hex key 2 Using the dashed lines on the mount plate template as a guide set the proper spacing of the T rail clips on the T rail Set screws x4 ...

Страница 15: ...s marked with a T To select the correct set of mounting hardware to use first determine whether you are mounting to a flush or recessed rail See below images for clarification Flush T rail Recessed T rail T rail flush with tiles T rail recessed from tiles Ceiling tiles T rail ...

Страница 16: ... be mounted to a 4 square cable junction box a 3 5 or 4 round cable junction box or various U S and European outlet boxes mounting screws are not included Using appropriate mounting hardware for your specific type of junction box attach the mount plate to the junction box ...

Страница 17: ...2 If mounting to an electrical junction box feed the Ethernet cable through the cable access hole in the Mount Plate If mounting to a wall or ceiling the Ethernet cable will feed through the cable slot on bottom of the MR52 ...

Страница 18: ...ion into the Eth0 port on the MR52 4 2 2 2 Powering the MR52 with the Meraki 802 3at Power over Ethernet Injector sold separately 1 Plug the power cord into the PoE Injector and the other end into wall power 2 Plug an Ethernet cable that is connected to an active Ethernet connection into the IN port on the injector 3 Route Ethernet cable from the OUT port on the injector to the Eth0 port in the ca...

Страница 19: ...th an 802 3at Power over Ethernet Switch Route Ethernet cable from a port on an active 802 3at PoE switch to the Eth0 port in the bay of the MR52 The MR52 is Gigabit Ethernet capable To maximize device performance a Gigabit capable switch should be used ...

Страница 20: ...ceiling or electrical junction box mount where you have already installed the mount plate Insert the top latch on the mount plate into the top mount plate attachment slots on the back of the device Rotate the bottom of the unit into the bottom ount plate attachment slot The unit will click into place ...

Страница 21: ...21 4 2 3 3 Desk or Shelf Mount The MR52 can be placed on a desk or shelf resting on the non scratch rubber feet The mount plate is not necessary for a desk or shelf mounting ...

Страница 22: ...x and phillips head security screws are included choose one and or Kensington lock If the mount plate was not used the MR52 can still be secured using a Kensington lock 4 3 1 Security Screw Install the security screw in the lower mount plate tab 4 3 2 Kensington Lock Attach a Kensington lock cable to the access point at the hard point on the side of the device Attach the other end of the cable to ...

Страница 23: ...nable protection against harmful interference in a residen tial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful inte...

Страница 24: ...l interference to co channel mobile satellite systems ii high power radars are allocated as primary users i e priority users of the bands 5250 5350 MHz and 5650 5850 MHz and that these radars could cause interference and or damage to LE LAN devices Avertissement i les dispositifs fonctionnant dans la bande 5 150 5 250 MHz sont réservés uniquement pour une utilisation à l intérieur afin de réduire ...

Страница 25: ...25 www ciscosystems com Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 USA ...

Отзывы: