background image

 

 

 
 

 

 

 
 

 

 

 

 

 

 

 
 

 

 

 
 

 

 
 

 

 
 

Содержание MERAKI MR46E-HW

Страница 1: ......

Страница 2: ...Meraki MR46E HW Hardware Installation Guide ...

Страница 3: ...erest of improving internal design operational function and or reliability Cisco Systems reserves the right to make changes to the products described in this document without notice Cisco Systems does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein Warranty Meraki Inc provides a lifetime warranty on this product Warranty d...

Страница 4: ...10 4 Installation Instructions 11 4 1 Choose Your Mounting Location 11 4 2 Install the MR46E HW 11 4 2 1Attach the Mount Plate 11 4 2 1 1 Wall or Solid Ceiling Mount Using Mount Plate 13 4 2 1 2 Drop Ceiling Mount Using Mount Plate 14 4 2 1 3Electrical Junction Box Mount Using Mount Plate 18 4 2 2 Power the MR46E HW 20 4 2 2 1Powering the MR46E HW with Meraki AC Adapter 21 4 2 2 2 Powering the MR4...

Страница 5: ...nd Related Publications The MR46E HW Hardware Installation Guide describes the installation procedure for the MR46E HW indoor access point Additional reference documents are available online at www meraki com library product ...

Страница 6: ...n of ultra high speed reliable indoor wireless networks quickly easily and cost effectively 2 1 Package Contents The MR46E HW package contains the following MR46E HW access point Mounting plate Drop ceiling mounting kit wall screws Security screws Mounting Template 2 2 Understanding the MR46E HW MR46E HW Operation Temperature 32 F to 104 F 0 C to 40 C Your Meraki MR46E HW has the following feature...

Страница 7: ...y Factory Reset Button Ethernet port Power supplied by PoE 50 57Vdc 0 6A AC Adapter plug sold separately Power supplied by adapter 12Vdc 2 5A Your MR46E HW mount plate has the following features Access point mounting posts 2x Various mounting holes ...

Страница 8: ...ucture using a standard Kensington lock 2 4 Ethernet Ports The MR46E HW features an Ethernet RJ45 port that accepts 802 3at power labeled PoE This port should be used for uplink to your WAN connection 2 5 Power Source Options The MR46E HW access point can be powered using either the Meraki AC Adapter or 802 3at PoE Injector both sold separately or a third party 802 3at PoE switch 2 6 Factory Reset...

Страница 9: ...Go to the map floor plan view and place each AP on the map by clicking and dragging it to the location where you plan to mount it 3 2 Check and Upgrade Firmware To ensure your MR46E HW performs optimally immediately following installation Meraki recommends that you facilitate a firmware upgrade prior to mounting your MR46E HW 1 Attach your MR46E HW to power and a wired Internet connection See p 19...

Страница 10: ...E switch plug an Ethernet cable into the MR46E HW s Ethernet jack and the other end into a PoE switch Then connect the client machine over Ethernet cable to the PoE switch If using a Meraki PoE Injector connect the MR46E HW to the PoE port of the Injector and the client machine to the LAN port 2 Using a web browser on the client machine access the AP s built in web server by browsing to http my me...

Страница 11: ...ion Phillips screwdriver Hammer Drill with 1 4 6 3mm bits 3 6 Collect Additional Hardware for Installation 802 3at PoE power source either PoE switch or Meraki 802 3at PoE Injector AC Adapter Network cables with RJ45 connectors long enough for your particular mounting location or ...

Страница 12: ...E HW For most mounting scenarios the MR46E HW mount plate provides a quick simple and flexible means of mounting your device The installation should be done in two steps First install the mount plate to your selected location Then attach the MR46E HW to the mount plate This equipment is only suitable for mounting at heights 2 m 4 2 1 Attach the Mount Plate The MR46E HW mount plate can be used to i...

Страница 13: ...cluded screws attach the mount plate to your mounting wall or ceiling It is recommended that the MR46E HW be mounted to a wall or solid ceiling using the mount plate for physical security reasons If mounting your MR46E HW to a wall skip to Power the MR46E HW on P 20 ...

Страница 14: ...most 9 16 15 16 or 1 T rails The kit contains Dropped ceiling mounting clips with set screws 6 32x4 mm screws 6 32x7 mm screws Only used for recessed rail mount uncommon 2 rubber spacers Only used for recessed rail mount uncommon 1 Attach the T rail clips to the T rail by rotating them and snapping them into place as shown The black foam pads should be compressed slightly after installation ...

Страница 15: ...14 ...

Страница 16: ...sing the dashed lines on the mount plate template as a guide set the proper spacing of the T rail clips on the T rail 3 Tighten the set screws on the T rail clips to secure the clips using a 5 64 2 mm hex key ...

Страница 17: ...16 4 Attach the mount plate to the T rail clips using the mount plate holes marked with a T FlushT rail Ceiling tiles T rail flush with tiles T rail recessed from tiles ...

Страница 18: ...utlet boxes mounting screws are not included Using appropriate mounting hardware for your specific type of junction box attach the mount 4 2 2 Power the MR46E HW If mounting to an electrical junction box feed the Ethernet cable through the cable access hole in the Mount Plate If mounting to a wall or ceiling the Ethernet cable will feed through the cable slot on bottom of the MR46E HW ...

Страница 19: ...n into the Eth0 port on the MR46E HW 4 2 2 2 Powering the M410 HW with the Meraki 802 3at Power over Ethernet Injector sold separately 1 Plug the power cord into the PoE Injector and the other end into wall power 2 Plug an Ethernet cable that is connected to an active Ethernet connection into the IN port on the injector 3 Route Ethernet cable from the OUT port on the injector to the Eth0 port in t...

Страница 20: ...Ethernet Switch Route Ethernet cable from a port on an active 802 3at PoE switch to the Eth0 port in the bay of the MR46E HW 4 2 3 Mount the MR46E HW The MR46E HW is Gigabit Ethernet capable To maximize device performance a Gigabit capable switch should be used ...

Страница 21: ...p ceiling or electrical junction box mount where you have already installed the mount plate Insert the top latch on the mount plate into the top mount plate attachment slots on the back of the device Rotate the bottom of the unit into the bottom ount plate attachment slot The unit will click into place ...

Страница 22: ...21 4 2 3 3 Desk or Shelf Mount The MR46E HW can be placed on a desk or shelf resting on the non scratch rubber feet The mount plate is not necessary for a desk or shelf mounting ...

Страница 23: ...ew Torx and phillips head security screws are included choose one and or Kensington lock If the mount plate was not used the MR46E HW can still be secured using a Kensington lock 4 3 1 Security Screw Install the security screw in the lower mount plate tab 4 3 2 Kensington Lock Attach a Kensington lock cable to the access point at the hard point on the side of the device Attach the other end of the...

Страница 24: ...ute to the Internet to check and upgrade its firmware 2 Verify access point connectivity Use any 802 11 client device to connect to the MR46E HW and verify proper connectivity using the client s web browser 3 Check network coverage Confirm that you have good signal strength throughout your coverage area You can use the signal strength meter on a laptop smart phone or other wireless device 5 Troubl...

Страница 25: ...Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation For product available in the USA Canada market only channel 1 11 can be operated Selection of other channels is not possible This device is restricted for indoor use IMPORTANT NOTE FCC...

Страница 26: ...ISCO MA ANT 3 C6 Omni antenna RP TNC 4 CISCO MA ANT 3 D6 Omni directional antenna RP TNC 5 CISCO MA ANT 3 E6 Wide patch antenna RP TNC 6 CISCO MA ANT 3 F6 Narrow patch antenna RP TNC Note1 Radio 1 2 4GHz Set Antenna Gain dBi Cable Loss dB True Gain dBi Port 1 Port 2 Port 3 Port 4 Port 1 Gray Port 2 Black Port 3 Blue Port 4 White Port 1 Port 2 Port 3 Port 4 1 3 80 3 80 3 80 3 80 1 01 0 41 0 41 1 00...

Страница 27: ...nt réservés uniquement pour une utilisation à l intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux For indoor use only Pour une utilisation en intérieur uniquement IMPORTANT NOTE IC Radiation Exposure Statement This equipment complies with IC RSS 102 radiation exposure limits set forth for an uncontrolled environment This...

Страница 28: ...USA ...