2-191
Cisco ME 3800X and ME 3600X Switch Command Reference
OL-28238-01
Chapter 2 Cisco ME 3800X and ME 3600X Switch Cisco IOS Commands
network-clock wait-to-restore
network-clock wait-to-restore
To configure the time that the switch waits before a previously failed Synchronous Ethernet (SyncE)
input clock must be fault-free before it is considered available as a synchronization source, use the
network-clock wait-to-restore
command in global configuration mode. To return to the default value,
use the no form of this command.
network-clock wait-to-restore
value
no network-clock wait-to-restore
value
Syntax Description
Defaults
SyncE wait to restore time is 300 seconds.
Command Modes
Global configuration
Command History
Usage Guidelines
None.
Examples
The following example shows how to configure the wait-to-restore time:
Switch#
configure terminal
Switch(config)#
network-clock wait-to-restore 50000
Related Commands
value
Sets the wait time in seconds. The range is 0 to 86400 seconds. The
default is 300 seconds.
Release
Modification
15.1(2)EY
This command was introduced.
Command Description
show network-clocks
Displays network clock configuration.
show network-clock
synchronization
Displays network clock configuration.
controller BITS
commands
Configures the BITS clock controller characteristics.
Содержание ME 3600X
Страница 14: ...Contents xiv Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 534: ... 100 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 Chapter xconnect ...
Страница 625: ...Index IN 15 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 626: ...Index IN 16 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 627: ...Index IN 17 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...
Страница 628: ...Index IN 18 Cisco ME 3800X and ME 3600X Switch Command Reference OL 28238 01 ...