Power Supply Requirement Specifications
The following table provides a sample calculation of power for the switch AC power supply:
Table 5: Power Dissipation for AC Power Supply
Power at
220 V/50
Hz
(Watts)
Power at
110 V/60
Hz
(Watts)
Fan
Trays
Optics
Number
Optics
Speed
Voltage
Temperature
Traffic
Rate
PSU
Power
Mode
107
110
4
8
32G-SW
Nominal
25°C
50%
2
Typical
130
134
4
24
113
116
4
8
64G-SW
146
150
4
24
109
112
4
8
32G-SW
25°C
100%
2
Max
132
136
4
24
32G-SW
115
118
4
8
64G-SW
148
152
4
24
64G-SW
153
158
4
24
32G-SW
40°C
166
171
4
24
64G-SW
Table 6: Power Supply Fuse Information
Fuse Melting Time
I2t (Amps
2
seconds)
Fuse Rating (Amp)
Fuse Type
PID
4 min@15 A
2 min@30 A
534
15
Time-lag
DS-CAC-500W-I
30 [email protected] A
0.15 s@50 A
660
DS-CAC-500W-E