background image

Figure 4: Mounting Screw Slots

Mounting screw slots (6)

1

Replacing the SD Flash Memory Card

Follow these steps to replace the SD flash memory card:

Step 1

Locate the flash memory card slot on the cable-side of the router.

Step 2

Loosen the captive thumb screw. (Be careful not to cross-thread or over-tighten the thumb screw.)

Step 3

Pull the cover open, and pull the cover tab from the hinge.

Step 4

Gently push the flash memory card to eject it. Place it in an anti-static bag to protect it from static discharge.

Step 5

Push the replacement card into the slot, and press it firmly in place. The card is keyed so that you cannot insert it the
wrong way.

Step 6

Place the flash card slot cover tabs into the hinge.

Step 7

Close the cover, and hand-tighten the screw.

Installing and Connecting the Router

7

Installing and Connecting the Router

Replacing the SD Flash Memory Card

Содержание IR8340

Страница 1: ... describes how to install and connect the Cisco IR8340 router For the optimum temperature ranges do not operate it in an area that less than the minimum of 40 C and exceeds a maximum recommended ambient temperature of 60 C Caution To view specifications for the Cisco Catalyst IR8340 Rugged Series Router see the IR8340 data sheet Note Only trained and qualified personnel should be allowed to instal...

Страница 2: ...oor before you slide the unit out for servicing Failure to stabilize the rack can cause the rack to tip over Statement 1048 Warning The chassis should be mounted on a rack that is permanently affixed to the building Statement 1049 Warning Blank faceplates and cover panels serve three important functions they prevent exposure to hazardous voltages and currents inside the chassis they contain electr...

Страница 3: ...047 Warning Hot surface Statement 1079 Warning Heat sinks applicable to warning statement 1079 can exceed 90º C in a 60º C ambient Suitable precautions should be taken to avoid burns Caution This equipment needs to be grounded Use a green and yellow 12 to 14 AWG ground wire to connect the host to earth ground during normal use Statement 242 Warning Before You Begin Before installing and connecting...

Страница 4: ...ter can only be mounted in a rack To prevent damage to the chassis never attempt to lift or tilt the chassis by holding it by the plastic panel on the front Always hold the chassis by the sides of the metal body Caution Allow at least one rack unit of vertical space above and below the router Note Rack Mounting the Chassis The Cisco IR8340 router can be installed in a 19 inch 48 26 cm standard rac...

Страница 5: ... to the Cisco IR8340 router remove the eight Phillips screws from the side panel and use them to attach the bracket to the router See the following figures Figure 2 Bracket Installation With Vertical Space Below the Router Installing and Connecting the Router 5 Installing and Connecting the Router Attaching Rack Mount Brackets to Cisco IR8340 Routers ...

Страница 6: ...ws provided with the rack to install the chassis in the rack The screw slots in the brackets are spaced to line up with every second pair of screw holes in the rack When the correct screw holes are used the small threaded holes in the brackets line up with unused screw holes in the rack If the small holes do not line up with the rack holes you must raise or lower the brackets to the next rack hole...

Страница 7: ...l the cover open and pull the cover tab from the hinge Step 4 Gently push the flash memory card to eject it Place it in an anti static bag to protect it from static discharge Step 5 Push the replacement card into the slot and press it firmly in place The card is keyed so that you cannot insert it the wrong way Step 6 Place the flash card slot cover tabs into the hinge Step 7 Close the cover and ha...

Страница 8: ... data bits No parity generated or checked 1 stop bit No Flow Control Console Port Signaling and Cabling with a DB 9 Adapter This section describes the console port signaling and cabling with a DB 9 adapter See the following figures Figure 5 RJ 45 Cable to DB 9 Female Adapter Figure 6 RJ 45 to RJ 45 Rollover Cable For the pinout descriptions for the DB 9 connections see Console Port Adapter Pinouts...

Страница 9: ...ts contain TNV circuits Some LAN and WAN ports both use RJ 45 connectors Use caution when connecting cables Statement 1021 Warning Hazardous network voltages are present in WAN ports regardless of whether power to the unit is OFF or ON To avoid electric shock use caution when working near WAN ports When detaching cables detach the end away from the unit first Statement 1026 Warning Connection Proc...

Страница 10: ...t the cables to make sure that the routing and bend radius is satisfactory Reposition cables if necessary Install cable ties in accordance with site requirements Note Installing and Connecting the Router 10 Installing and Connecting the Router Connection Procedures and Precautions ...

Отзывы: