Cables and Adapters
SFP Module Cables
Each port must match the wave-length specifications on each end of the cable, and for reliable communications,
the cable must not exceed the allowable length.
For more information about SFP/SFP+ modules and cables, see
.
Console Port Adapter Pinouts
The console port uses an 8-pin RJ-45 connector. If you did not order a console cable, you need to provide an
RJ-45-to-DB-9 adapter cable to connect the router console port to a PC console port. You need to provide an
RJ-45-to-DB-25 female DTE adapter if you want to connect the router console port to a terminal. You can
order an adapter (part number ACS-DSBUASYN=).
The following table shows the pinout descriptions for the DB-9 connections:
Table 14: Pinout Descriptions for the DB-9 Connections
Console Device
RJ-45 to DB-9
Terminal Adapter
RJ-45 to RJ-45 Rollover Cable
Console Port (DTE)
Signal
DB-9 Pin
RJ-45 Pin
RJ-45 Pin
Signal
CTS
8
8
1
RTS
DSR
6
7
2
DTR
RxD
2
6
3
TxD
GND
5
5
4
GND
GND
5
4
5
GND
TxD
3
3
6
RxD
DTR
4
2
7
DSR
RTS
7
1
8
CTS
3
Pin 1 is connected internally to Pin 8.