2-50
Cisco IE 3000 Switch Hardware Installation Guide
Chapter 2 Switch Installation
Connecting the Switch to the Power Converter
Step 3
Put the two modules together so that the power module fits in the switch recess.
Step 4
Push the upper module latches down and the lower module latches up to secure the power converter to
the switch. See
Figure 2-40
Pushing the Latches In
Installing the Power Converter on a DIN Rail, Wall, or Rack Adapter
You install the power converter on a DIN rail, wall, or rack as you would a switch module. You should
first attach the power converter to the switch and then install the entire switch assembly on the DIN rail,
wall, or rack adapter. For more information, see the
“Attaching the Power Converter to the Switch”
“Installing the Switch on a DIN Rail” section on page 2-27
Switch on the Wall” section on page 2-31
“Installing the Switch in a Rack” section on page 2-33
.
Warning
This equipment is supplied as “open type” equipment. It must be mounted within an enclosure that is
suitably designed for those specific environmental conditions that will be present and appropriately
designed to prevent personal injury resulting from accessibility to live parts. The interior of the
enclosure must be accessible only by the use of a tool.
The enclosure must meet IP 54 or NEMA type 4 minimum enclosure rating standards. Statement 1063
Caution
To prevent the switch assemble from overheating, there must be a minimum of 3 inches (76.19 mm)
between any other device and the top, bottom, or sides of the switch assembly.
Connecting the DC Power Clip
The DC power clip is a prewired cable that connects DC power from the power converter to the switch
module. Because the power clip uses the Pwr A connector, you cannot use the alarm connections on that
connector.
DC OK
24V , 2
.1A
Rtn Out (-)
Pwr Out (+
)
125-250V
, 1.25A M
AX
100-240V~
, 50-60Hz/
N /
L /
Cisco Catalyst
Pwr A (24VDC or 48 VD
C)
Rtn A
Pwr B (24VDC or 48 VD
C)
Rtn B
Express Setup
System
Alarm
Setup
Pwr A
Pwr B
Major Alarm
Minor Alarm
This unit migh
t have more th
an one
power cord. To
reduce the ris
k of
electric shock
disconnect th
e two
power cords b
efore servicin
g unit.
WARNING
!
202297
1
5
2
6
3
7
4
8
CO
N
SO
LE
1
2
Содержание IE 3000
Страница 34: ...1 24 Cisco IE 3000 Switch Hardware Installation Guide Chapter 1 Overview Network Configurations ...
Страница 102: ...3 8 Cisco IE 3000 Switch Hardware Installation Guide Chapter 3 Troubleshooting Finding the Switch Serial Number ...
Страница 182: ...C 12 Cisco IE 3000 Switch Hardware Installation Guide Appendix C Cable and Connectors Cable and Adapter Specifications ...