C H A P T E R

1

Preface

This preface describes the objectives, audience, organization, and conventions of this guide and describes
related documents that have additional information.

Preface, on page 1

Preface

This preface describes the objectives, audience, organization, and conventions of this guide and describes
related documents that have additional information. It contains the following sections:

Objective

This guide provides an overview and explains how to install, connect, and perform initial configuration for
the device.

Audience

This guide is intended for people who have a high level of technical ability, although they may not have
experience with Cisco software.

Conventions

This section describes the conventions used in this guide.

NOTE

: Means reader take note. Notes contain helpful suggestions or references to additional information

and material.

CAUTION

: This symbol means reader be careful. In this situation, you might do something that could result

in equipment damage or loss of data.

TIP

: Means

the following information will help you solve a problem

. The tip information might not be

troubleshooting or even an action, but could be useful information.

WARNING: IMPORTANT SAFETY INSTRUCTIONSMeans danger. You are in a situation that could
cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical
circuitry and be familiar with standard practices for preventing accidents. Use the statement number

Cisco IC3000 Industrial Compute Gateway Hardware Installation Guide

1

Содержание IC3000

Страница 1: ... Hardware Installation Guide First Published 2018 08 31 Last Modified 2019 07 16 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Страница 2: ...RSE OF DEALING USAGE OR TRADE PRACTICE IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING WITHOUT LIMITATION LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES Any Internet Protocol IP addresses and pho...

Страница 3: ...co software Conventions This section describes the conventions used in this guide NOTE Means reader take note Notes contain helpful suggestions or references to additional information and material CAUTION This symbol means reader be careful In this situation you might do something that could result in equipment damage or loss of data TIP Means the following information will help you solve a proble...

Страница 4: ...Tilanne voi aiheuttaa ruumiillisia vammoja Ennen kuin käsitt laitteistoa huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin Turvallisuusvaroitusten käännökset löytyvät laitteen mukana toimitettujen käännettyj turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien lausuntonumeroiden avulla SÄILYTÄ NÄMÄ OHJEET Varoitus IMPORTANTES INFORMA...

Страница 5: ...alquer equipamento tenha conhecimento dos perigos env no manuseio de circuitos elétricos e familiarize se com as práticas habituais de prevenção de acide Utilize o número da instrução fornecido ao final de cada aviso para localizar sua tradução nos aviso segurança traduzidos que acompanham este dispositivo GUARDE ESTAS INSTRUÇÕES Aviso INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este símbolo de aviso i...

Страница 6: ...aduzidos que acompanham dispositivo GUARDE ESTAS INSTRUÇÕES Aviso VIGTIGE SIKKERHEDSANVISNINGER Dette advarselssymbol betyder fare Du befinder dig i en situation med risiko for legemesbeskadigelse du begynder arbejde på udstyr skal du være opmærksom på de involverede risici der er ved elektriske kredsløb og du skal sætte dig ind i standardprocedurer til undgåelse af ulykker Brug erklæringsnumm eft...

Страница 7: ...Cisco IC3000 Industrial Compute Gateway Hardware Installation Guide 5 Preface Safety Warnings ...

Страница 8: ...to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system Statement 378 WARNING To avoid electric shock do not connect safety extra low voltage SELV circuits to telephone network voltage TNV circuits LAN ports contain SELV circuits and WAN ports contain TNV circuits Some LAN and WAN ports both use RJ 45 connectors Use c...

Страница 9: ...not open Statement 1073 WARNING Installation of the equipment must comply with local and national electrical codes Statement 1074 WARNING Only trained and qualified personnel should be allowed to install replace or service this equipment Statement 1030 WARNING Read the installation instructions before connecting the system to the power source Statement 1004 WARNING Ultimate disposal of this produc...

Страница 10: ...les simultaneously and to change case sensitivity and other options Adobe Reader s online help has more information about how to search PDF documents Cisco IC3000 Industrial Compute Gateway Hardware Installation Guide 8 Preface Searching Cisco Documents ...

Страница 11: ...d to meet ever increasing demand for computing resources for applications on the network edge It comes preloaded with Cisco IOx and FND software The term DIN Rail describes a metal rail of a standard type widely used for mounting circuit breakers and industrial control equipment inside equipment racks The term derives from the original specifications published by Deutsches Institut für Normung DIN...

Страница 12: ...o IC3000 SKU Figure 2 Cisco IC3000 Front Panel on page 11 shows the front panel details of the Cisco IC3000 Cisco IC3000 Industrial Compute Gateway Hardware Installation Guide 10 Product Overview General Description ...

Страница 13: ...3 Alarm Connector not supported 1 3 Console connector RJ 45 4 Grounding Point 1 4 Console connector mini USB 5 Alarm LEDs 1 5 USB connectors 6 DC Power LEDs 1 6 Management Interface 7 Gigabit Ethernet LEDs 1 7 DC power connection A 8 Management LED 1 8 DC power connection B 9 Cisco IC3000 Industrial Compute Gateway Hardware Installation Guide 11 Product Overview General Description ...

Страница 14: ...g of 5 volts and up to a maximum of 500 mA Note If you are connecting to the USB ports A connection to the USB ports can only be made in a non hazardous environment The USB port covers must be reinstalled before the IC3000 can be deployed in a hazardous environment Console Port The Cisco IC3000 can be configured through a web interface or through the console port The console port is either a RJ45 ...

Страница 15: ...sts the hardware platform features CPU Intel 4 Core 1 25Ghz 8 GB of 1333MHz DDR3 Memory Dedicated management Gigabit Ethernet port Mini USB and RJ45 Console port Two RJ45 copper ports and 2 fiber ports 12 to 48VDC Rated 9 6 to 60VDC Maximum redundant power connectors with 24 12 AWG screw cage terminals Two external USB A ports for connecting to usb to serial devices DIN Rail mount incorporated int...

Страница 16: ...ence is in the system grounding scheme used The IC3000 supports 3 basic schemes Isolated DC in neither nor terminal is tied to chassis GND Positive DC in negative terminal is tied to chassis GND Negative DC in positive terminal is tied to chassis GND Note To ensure uninterrupted operation the redundant power connections must be connected to independently separated power sources SFP Support The Cis...

Страница 17: ...arning Do not insert or remove the flash card while power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Statement 379 Caution Use a ratcheting torque flathead screwdriver to torque the power connector captive screws to 5 in lb 0 6 N m the maximum recommended torque To i...

Страница 18: ...in until it releases for it to pop out Place it in an antistatic bag to protect it from static discharge 2 After the card is installed close the guard door and fasten the captive screw using a Phillips screwdriver to keep the door in place Cisco IC3000 Industrial Compute Gateway Hardware Installation Guide 16 Product Overview Installing or Removing the SD Card Optional ...

Страница 19: ...e uncertain that suitable grounding is available Statement 1024 WARNING Only trained and qualified personnel should be allowed to install replace or service this equipment Statement 1030 WARNING Connect the unit only to DC power source that complies with the safety extra low voltage SELV requirements in IEC 60950 based safety standards Statement 1033 WARNING The covers are an integral part of the ...

Страница 20: ... device must be unrestricted Temperature surrounding the unit does not exceed 140 F 60 C which is the maximum ambient temperature of the device Note When the device is installed in an industrial enclosure the temperature within the enclosure is greater than normal room temperature outside the enclosure Cabling is away from sources of electrical noise such as radios power lines and fluorescent ligh...

Страница 21: ...d latch 2 at the bottom rear of the device to move down and snap into place Removing the Device from a DIN Rail To remove the device from a DIN rail follow these steps 1 Ensure that power is removed from the device and disconnect all cables and connectors from the front panel of the device 2 Insert a tool such as a flathead screwdriver in the slot at the bottom of the spring loaded latch 3 and use...

Страница 22: ...lug is not supplied with the device You can use either a single ring terminal or two single ring terminals WARNING This equipment needs to be grounded Use a green and yellow 16 AWG 1 5mm2 ground wire to connect the host to earth ground during normal use Statement242 WARNING This equipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably insta...

Страница 23: ...ure 5 Crimping the Ring Terminal Step 4 Slide the ground screw through the terminal Step 5 Insert the ground screw into the functional ground screw opening on the front panel Step 6 Attach the ring terminal to the chassis using the screw set aside in step 1 Use a ratcheting torque screwdriver to tighten the ground screws and ring terminal to the device front panel to 3 5 in lb 0 4 N m See item 1 i...

Страница 24: ...her end of the ground wire to a known reliable earth ground point at your site Cisco IC3000 Industrial Compute Gateway Hardware Installation Guide 22 Installing the Cisco IC3000 Industrial Compute Gateway Installing the Cisco IC3000 Ground Connection ...

Страница 25: ...he package WARNING To avoid electric shock do not connect safety extra low voltage SELV circuits to telephone network voltage TNV circuits LAN ports contain SELV circuits and WAN ports contain TNV circuits Some LAN and WAN ports both use RJ 45 connectors Use caution when connecting cables Statement 1021 Preventing Damage to the Cisco IC3000 Before installation observe these general guidelines Prop...

Страница 26: ...the mini USB connector is being used the protective cover will need to be removed first Item 1 in the following graphic shows the location of the cover Remove the cover with a Phillips screw driver and set it aside to be reinstalled after completing the configuration Cisco IC3000 Industrial Compute Gateway Hardware Installation Guide 24 Connecting the Cisco IC3000 Connecting a PC to the Cisco IC30...

Страница 27: ... you begin WARNING Before performing any of the following procedures ensure that power is removed from the DC circuit Statement 1003 WARNING This product relies on the building s installation for short circuit overcurrent protection Ensure that the protective device is rated not greater than 60 VDC minimum 5A maximum Statement 1005 WARNING A readily accessible two poled disconnect device must be i...

Страница 28: ...he device can operate with a single power source or with dual power sources When both power sources are operational the device draws power from the DC source with the higher voltage If one of the two power sources fail the other continues to power the device To connect DC power to your Cisco IC3000 follow these steps Step 1 Locate the two power connectors on the device front panel labeled DC A and...

Страница 29: ...ection See Figure 11 Inserting Wires into the Power Connector on page 27 Figure 11 Inserting Wires into the Power Connector Ensure that you cannot see any wire lead Only wire with insulation should extend from the connector Note Step 7 Use a ratcheting torque flathead screwdriver to torque the power connector captive screws above the installed wire leads to 2 in lb 0 23 N m See 1 in Figure 12 Torq...

Страница 30: ...ough 8 using the second power connector Attaching the DC Power Connectors to the Device To attach the power connectors to the front panel of the device follow these steps 1 Insert one power connector into the DC A receptacle on the device front panel and the other into the DC B receptacle 2 Use a ratcheting torque flathead screwdriver to tighten the captive screws on the sides of the power connect...

Страница 31: ...nt 397 WARNING When you connect or disconnect the power and or alarm connector with power applied an electrical arc can occur This could cause an explosion in hazardous area installations Be sure that all power is removed from the device and any other circuits Be sure that power cannot be accidentally turned on or verify that the area is nonhazardous before proceeding Statement 1058 Cisco IC3000 I...

Страница 32: ...Cisco IC3000 Industrial Compute Gateway Hardware Installation Guide 30 Connecting the Cisco IC3000 Attaching the DC Power Connectors to the Device ...

Страница 33: ...tform Services manage the system initialization This includes creating a signed image enabling Linux kernel support enabling utilities support and enabling diagnostics and troubleshooting IoT Field Network Director FND IoT Field Network Director IoT FND is a software platform that helps to enable a clear separation between communications network management and operational applications such as dist...

Страница 34: ...s 169 254 10 1 to the service bridge interface that the management port mgmt0 is attached to End users could connect a device a laptop for example directly to the management port of the device launch a browser on the laptop and access IOx local manager at https 169 254 10 1 8443 from the browser The Local Manager login page will appear Basic device configuration functions are available on the Devi...

Страница 35: ... 4 42 x 6 31 in 13 cm x 11 2 x 16 cm Dimensions H x W x D 4 75 lbs Weight 40C to 60C 0 LFM 40C to 70C 40 LFM 34C to 75C 200 LFM 500 to 5 000 feet Derate max operating temperature 1 5 C per 1000 feet 10 000 ft maximum Note This product has been safety certified up to 60C maximum ambient Operating Temperature 0 to 95 RH non condensing Humidity IP30 Ingress Protection Rating UL 60950 1 2nd edition CA...

Страница 36: ...945 Industrial EN61131 2 IEC61131 2 Railway EN50155 Smart Grid EN61850 3 IEEE 1613 Shock Vibration Maximum operating range 9 6 to 60 VDC Rated 12 to 48 VDC The DC input power supply is an SELV circuit and it can only be connected to another SELV circuit DC input voltage 0 5A 48VDC 1 0A 24VDC 2 0A 12VDC Maximum DC input current 24 Watts Power consumption Cisco IC3000 Industrial Compute Gateway Hard...