Fourth Generation Versatile Interface Processor (VIP4) Installation and Configuration Guide
OL-3673-01
VIP4 Maintenance Procedures
Figure 4
Location of CPU Memory and Packet Memory DIMMs on the VIP4
Caution
To prevent ESD damage, handle DIMMs by the card edges only. Place removed DIMMs on an antistatic
mat and store them in an antistatic bag.
Note
Use only SDRAM DIMMs from Cisco Systems. A Cisco manufacturing part number appears on each
SDRAM DIMM.
Removing SDRAM DIMMs
Use the following procedure to remove the existing DIMMs:
Step 1
Turn off the system power and remove the VIP4 from the system. (Follow the steps in the
“Removing a
VIP4” section on page 18
.)
Step 2
Place the VIP4 on an antistatic mat or pad and ensure that you are wearing an antistatic device, such as
a wrist strap.
Position the VIP4 so that the handles are away from you and the bus connectors are toward
you—opposite of the position shown in
Figure 4
.
Step 3
Locate the DIMM and position the VIP4 so that you are facing the DIMM module you want to remove.
Step 4
Open the DIMM socket tabs on the DIMM to release the DIMM from the socket. (See
Figure 5
.) The
DIMM is under tension in the socket; therefore, the DIMM might be released from the socket with
some force.
26561
CPU memory
DIMM U1
Port adapter
in slot 0
Port adapter
in slot 1
Packet
memory
DIMM U5
CPU
Bus connector