4.
Line up the module with the port.
5.
Slide the module into the port. If the module is an actuator-button
type, do not press the actuator button as you insert the module,
as this might stop the module from seating correctly inside the
port.
6.
Push gently but firmly on the outer face of the module. If the
module is correctly aligned, you will hear a click as the slide pin at
the bottom of the module snaps into place.
To remove an XCO-type SFP module from the Cisco FM4200 Fiber, do
the following steps:
CAUTION
Do not remove or insert SFP modules any more often than
absolutely necessary. Removing and inserting SFP modules
can shorten their useful life.
Do not install or remove the SFP module if a fiber-optic cable is
attached to it. This can damage the cable, the cable connector,
and the optical interfaces in the SFP module.
1.
Wear an ESD-preventive wrist or ankle strap, and follow its
instructions for use.
2.
Disconnect and remove the fiber-optic cable from the SFP
module before removing or installing the module.
3.
Insert a clean dust cover into the SFP module’s interface port.
4.
Remove the SFP module from its receptacle, using the correct
method for each module type as shown below:
• If the module is a bale-clasp type, open the bale clasp on
the module in a
downward
direction using a small flat-blade
screwdriver.
• If the module is a mylar-tab type, pull the tab gently in a
slightly
downward
direction until the module disengages
from the port. Do not twist or jerk the tab, as this can cause
the tab to disconnect from the module.
• If the module is an actuator-button type,
gently
press the
actuator button on the front of the module until the module
is released from the port.
• If the module is a slide-tab type, push the slide tab on the
bottom front of the module
inward
to disengage the module
from the port.
5.
Grasp the SFP module between your thumb and index finger, and
carefully remove the module from the port.
6.
Immediately place the removed SFP module on an anti-static
mat, or in a static shielding bag.
Hardware installation
© 2021 Cisco and/or its affiliates. All rights reserved.
Page 47 of 189