Operating and Storage Temperatures
Table 3: Battery Backup Unit—Operating and Storage Temperatures
External Ambient Temperature
Local BBU Internal Temperature
BBU State
-4 to 104°F (-20 to 40°C)
+32 to 122°F (0 to 50°C)
Charging
-40 to 122°F (-40 to 50°C)
-4 to 140°F (-20 to 60°C)
Discharging
-40 to 158°F (-40 to 70°C)
-4 to 185°F (-20 to 85°C)
Operation (Idle)
• Short-term:
+14 to 113°F (-10 to 45°C) for 3
months maximum
• Long-term:
+27 to 77°F (-3 to 25°C)
- 65% Relative Humidity
- 40 to 90% SOC
+14 to 113°F (-10 to 45°C) for 3 months
maximum
Storage and shipping
Battery Life
Table 4: Battery Backup Unit — Battery Life
Charge-Discharge Cycles
Battery Life
Product ID
500
5 years
IRMH-BATT-4AH
Installing Battery Backup Units
18
Installing Battery Backup Units
Operating and Storage Temperatures