![Cisco DPC2203C Скачать руководство пользователя страница 61](http://html.mh-extra.com/html/cisco/dpc2203c/dpc2203c_installation-and-operation-manual_65872061.webp)
Ranging Not Complete
72-4017315-01 Rev B
45
Ranging Not Complete
Description
After the cable modem finds the CMTS downstream channel and upstream
parameters, it starts the ranging and automatic adjustments stage. This stage adjusts
the timing offset and the power level for communication with the CMTS.
Note:
For more information on this process, see
Adjust Timing Offset and Power
Level
(on page 9).
The following table illustrates the status of the front-panel LED status indicators
when the
ranging not complete
condition exists.
LED
Label
Status
1
POWER
ON
2
DS
ON
3
US
BLINKING
4
ONLINE
OFF
5
LINK
ON or BLINKING
6
TEL 1
OFF
7
TEL 2
OFF
8
BATTERY
ON WHEN BATTERY IS CHARGED
BLINKING WHEN BATTERY CHARGE IS
LOW
OFF WHEN BATTERY NEEDS TO BE
REPLACED (IF OBSERVED WITH AC
POWER APPLIED TO THE MODEM)
Check and Correct
1
Using the Web browser on the PC attached to the cable modem, access the
WebWizard by entering the following IP address:
http://192.168.100.1
. The Web
browser accesses the WebWizard and the Default Page opens.
2
Select the
Signal
page and verify that the cable modem locks to the downstream
channel of the CMTS.
3
Check the upstream power level and the Signal-to-Noise ratio to verify if it is
outside of the operating range.
Содержание DPC2203C
Страница 1: ...72 4017315 01 Rev B DPC2203C VoIP Cable Modem Installation and Operation Guide ...
Страница 2: ......
Страница 10: ......
Страница 12: ......
Страница 16: ...About This Guide xvi 72 4017315 01 Rev B Document Version This is the second release of this document ...
Страница 28: ......
Страница 50: ......
Страница 52: ...Chapter 4 Troubleshooting the Installation 36 72 4017315 01 Rev B ...
Страница 72: ......
Страница 82: ......
Страница 97: ......