1-Port and 2-Port ISDN-PRI Network Module
Configuration Note

Product Numbers:
NM-1CT1, NM-1CT1-CSU, NM-2CT1, NM-2CT1-CSU, NM-1CE1-B, NM-2CE1-B,
NM-1CE1-U, NM-2CE1-U

CPANM-1CT1, CPANM-1CT1-CSU, CPANM-2CT1, CPANM-2CT1-CSU,
CPANM-1CE1-B, CPANM-2CE1-B, CPANM-1CE1-U, CPANM-2CE1-U

This document provides information about the following network modules for the Cisco 3600 series
of modular access routers:

1-port channelized T1/ISDN-PRI network module, Cisco product number NM-1CT1 or
CPANM-1CT1. (See Figure 1.) This module will also be referred to as the 1-port CT1/PRI
network module.

2-port channelized T1/ISDN-PRI network module, Cisco product number NM-2CT1 or
CPANM-2CT1. (See Figure 2.) This module will also be referred to as the 2-port CT1/PRI
network module.

1-port channelized T1/ISDN-PRI with CSU network module, Cisco product number
NM-1CT1-CSU or CPANM-1CT1-CSU. (See Figure 3.) This module will also be referred to as
the 1-port CT1/PRI-CSU network module.

2-port channelized T1/ISDN-PRI with CSU network module, Cisco product number
NM-2CT1-CSU or CPANM-2CT1-CSU. (See Figure 4.) This module will also be referred to as
the 2-port CT1/PRI-CSU network module.

1-port channelized E1/ISDN-PRI balanced (120-ohm) network module, Cisco product number
NM-1CE1B or CPANM-1CE1B. (See Figure 5.) This module will also be referred to as the 1-port
CE1/PRI-B network module.

78-3052-01

Содержание CPANM-1CE1-B

Страница 1: ...odule will also be referred to as the 1 port CT1 PRI network module 2 port channelized T1 ISDN PRI network module Cisco product number NM 2CT1 or CPANM 2CT1 See Figure 2 This module will also be referred to as the 2 port CT1 PRI network module 1 port channelized T1 ISDN PRI with CSU network module Cisco product number NM 1CT1 CSU or CPANM 1CT1 CSU See Figure 3 This module will also be referred to ...

Страница 2: ...2CE1U See Figure 6 This module will also be referred to as the 2 port CE1 PRI U network module Unless specifically identified references to PRI modules in this configuration note include all these network modules Figure 1 1 Port Channelized T1 ISDN PRI Network Module Figure 2 2 Port Channelized T1 ISDN PRI Network Module Figure 3 1 Port Channelized T1 ISDN PRI with CSU Network Module LOOPBACK CTRL...

Страница 3: ...this document for further information This document contains the following sections Safety Recommendations page 4 Required Tools and Equipment page 6 Installing PRI Network Modules in a Chassis Slot page 7 Connecting the PRI Module to the Network page 8 PRI Module Pinouts page 11 LOOPBACK EN cT1 CSU H7466 LOCAL ALARM REMOTE ALARM CARRIER DETECT RX OUT RX MON CTRLR 1 CTRLR 0 TX IN LOOPBACK LOCAL AL...

Страница 4: ...nts ensure that you have discharged all static electricity from your body before opening the chassis Before performing procedures described in this document review the next section Safety Recommendations Safety Recommendations Follow these guidelines to ensure general safety Keep the chassis area clear and dust free during and after installation Put the removed chassis cover in a safe place Keep t...

Страница 5: ...d to power and ground and can cause serious burns or weld the metal object to the terminals To see translated versions of this warning refer to the Regulatory Compliance and Safety Information document that accompanied the router Follow these guidelines when working on equipment powered by electricity Locate the emergency power OFF switch in the room in which you are working Then if an electrical ...

Страница 6: ...or external cardiac compressions then take appropriate action Preventing Electrostatic Discharge Damage Electrostatic discharge ESD can damage equipment and impair electrical circuitry It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures Always follow ESD prevention procedures when removing and replacing cards Ensure that the ro...

Страница 7: ...erface cables including telephone cables from the rear panel The following warning applies to routers that use a DC power supply Warning Before performing any of the following procedures ensure that power is removed from the DC circuit To ensure that all power is OFF locate the circuit breaker on the panel board that services the DC circuit switch the circuit breaker to the OFF position and tape t...

Страница 8: ...panied the router Blank Network Module Panels If the router is configured with fewer than four network modules make sure that blank panels fill the open chassis slots to provide proper airflow See Figure 7 Figure 7 Blank Network Module Panel Connecting the PRI Module to the Network This section explains how to connect a PRI network module to a WAN CT1 PRI Modules To connect a CT1 PRI module use a ...

Страница 9: ...le use the appropriate cable to connect the CE1 PRI B port to an E1 CSU See Figure 10 Figure 11 and Figure 12 showing DB 15 Twinax and RJ 45 CSUs respectively Figure 10 Connecting a 120 Ohm CE1 PRI B Module to an E1 CSU DB 15 to DB 15 Connectors H7469 RJ 48C jack CT1 PRI CSU port RJ 48C LOOPBACK EN cT1 CSU LOCAL ALARM REMOTE ALARM CARRIER DETECT RX OUT RX MON CTRLR 0 TX IN LOOPBACK CTRLR 0 EN cE1 ...

Страница 10: ...odule use the appropriate cable to connect the CE1 PRI U port to an E1 CSU See Figure 13 The illustration shows a CSU with BNC connectors LOOPBACK CTRLR 0 EN cE1 B PRI H7473 LOCAL ALARM REMOTE ALARM CARRIER DETECT CE1 PRI port DB 15 Twinax connectors E1 CSU E1 cable for 75 ohm balanced connections with twinax connectors at the network end LOOPBACK CTRLR 0 EN cE1 B PRI H7472 LOCAL ALARM REMOTE ALAR...

Страница 11: ... modem cables are used for back to back operation and testing T1 interface cables have two male DB 15 connectors one at each end to connect the CT1 PRI module with the external T1 CSU Figure 14 shows the cable and connectors Table 1 lists the pinout for the straight through T1 cable and Table 2 lists the pinout for the null modem T1 cable Figure 14 T1 Interface Cable LOOPBACK CTRLR 0 EN cE1 U PRI ...

Страница 12: ...1 cables have a DB 15 connector at the router end Cables for CE1 PRI B modules have either DB 15 Twinax or RJ 45 connectors at the network end See Figure 15 Figure 16 and Figure 17 The cable for CE1 PRI U modules has a BNC connector at the network end See Figure 18 DB 15 Connector DB 15 Connector Signal Pin Pin Signal Transmit Tip 1 1 Transmit Tip Transmit Ring 9 9 Transmit Ring Receive Tip 3 3 Re...

Страница 13: ...le for 120 Ohm Balanced Connections DB 15 Connector Figure 16 E1 Interface Cable for 120 Ohm Balanced Connections Twinax Connectors Figure 17 E1 Interface Cable for 120 Ohm Balanced Connections RJ 45 Connector Figure 18 E1 Interface Cable for 75 Ohm Unbalanced Connections BNC Connectors H2476 H2424 H2422 H2421 ...

Страница 14: ...CE1 PRI Network Module Cable Pinouts CE1 PRI End Network End DB 15 BNC DB 15 Twinax RJ 45 Pin Signal1 Signal Pin Signal Pin Signal Pin Signal 9 Tx Tip Tx Tip 1 Tx Tip Tx 1 Tx Tip 4 Tx Tip 2 Tx Ring Tx Shield 9 Tx Ring Tx 2 Tx Ring 5 Tx Ring 10 Tx Shield 2 Tx Shield Shiel d Tx Shield 6 Tx Shield 8 Rx Tip Rx Tip 3 Rx Tip Rx 1 Rx Tip 1 Rx Tip 15 Rx Ring Rx Shield 11 Rx Ring Rx 2 Rx Ring 2 Rx Ring 7 R...

Страница 15: ...ure 21 and Figure 22 show CT1 PRI CSU module LEDs Figure 21 1 Port CT1 PRI CSU Network Module LEDs LOOPBACK CTRLR 0 EN cT1 PRI H7462 LOCAL ALARM REMOTE ALARM CARRIER DETECT CT1 PRI LEDs Enable LED LOOPBACK CTRLR 0 EN cT1 PRI H7463 LOCAL ALARM REMOTE ALARM CARRIER DETECT LOOPBACK CTRLR 1 LOCAL ALARM REMOTE ALARM CARRIER DETECT CT1 PRI LEDs Enable LED CT1 PRI LEDs LOOPBACK EN cT1 CSU H7467 LOCAL ALA...

Страница 16: ...rk Module LEDs Figure 24 2 Port CE1 PRI Network Module LEDs LOOPBACK EN cT1 CSU H7466 LOCAL ALARM REMOTE ALARM CARRIER DETECT RX OUT RX MON CTRLR 1 CTRLR 0 TX IN LOOPBACK LOCAL ALARM REMOTE ALARM CARRIER DETECT CT1 PRI CSU LEDs CT1 PRI CSU LEDs LOOPBACK CTRLR 0 EN cE1 PRI H7262 LOCAL ALARM REMOTE ALARM CARRIER DETECT CE1 PRI LEDs Enable LED LOOPBACK CTRLR 0 EN cE1 PRI H7263 LOCAL ALARM REMOTE ALAR...

Страница 17: ...AN cables from the router to keep it from trying to run the AutoInstall process The router tries to run AutoInstall whenever you power it ON if there is a WAN connection on both ends and the router does not have a valid configuration file stored in nonvolatile random access memory NVRAM for instance when you add a new interface It can take several minutes for the router to determine that AutoInsta...

Страница 18: ...ter config ip routing Router config appletalk routing Router config ipx routing For complete information about global configuration commands refer to the Cisco IOS configuration guides and command references Step 6 Enter the controller t1 command to select the CT1 PRI interface to configure For example to configure a T1 interface in slot 1 and unit 0 enter the following command Router config cont ...

Страница 19: ...he interface characteristics Refer to the Cisco IOS configuration guides and command references for more information Step 14 If your router has more than one CT1 PRI interface enter the exit command to return to the Router config prompt Repeat Step 6 through Step 13 of this procedure to configure the next CT1 PRI interface Step 15 By default the router allocates 25 percent of dynamic random access...

Страница 20: ...procedure Step 1 Connect a console to the router If you need instructions for connecting a console refer to the installation chapter of your router installation and configuration guide Power up the router Step 2 If the current configuration is no longer valid after about a minute you see the following prompt Would you like to enter the initial dialog yes Answer no You now enter the normal operatin...

Страница 21: ... 0 changed state to up Router config controller Router config controller Step 9 After you define E1 channel groups you can configure each channel group as a virtual serial interface Specify the CE1 PRI interface unit number and channel group to modify as in the following example Router config controller int serial 1 0 0 Step 10 Assign an IP address and subnet mask to the interface using the ip add...

Страница 22: ...py running config startup config at the enable prompt Router copy running config startup config Building configuration OK Router The router is now configured to boot in the new configuration Obtaining Service and Support For service and support for a product purchased from a reseller contact the reseller Resellers offer a wide variety of Cisco service and support programs which are described in th...

Страница 23: ...cs rep cisco com This document is to be used in conjunction with your router installation and configuration guide and the Regulatory Compliance and Safety Information document for your router AtmDirector AutoConnect AutoRoute AXIS BPX Catalyst CD PAC CiscoAdvantage CiscoFusion Cisco IOS the Cisco IOS logo CiscoLink CiscoPro the CiscoPro logo CiscoRemote the CiscoRemote logo CiscoSecure Cisco Syste...