Installing the Cisco Content Engine 510 and 565
78-14731-02
Installing a Content Engine 510 or 565 Unit
Step 4
Insert the tab (labeled 1 in
Figure 9
) on the rear of the slide rail assembly through the center hole between
the two clip nuts or cage nuts on the rear flange.
Figure 9
Attaching the Slide Rails to the Rack
Step 5
Align the slide rail assembly to the front flange on the rack and insert and tighten two M6 screws to
secure the slide rail to the front flange. (See
Figure 9
.)
Note
If it is necessary to adjust the length of the slide rail, loosen the adjustment screw (labeled 2 in
Figure 9
) in on the rear of the slide rail and then adjust the length of the slide rail and tighten the
adjustment screw.
Repeat
Step 4
and
Step 5
to install the other slide rail assembly.
Step 6
Align and insert the inner slide rails into the slide rail assemblies until they lock into place.
Step 7
Slide the Content Engine into the rack until the Content Engine locks into place.