1-3

Cisco Video Surveillance 5010/5011 Indoor Fixed HD IP Dome Camera User Guide

OL-22669-02

Chapter 1      Introduction

Product Overview

Figure 1-2

Camera Connections and Features (Top View)

1

Reset Button:

 Reboots the camera or restores the camera’s factory default settings. This 

button is recessed. Using a small tool, such as a paper clip, press and release the reset button 
once to reboot the camera. Press and hold the reset button for 10 seconds to restore the camera 
to the factory default settings.

2

Micro SD Card Slot:

 Saves a snapshot image to a micro SD card based on alarm activity.

3

Power LED: 

Glows solid green to indicate that the camera has power and flashes green during 

the boot cycle. The LED can be disabled through the user interface. If this LED glows red 
(solid or flashing), contact Cisco support for assistance.

4

Lens Mount: 

Fits a standard CS-mount lens. Use a megapixel lens with the 5010/5011 

cameras. A standard definition lens installed on a megapixel camera will limit the resolution 
of the camera and create poor image quality.

5

Auto Iris Lens Connector: 

Controls the auto iris lens. Insert the 4-pin connector from the DC 

drive auto iris lens into this connector.

6

NTSC/PAL Button:

 Toggles the service connector between NTSC and PAL formats. The 

default setting is NTSC.

7

Service Port:

 Outputs analog video. Use this port at the installation site to set up the field of 

view and to focus the camera. When a service cable is connected to the camera, video to the 
IP stream is disabled.

8

Auto Back Focus Button:

 Sets the auto back focus mechanism. Press the button once to 

center the auto back focus mechanism and to fully open the iris. Press and hold the button for 
three seconds to start the auto back focus mechanism and focus the camera.

9

Ethernet Activity/Link LED: 

Flashes green to indicate that data is being transmitted or 

received by the camera. Glows solid amber to indicate that a live network connection is 
established and then turns off after one minute of operation.

1

2

7

3

8

9

4

5

6

278771

Содержание CIVS-IPC-5010

Страница 1: ...eras accept a wide range of megapixel varifocal CS mount lenses The cameras also include built in Power over Ethernet PoE which supplies power to the camera through the network If PoE is not available the camera is prewired for 24 VAC Models Getting Started Before installing your network camera thoroughly familiarize yourself with the information in this section of the manual Note Do not use a net...

Страница 2: ... ring and bubble 1 Dome liner 1 4 pin connector 1 2 pin connector 1 Quick Start Guide 1 Relay and Alarm Connections One relay that can be used to control an external circuit and one alarm for physical input into the system 2 Accessory Port For use with compatible accessories 3 RJ 45 Network Port Connects the camera to the IP network Also supplies power to the camera through the network using PoE I...

Страница 3: ... cameras A standard definition lens installed on a megapixel camera will limit the resolution of the camera and create poor image quality 5 Auto Iris Lens Connector Controls the auto iris lens Insert the 4 pin connector from the DC drive auto iris lens into this connector 6 NTSC PAL Button Toggles the service connector between NTSC and PAL formats The default setting is NTSC 7 Service Port Outputs...

Страница 4: ... Guide OL 22669 02 Chapter 1 Introduction Product Overview Product Label The product label lists the model number date code serial number and Media Access Control MAC address This information might be required for setup The product label is located on the side of the back box ...

Отзывы: