background image

 

A-6

Cisco 827 and SOHO 77 Routers Hardware Installation Guide

78-6854-03

Appendix A      Specifications and Cables

Cabling Specifications

Maximum Cable Distances

Table A-9

 provides the maximum distances of Ethernet and telephone cables that you can use to connect 

equipment to the router.

Table A-8

Ethernet Cable Specifications

Type

Category

Shielding

10BASE-T

Category 3 or 5

Shielded twisted-pair (STP)

10BASE-T

Unshielded twisted-pair (UTP)

Table A-9

Maximum Cable Distances

Cable

Maximum Distance

Ethernet cables

328 ft (100 m)

Telephone cable

500 ft (152 m)

Содержание CISCO827

Страница 1: ...de desktop power supply Cisco 827 4V router 1 5 lb 0 68 kg Cisco 827H router 1 48 lb 0 67 kg Cisco 827 router 1 48 lb 0 67 kg Environmental Operating Ranges Nonoperating temperature 4 to 149 F 20 to 65 C Nonoperating humidity 5 to 95 relative humidity Nonoperating altitude 0 to 15 000 ft 4570 m Operating temperature 32 to 104 F 0 to 40 C Operating humidity 10 to 85 relative humidity Operating alti...

Страница 2: ... for connecting a terminal or PC See Table A 3 Telephone See Table A 4 ADSL See Table A 5 Power See Table A 6 and Table A 7 Table A 2 shows the Ethernet connector pinouts for the Cisco 827 4V Cisco 827 Cisco 827H SOHO 77 and SOHO 77H routers Table A 3 shows the Ethernet connector pinouts for the Cisco 827 4V Cisco 827 Cisco 827H SOHO 77 and SOHO 77H routers Telephone Port Power Cisco 827 4V Voltag...

Страница 3: ... SOHO 77 Routers Hardware Installation Guide 78 6854 03 Appendix A Specifications and Cables Port Connector Pinouts Table A 3 Console Connector Pinouts RJ 45 Pin Function 1 RTS 2 DTR 3 TXD 4 GND 5 GND 6 RXD 7 DSR 8 CTS ...

Страница 4: ...lows 9600 baud Eight data bits No parity One stop bit Table A 4 shows telephone connector pinouts for the Cisco 827 4V router Table A 5 shows ADSL connector pinouts for the Cisco 827 4V Cisco 827 Cisco 827H SOHO 77 and SOHO 77H routers Table A 4 Cisco 827 4V Router Telephone Connector Pinouts RJ 11 Pin Function 1 Unused 2 Tip 3 Ring 4 Unused Table A 5 ADSL Connector Pinouts RJ 11 Pin Function 1 Lo...

Страница 5: ...t cables which you might need to provide Straight through cables Crossover cables This section also provides information on Ethernet and telephone cable distance limitations Telephone cable connects a device to a telephone port Ethernet Cable Specifications Table A 8 lists the specifications for straight through and crossover Ethernet cables Table A 6 Cisco 827 Cisco 827 4V and SOHO 77 Power Conne...

Страница 6: ...s the maximum distances of Ethernet and telephone cables that you can use to connect equipment to the router Table A 8 Ethernet Cable Specifications Type Category Shielding 10BASE T Category 3 or 5 Shielded twisted pair STP 10BASE T Unshielded twisted pair UTP Table A 9 Maximum Cable Distances Cable Maximum Distance Ethernet cables 328 ft 100 m Telephone cable 500 ft 152 m ...

Отзывы: