or a module and a suspected highly attenuated network. If the link LED does not light up, try removing the
network cable plug and reinserting it firmly into the module socket. It is possible that dirt or skin oils have
accumulated on the plug faceplate (around the optical-fiber openings), generating significant attenuation and
reducing the optical power levels below threshold levels so that a link cannot be established.
Use extreme care when removing or installing connectors so that you do not damage the connector housing
or scratch the end-face surface of the fiber. Always install protective covers on unused or disconnected
components to prevent contamination. Always clean fiber connectors before installing them.
Caution
LC Connector
The LC fiber optic connector is a small form-factor fiber-optic connector that provides high-density fiber
connectivity. The LC connector can be used with either MMF cable or SMF cable. The LC connector uses a
latching clip mechanism that is similar to the one used on the RJ-45 copper connector.
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams
or view directly with optical instruments. Statement 1051
Warning
Make sure that the optical connectors are clean before making the connections. Contaminated connectors
can damage the fiber and cause data errors.
Note
Figure 17: LC Fiber-Optic Connector
Catalyst 6800 Ethernet Module Installation Guide
53
Pluggable Transceivers, Module Connectors
LC Connector