Catalyst 3550 Multilayer Switch Hardware Installation Guide
78-11358-03
Chapter 2 Installing and Starting the Switch
Connecting a PC or Terminal to the Console Port
Follow these steps to connect the PC or terminal to the switch:
Step 1
Configure the baud rate and character format of the PC or terminal to match these
console port default characteristics:
•
9600 baud
•
8 data bits
•
1 stop bit
•
No parity
After you have gained access to the switch, you can change the console baud rate
through the Administration > Console Baud Rate menu in the Cluster
Management Suite (CMS).
Step 2
Using the supplied RJ-45-to-DB-9 adapter cable, insert the RJ-45 connector into
the console port, as shown in
Step 3
Attach the DB-9 female DTE adapter of the RJ-45-to-DB-9 adapter cable to a PC,
or attach an appropriate adapter to the terminal.
Step 4
Start the terminal-emulation program if you are using a PC or terminal.
Figure 2-39 Connecting to the Catalyst 3550-12T and 3550-12G Console Port