Cisco Catalyst Switch Module 3110G, 
3110X, and 3012 for IBM BladeCenter 
Hardware Installation Guide

April 2008

Text Part Number: OL-12192-01

Содержание Catalyst 3012

Страница 1: ... Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 Cisco Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Hardware Installation Guide April 2008 Text Part Number OL 12192 01 ...

Страница 2: ... be required to correct any interference to radio or television communications at your own expense You can determine whether your equipment is causing interference by turning it off If the interference stops it was probably caused by the Cisco equipment or one of its peripheral devices If the equipment causes interference to radio or television reception try to correct the interference by using on...

Страница 3: ...t 1 4 Port Numbering 1 4 Internal 100BASE T Ethernet Management Port 1 4 Switch Module LEDs 1 5 StackWise Plus Ports 1 9 Console Port 1 9 Management Options 1 9 Network Configurations 1 10 C H A P T E R 2 Switch Module Installation 2 1 Preparing for Installation 2 1 Safety Warnings 2 1 Installation Guidelines 2 3 Box Contents 2 3 Installing the Switch Module 2 4 After Installing the Switch Module ...

Страница 4: ...erformance 3 4 Resetting the Switch Module 3 4 Using the Mode Button to Reset the Switch Module 3 5 How to Replace a Failed Stack Member 3 5 A P P E N D I X A Technical Specifications A 1 A P P E N D I X B Connector and Cable Specifications B 1 Connector Specifications B 1 10 100 1000 Ports B 1 10 Gigabit Ethernet Module Interface B 2 Console Port B 2 Cable and Adapter Specifications B 2 10 Gigabi...

Страница 5: ...e switch module getting started guide the software configuration guide the command reference and the system message guide on Cisco com For information about the standard Cisco IOS Release 12 1 or 12 2 commands see the Cisco IOS documentation set from the Cisco com home page at Technical Support and Documentation Documentation On the Cisco Documentation home page select Release 12 1 or 12 2 from th...

Страница 6: ... descriptions of the system messages specifically created or modified for the switch module Cisco Software Activation Document for IBM BladeCenter This document describes the supported feature sets software licenses and information about using software activation in mixed software switch stacks Cisco Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Getting Started Guide This guide p...

Страница 7: ... not support stacking Unless otherwise noted the term switch module refers to a standalone switch module and to a switch stack Note This product is not intended to be connected directly or indirectly by any means whatsoever to interfaces of public telecommunications networks This chapter provides a functional overview of the switch modules and covers these topics Switch Modules page 1 1 Hardware F...

Страница 8: ...nk ports 1 internal 100BASE T Ethernet management port 2 StackWise Plus ports CatalystSwitch Module 3012 WS CBS3012 IBM WS CBS3012 IBM I 4 external 10 100 1000BASE T Ethernet ports 14 internal 1000BASE X Ethernet downlink ports 1 internal 100BASE T Ethernet management port Table 1 1 Catalyst Switch Module 3110G 3110X and 3012 continued Switch Model Cisco Part Number IBM Part Number Description 1 C...

Страница 9: ...d RJ 45 connectors with Ethernet pinouts The maximum cable length is 328 feet 100 meters The 100BASE TX and 1000BASE T traffic requires Category 5 Category 5e or Category 6 unshielded twisted pair UTP cable The 10BASE T traffic can use Category 3 or Category 4 UTP cable For information about the 10 100 1000 Ethernet port connections and specifications see the Connecting Devices to the Ethernet Por...

Страница 10: ...ee Appendix B Connector and Cable Specifications Port Numbering Table 1 2 describes the switch module port numbering Internal 100BASE T Ethernet Management Port The internal Ethernet management port Fa0 is used only for switch module management traffic not for data traffic It is connected to the IBM advanced Management Module aMM through the blade enclosure backplane connector Traffic to and from ...

Страница 11: ...le LEDs and Mode Button 1 Stack member LED Catalyst Switch Module 3110G 8 Stack member LED 2 Mode button 9 Mode button 3 Fault stack mode LED Catalyst Switch Module 3110G Fault LED Catalyst Switch Module 3012 10 Fault stack mode LED 4 System power LED 11 System power LED 5 Stack master LED Catalyst Switch Module 3110G 12 Stack master LED 6 Port link LED 13 X2 port status LEDs 7 Port activity LED L...

Страница 12: ...he system is receiving power and is functioning properly Table 1 3 lists the LED colors and their meanings Stack Master LED The stack master LED shows the stack master status Table 1 4 lists the LED colors and their meanings only Catalyst Switch Module 3110G and 3110X Table 1 3 System LED Color System Status Off Switch module is not powered on Green Switch module is operating normally Amber Switch...

Страница 13: ...e 3012 Stack Member LED The stack member LED is active when the switch module is stacked and you select by using the Mode button The stack member LED blinks the number of times equal to the switch stack membership number Table 1 7 lists the LED colors and their meanings only Catalyst Switch Module 3110G and 3110X Table 1 5 Fault Stack Mode LED Color Fault Mode Description Stack Mode Description Of...

Страница 14: ... LED colors and their meanings Table 1 8 Catalyst Switch Module 3110G and 3012 Port LEDs Color Activity LED Description Link Status LED Description Off No activity No link or port was administratively shut down Green Link present or the port might be blocked by Spanning Tree Protocol STP and is not forwarding data Blinking green Activity Port is sending or receiving data Table 1 9 Catalyst Switch ...

Страница 15: ... connect the switch module to a host For more information about the console port see the switch module getting started guide the software configuration guide and the command reference on Cisco com Management Options The switch module offers several management options Cisco IOS CLI The switch module command line interface CLI is based on Cisco IOS software and is enhanced to support desktop switchi...

Страница 16: ... Catalyst 4506 Through a GUI users can configure and manage standalone switch modules and switch stacks Cisco Network Assistant is available at no cost and can be downloaded from this URL http www cisco com go cna_doc For information on starting the Network Assistant application see the Getting Started with Cisco Network Assistant guide on Cisco com SNMP network management You can manage switch mo...

Страница 17: ...ers these topics Safety Warnings page 2 1 Installation Guidelines page 2 3 Box Contents page 2 3 Safety Warnings This section includes the basic installation caution and warning statements Translations of the warning statements appear in the Regulatory Compliance and Safety Information for the Cisco Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter that shipped with the switch module...

Страница 18: ... Class 1 laser product Statement 1008 Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security Statement 1017 Warning Ultimate disposal of this product should be handled according to all national laws and regulations Statement 1040 Warning For connections outside...

Страница 19: ...nce to the switch module front panel is such that Front panel indicators can be easily read Access to ports is sufficient for unrestricted cabling The X2 10GB CX4 transceiver module minimum bend radius and connector length is met See the X2 transceiver module documentation for more information Confirm that cabling is away from sources of electrical noise such as radios power lines and fluorescent ...

Страница 20: ...he switch module Figure 2 1 Note Figure 2 1 shows the IBM BC H blade enclosure as an example Your blade enclosure might look different Figure 2 1 Blade Enclosure Rear Panel View Step 3 Remove the filler module from the selected bay Store the filler module for future use Step 4 If you have not already done so touch the static protective package that contains the switch module to any unpainted metal...

Страница 21: ...tion about the switch module LEDs Step 10 Replace the acoustic attenuation module if applicable To remove the switch module reverse the installation procedure Place either another switch module or a filler module in the blade enclosure bay within 1 minute of removal After Installing the Switch Module After the switch module is installed you might need to Configure the switch module with the initia...

Страница 22: ...members We recommend that you assign the highest priority value to the switch module that you prefer to be the stack master This ensures that the switch module is re elected as stack master if a re election occurs As you add new switch modules to the stack they automatically become stack members When you connect the StackWise Plus cables and create a stack only the status of the stack master Fa0 i...

Страница 23: ...he other end of the cable into the connector of the other switch module Always use a Cisco approved StackWise Plus cable to connect the switch modules Caution The new stack member switch module restarts when you connect the StackWise Plus cables Step 5 Configure the member switch modules through the master switch module by using the CLI through the console port of any stack member To remove the St...

Страница 24: ...apter 2 Switch Module Installation Creating Switch Stacks Switch Stack Cabling Examples Figure 2 4 is an example of a recommended configuration in which two switch modules create a switch stack in a single blade enclosure Figure 2 4 Stacking Switch Modules in a Single Blade Enclosure to Create One Stack 203294 ...

Страница 25: ...uide OL 12192 01 Chapter 2 Switch Module Installation Creating Switch Stacks Figure 2 5 is an example of a recommended configuration in which eight switch modules create a switch stack in eight blade enclosures Figure 2 5 Stacking Switch Modules in Blade Enclosures to Create One Stack 203295 ...

Страница 26: ...h Module Installation Creating Switch Stacks Figure 2 6 shows an example of a recommended configuration in which eight switch modules create two separate switch stacks in eight blade enclosures This configuration provides redundant connections Figure 2 6 Stacking Switch Modules in Blade Enclosures to Create Two Stacks 203296 ...

Страница 27: ...odule observe these general precautions Do not remove the module slot cover from the 10 Gigabit Ethernet slot until you are ready to install an X2 transceiver Either a module or the module slot cover must be installed in the slot at all times Do not remove the dust plugs from the fiber optic X2 transceiver modules or the rubber caps from the fiber optic cable until you are ready to connect the cab...

Страница 28: ...7 Installing an X2 Transceiver Module Removing a Module To remove an X2 transceiver module follow these steps Step 1 Attach an ESD preventive wrist strap to your wrist and to a bare metal surface Step 2 Disconnect the cables from the module For fiber optic modules install the optical bore dust plugs Step 3 Carefully pull on the X2 module sleeve to disengage it from the slot Grasp the edges of the ...

Страница 29: ...efault on the switch module With auto MDIX enabled the switch module detects the required cable type for copper Ethernet connections and configures the interface accordingly Therefore you can use either a crossover or a straight through cable for connections to a switch module 10 100 1000 Ethernet port regardless of the type of device on the other end of the connection See the switch module softwa...

Страница 30: ...2 14 Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Hardware Installation Guide OL 12192 01 Chapter 2 Switch Module Installation Where to Go Next ...

Страница 31: ...he documentation that came with your SNMP application for details Verify Switch Module POST Results As the switch module powers on it begins the power on self test POST a series of tests that runs automatically to ensure that the switch module functions properly It might take several minutes for the switch module to complete POST When POST completes successfully the System LED remains green The ot...

Страница 32: ...onnection For Ethernet use Category 3 copper cable for 10 Mb s UTP connections Use Category 5 Category 5e or Category 6 UTP for 10 100 or 10 100 1000 Mb s connections For fiber optic connectors verify that you have the correct cable for the distance and port type Make sure that the connected device ports both match and use the same type encoding optical frequency and fiber type For more informatio...

Страница 33: ...erfaces privileged EXEC command to verify the port or interface error disabled disabled or shutdown status on both sides of the connection If needed re enable the port or the interface Ping End Device Test the end device by pinging from the directly connected switch module first and then work your way back port by port interface by interface trunk by trunk until you find the source of the connecti...

Страница 34: ...t the speed and duplex parameters for the ports on both ends of the connection If a remote device does not autonegotiate configure the duplex settings on the two ports to match The speed parameter can adjust itself even if the connected port does not autonegotiate Autonegotiation and Network Interface Cards Problems sometimes occur between the switch module and third party network interface cards ...

Страница 35: ...ures described in the switch module getting started guide on Cisco com For switch stacks pressing and holding the Mode button on a member switch module causes the stack to reboot It does not remove the configuration from any member switch How to Replace a Failed Stack Member If you need to replace a failed stack member you can hot swap or replace the switch module by following this procedure only ...

Страница 36: ...3 6 Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Hardware Installation Guide OL 12192 01 Chapter 3 Troubleshooting How to Replace a Failed Stack Member ...

Страница 37: ...onmental Ranges Operating temperature 32 to 131 F 0 to 55 C Storage temperature 13 to 158 F 25 to 70 C Relative humidity 10 to 85 noncondensing Operating altitude Up to 10 000 ft 3049 m Storage altitude Up to 15 000 ft 4573 m Physical Specifications Weight 2 1 lb 0 95 kg Physical Specifications Dimensions H x D x W 1 22 x 4 65 x 10 79 in 3 1 x 11 8 x 27 4 cm Table A 2 Power Specifications Power Sp...

Страница 38: ...A 2 Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Hardware Installation Guide OL 12192 01 Appendix A Technical Specifications ...

Страница 39: ...ctor Specifications section on page B 1 Cable and Adapter Specifications section on page B 2 Connector Specifications These sections describe the connectors used with the switch modules 10 100 1000 Ports page B 1 10 Gigabit Ethernet Module Interface page B 2 Console Port page B 2 10 100 1000 Ports The 10 100 1000 Ethernet ports on switch modules use standard RJ 45 connectors and Ethernet pinouts F...

Страница 40: ...gabit Ethernet Optical Module SC Connector Figure B 3 10 Gigabit Ethernet Infiniband 4x Connector Console Port The console port uses a USB connector The supplied USB to DB 9 adapter cable is used to connect the console port of the switch module to a PC Cable and Adapter Specifications These sections describe the cables and adapters used with the switch module 10 Gigabit Ethernet X2 Transceiver Mod...

Страница 41: ...odal Bandwidth MHz km Maximum Cabling Distance X2 10GB SR 850 MMF 62 5 62 5 50 0 50 0 50 0 160 200 400 500 2000 85 feet 26 m 108 feet 33 m 217 feet 66 m 269 feet 82 m 984 feet 300 m X2 10GB LX4 1310 MMF1 1 Mode conditioning patch cord is recommended for MMF applications 62 5 50 0 50 0 500 400 500 984 feet 300 m 787 feet 240 m 984 feet 300 m X2 10GB CX4 InfiniBand copper 49 feet 15 m Table B 2 X2 T...

Страница 42: ...dapter Specifications Four Twisted Pair Cable Pinouts Figure B 4 and Figure B 5 show the schematics of four twisted pair cables Figure B 4 Four Twisted Pair Straight Through Cable Schematic Figure B 5 Four Twisted Pair Crossover Cable Schematic 1 TPO 2 TPO 3 TP1 6 TP1 1 TP1 Switch Router or PC 2 TP1 3 TPO 6 TPO 4 TP2 5 TP2 7 TP3 8 TP3 4 TP3 5 TP3 7 TP2 8 TP2 65272 ...

Страница 43: ...ematic Identifying a Crossover Cable To identify a crossover cable compare the two modular ends of the cable Hold the cable ends side by side with the tab at the back The wire connected to the pin on the outside of the left plug should be the same color as the wire connected to the pin on the outside of the right plug See Figure B 8 Figure B 8 Identifying a Crossover Cable Switch 3 TD 6 TD 1 RD 2 ...

Страница 44: ...B 6 Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Hardware Installation Guide OL 12192 01 Appendix B Connector and Cable Specifications Cable and Adapter Specifications ...

Страница 45: ...inout B 4 identifying B 5 two twisted pair pinout B 5 recommended 2 13 StackWise Plus part numbers 1 9 straight through four twisted pair pinout B 4 two twisted pair pinout B 5 X2 transceiver module B 3 Cisco IOS command line interface 1 9 Cisco IP Phones connecting to 2 13 Cisco Network Assistant 1 10 CiscoView 1 10 Class 1 laser warning 2 2 CLI 1 9 code compliance warning 2 2 command line interf...

Страница 46: ...lt stack mode 1 7 front panel 1 5 to 1 9 master 1 6 port 1 8 POST results 3 1 stack member 1 7 system power 1 6 troubleshooting with 3 1 lightning activity warning 2 2 link status troubleshooting 3 2 local and national electrical codes compliance 2 2 M mode button 1 5 N noise electrical 2 3 O outside connections warning 2 2 P pinouts 10 100 1000 ports B 1 adapters B 5 crossover cables four twisted...

Страница 47: ...cribed 1 1 1 2 system power LED 1 6 T technical specifications A 1 Telnet and accessing the CLI 1 9 temperature operating A 1 troubleshooting bad or damaged cable 3 2 connection problems 3 2 diagnosing problems 3 1 Ethernet and fiber cables 3 2 link status 3 2 ping end device 3 3 port and interface settings 3 3 POST 3 1 spanning tree loops 3 3 speed duplex and autonegotiation 3 4 switch performanc...

Страница 48: ...Index IN 4 Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Hardware Installation Guide OL 12192 01 ...