33-13
Catalyst 2928 Switch Software Configuration Guide
OL-23389-01
Chapter 33 Troubleshooting
Monitoring SFP Module Status
If the module is identified as a Cisco SFP module, but the system is unable to read vendor-data
information to verify its accuracy, an SFP module error message is generated. In this case, you should
remove and re-insert the SFP module. If it continues to fail, the SFP module might be defective.
Monitoring SFP Module Status
You can check the physical or operational status of an SFP module by using the
show interfaces
transceiver
privileged EXEC command. This command shows the operational status, such as the
temperature and the current for an SFP module on a specific interface and the alarm status. You can also
use the command to check the speed and the duplex settings on an SFP module. For more information,
see the
show interfaces transceiver
command in the command reference
for this release.
Using Ping
These sections contain this information:
•
Understanding Ping, page 33-13
•
Understanding Ping
The switch supports IP ping, which you can use to test connectivity to remote hosts. Ping sends an echo
request packet to an address and waits for a reply. Ping returns one of these responses:
•
Normal response—The normal response (
hostname
is alive) occurs in 1 to 10 seconds, depending
on network traffic.
•
Destination does not respond—If the host does not respond, a
no-answer
message is returned.
•
Unknown host—If the host does not exist, an
unknown host
message is returned.
•
Destination unreachable—If the default gateway cannot reach the specified network, a
destination-unreachable
message is returned.
•
Network or host unreachable—If there is no entry in the route table for the host or network, a
network or host unreachable
message is returned.
Executing Ping
Beginning in privileged EXEC mode, use this command to ping another device on the network from the
switch:
Command
Purpose
ping ip
host
|
address
Ping a remote host through IP or by supplying the hostname or
network address.
Содержание Catalyst 2928
Страница 28: ...Contents xxviii Catalyst 2928 Switch Software Configuration Guide OL 23389 01 ...
Страница 32: ...xxx Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Preface ...
Страница 496: ...26 14 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Chapter 26 Configuring SPAN Displaying SPAN Status ...
Страница 534: ...29 18 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Chapter 29 Configuring SNMP Displaying SNMP Status ...
Страница 700: ...Index IN 36 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 ...