Catalyst 2360 Switch Hardware Installation Guide
OL-22150-02
Chapter 2 Switch Installation
Connecting to SFP and SFP+ Modules
Before connecting to the SFP module, be sure that you understand the port and cabling stipulations in
the
“Installation Guidelines” section on page 2-3
and in the
“SFP and SFP+ Module Slots” section on
Appendix B, “Connector and Cable Specifications”
for information about the LC
connector on the SFP module.
Step 1
Remove the rubber plugs from the module port and fiber-optic cable, and store them for future use.
Step 2
Insert one end of the fiber-optic cable into the SFP or SFP+ module port (
).
Figure 2-5
Connecting to a Fiber-Optic SFP Module Port
Step 3
Insert the other cable end into a fiber-optic receptacle on a target device.
Step 4
Observe the port status LED.
The LED turns green when the switch and the target device have an established link.
The LED turns amber while the STP discovers the network topology and searches for loops. This process
takes about 30 seconds, and then the port LED turns green.
If the LED is off, the target device might not be turned on, there might be a cable problem, or there might
be problem with the adapter installed in the target device. See
for
solutions to cabling problems.
Step 5
If necessary, reconfigure and restart the switch or target device.
Connecting to 1000BASE-T SFP
Caution
To prevent ESD damage, follow your normal board and component handling procedures.
Step 1
Connect one end of the cable to the SFP module port (
). When connecting to servers,
workstations, and routers, use a four twisted-pair, straight-through cable. When connecting to switches
or repeaters, use a four twisted-pair, crossover cable.
When connecting to a 1000BASE-T device, be sure to use a four twisted-pair, Category 5 or higher cable.
1
LC connector
Catalyst 2960
Series
1
2
3
4
47X
48X
254080
1