Technical Data
Introduction
8
Cisco C880 M4 Storage Subsystem Operating Manual for Server with E7-8800 v3 CPU
Environmental
Maximum heat generation
2.5": 1600 kJ/h (1517 btu/h)
Temperature (operating)
10 to 35°C
Temperature (not operating) 0 to 50°C
Temperature gradient
15°C/Hr or less
Humidity (operating)
20
– 80 % relative humidity, non-condensing
Humidity (not operating)
8
– 80 % relative humidity, non-condensing
Humidity gradient
30 %/day or less
Altitude
3,000 m
Sound power (LWAd; 1B =
10dB)
6.0 B
Sound pressure (LpAm)
43.5 db(A)
Noise notes
measured according to ISO7779 and declared
according to ISO9296
Compliance
Product safety
UL 60950-1, CSA-C22.2 No. 60950-1, EN 60950-1, IEC
60950-1
Electromagnetic
compatibility
CNS 13438, FCC Part-15 Class A, ICES 003 Class A, EN
55022 Class A, VCCI Class A, AS/NZS CISPR 22 Class
A
CE certification
2004/108/EC, 2006/95/EC, 2011/65/EC
Approvals
CB, CE, RCM, FCC, VCCI
Environmental
compliance
RoHS compliant, WEEE compliant
Compliance
notes
There is general compliance with the safety requirements
of all European countries and North America. National
approvals required in order to satisfy statutory regulations
or for other reasons can be applied for on request.