Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 28 Troubleshooting
Troubleshooting the BPX Switch
Displaying the Status of Cards in the Node
When a card indicates a failed condition on the alarm summary screen, use the Display Cards (
dspcds
)
command to display the status of the circuit cards on a node. The information displayed for each card
type includes the card slot number, software revision level, and the status of the card.
The possible status description for each card type are listed in Table 28-2. Refer to the
Cisco WAN
Switching Command Reference
for more information on the Display Cards command.
No BXM
card
or
port
LED
on.
No trunks or lines, as applicable on
card, are upped. Card has not
necessarily failed.
Up at least one of the trunks or lines, as applicable,
associated with the card (Trunks if BXM configured for
trunk mode, lines if BXM configured for port mode).
No BME
card
or
port
LED
on.
No lines are upped. Card has not
necessarily failed.
Up at least one of lines, as applicable, associated with
the card.
No BNI
card
or
port
LED
on.
No trunks on card are upped. Card
not necessarily failed.
Up at least one of the trunks associated with the card.
BXM
Port
LED is red or
orange (BXM configured for
port mode)
Line is in local or remote alarm.
Use NMS
dsplns
screen to confirm trouble.
BME
Port
LED is red or
orange
Line is in local or remote alarm.
Use NMS
dsplns
screen to confirm trouble.
BCC
fail
LED flashing
Downloading system software or
configuration data.
Wait for download to complete.
BCC
LAN
LED flashing
Normal for node connected to NMS
terminal over Ethernet. If it does
not
flash, there may be problems
with node to NMS data path.
Check that the cabling to the NMS is firmly connected
to the LAN port on the LM-BCC back card. An alternate
connection is to the control port.
No BCC card LED on.
Preparing to download new
software (momentary condition).
Wait for download to begin.
Command issued to run a software
revision that was not available in
the network.
Check that proper s/w revision is available on another
node or on NMS.
Table 28-1 Troubleshooting the BPX Switch (continued)
Symptom
Probable Cause
Remedy
Table 28-2 Card Status for the BPX Switch
Card Type
Status
1
Description
All card types
Active
Active card.
Active - F
Active card with no terminal failure.
Standby
Standby card.
Standby - F
Standby card with no terminal failure.
Standby - T
Standby card performing diagnostics.
Standby - F -T
Standby card with no terminal failure performing diagnostics.
Failed
Card with terminal failure.
Содержание BPX 8650
Страница 49: ...P A R T 1 The BPX Switch ...
Страница 50: ......
Страница 159: ...P A R T 2 Installation ...
Страница 160: ......
Страница 273: ...P A R T 3 Initial Configuration and Network Management ...
Страница 274: ......
Страница 311: ...P A R T 4 Configuring Connections ...
Страница 312: ......
Страница 487: ...P A R T 5 Troubleshooting and Maintenance ...
Страница 488: ......
Страница 533: ...P A R T 6 BPX Specifications ...
Страница 534: ......
Страница 555: ...P A R T 7 Appendices ...
Страница 556: ......