4-8
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 4 BNI (Trunk) Cards
T3 and E3 Line Modules (LM-3T3 and LM-3E3)
T3 and E3 Line Modules (LM-3T3 and LM-3E3)
The Line Modules for the BNI-T3 and BNI-E3 front cards are back cards used to provide a physical
interface to the transmission facility. The LM-3T3 is used with the BNI-T3. The LM-3E3 with the
BNI-3E3.
The Line Module connects to the BNI through the StrataBus midplane. You can make two adjacent cards
of the same type redundant by using a Y-cable at the port connectors. All three ports on a card must be
configured the same.
The LM-3T3 and LM-3E3 provides the following features:
•
BNC connectors for 75-ohm unbalanced signal connections to the transmit and receive of each of
the three ports.
•
Transformer isolation from the trunk lines.
•
Metallic relays for line loopback when in standby mode.
A final node loopback is at the end of the LM-3T3 or LM-3E3 card. This is a metallic loopback path that
uses a relay contact closure. It is a near-end loopback path only; the signal is looped at the final output
stage back to circuits in the node receive side. It is operated only when the corresponding front card is
in standby.
The faceplate connectors of the LM-3T3 and LM-3E3 are described in Table 4-3. There are no controls
or indicators.
Table 4-2
BNI Front Panel Card Failure Indications
act
stby
fail
Failure Description
on
off
on
Nonfatal error detected; the card is still active.
off
on
on
Nonfatal error detected; the card is in standby mode.
off
blinking
on
Fatal error detected; the card is in a reboot mode.
on
on
on
The card failed boot load and operation is halted.
Table 4-3
LM-3T3 and LM-3E3 Connectors
No
Connector
Function
1
PORT 1 RX - TX
BNC connectors for the transmit and receive T3/E3 signal to/from ATM
trunk 1.
2
PORT 2 RX - TX
BNC connectors for the transmit and receive T3/E3 signal to/from ATM
trunk 2.
3
PORT 3 RX - TX
BNC connectors for the transmit and receive T3/E3 signal to/from ATM
trunk 3.
Содержание BPX 8650
Страница 49: ...P A R T 1 The BPX Switch ...
Страница 50: ......
Страница 159: ...P A R T 2 Installation ...
Страница 160: ......
Страница 273: ...P A R T 3 Initial Configuration and Network Management ...
Страница 274: ......
Страница 311: ...P A R T 4 Configuring Connections ...
Страница 312: ......
Страница 487: ...P A R T 5 Troubleshooting and Maintenance ...
Страница 488: ......
Страница 533: ...P A R T 6 BPX Specifications ...
Страница 534: ......
Страница 555: ...P A R T 7 Appendices ...
Страница 556: ......