Value
Description
70 dB at 80.6°F (27°C) maximum
Acoustic noise
Operating (halfsine): 21 in/sec (0.53 m/sec)
Nonoperating (trapezoidal pulse): 20 G, 52 in/sec
(1.32 m/sec)
G is a value of acceleration, where 1G equals
32.17 ft/sec2 (9.81 m/sec2).
Note
Shock
Operating: 0.35 Grms from 3 to 500 Hz
Grms is the root mean square value of
acceleration.
Note
Nonoperating: 1.0 Grms from 3 to 500 Hz
Vibration
AC Electrical Specifications
Table 23: AC Electrical Specifications
Value
Description
Up to two AC power modules per system
Power modules per system
765 VA (volt-amps) per AC power supply(up to two
AC power supply modules per system)
Total AC input power
100
–
240 VAC nominal (range: 90 to 264
VAC)220
–
240 VAC (UK)
Rated input voltage
For each AC power supply
module.
Note
50/60 Hz nominal (range: 47 to 63 Hz)50/60 Hz (UK)
Rated input line frequency
15 A maximum at 100 VAC13 A maximum at 220
to 240 VRMS (UK)
Input current rating
15 A North America and Japan; 10 A international;
13 A UK
Source AC service requirement
Power redundancy requirements vary, based on
system configuration (number and type of line cards,
etc). AC and DC powered systems are N+1 protected.
Redundancy
Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide
121
Technical Specifications
AC Electrical Specifications