![Cisco ASR 9000 Serie Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/cisco/asr-9000-serie/asr-9000-serie_configuration-manuals_66679037.webp)
Alarms can be displayed according to severity level or a range of severity levels. Severity levels and their
respective system conditions are listed in
Table 2: Alarm Severity Levels for Event Logging , on page 6
under the
Alarm Severity Level and Filtering, on page 6
section.
The commands can be entered in any order.
Note
SUMMARY STEPS
1.
show logging events buffer severity-lo-limit severity
2.
show logging events buffer severity-hi-limit severity
3.
show logging events buffer severity-hi-limit severity severity-lo-limit severity
4.
show logging events buffer severity-hi-limit severity severity-lo-limit severity timestamp-lo-limit hh
: mm : ss
[
month
] [
day
] [
year
]
DETAILED STEPS
Purpose
Command or Action
(Optional) Displays logging events with a severity at or below the
numeric value of the specified severity level.
show logging events buffer severity-lo-limit
severity
Step 1
Example:
RP/0/RSP0/CPU0:router# show logging events
buffer severity-lo-limit notifications
•
In this example, alarms with a severity of notifications (severity
of 5) or lower are displayed. Informational (severity of 6) messages
are omitted.
Use the
severity-lo-limit
keyword and the
severity
argument
to specify the severity level
description
, not the numeric value
assigned to that severity level.
Note
(Optional) Displays logging events with a severity at or above the
numeric value specified severity level.
show logging events buffer severity-hi-limit
severity
Step 2
Example:
RP/0/RSP0/CPU0:router# show logging events
buffer severity-hi-limit critical
•
In this example, alarms with a severity of critical (severity of 2) or
greater are displayed. Alerts (severity of 1) and emergencies
(severity of 0) are omitted.
Use the
severity-hi-limit
keyword and the
severity
argument
to specify the severity level
description
, not the numeric value
assigned to that severity level.
Note
(Optional) Displays logging events within a severity range.
show logging events buffer severity-hi-limit
severity severity-lo-limit severity
Step 3
•
In this example, alarms with a severity of critical (severity of 2)
and alerts (severity of 1) are displayed. All other event severities
are omitted.
Example:
RP/0/RSP0/CPU0:router# show logging events
buffer severity-hi-limit alerts
severity-lo-limit critical
Cisco ASR 9000 Series Aggregation Services Router System Monitoring Configuration Guide, Release 4.2.x
21
Implementing and Monitoring Alarms and Alarm Log Correlation
Displaying Alarms by Severity and Severity Range