Step 3
When using the streetlight power tap adapter (AIR-PWR-ST-LT-R3P=), ensure that the access point is
mounted within 3 feet (1 m) of the outdoor light control.
Step 4
Ensure that a 6-AWG ground wire is attached to the access point (see
) and connected to the
streetlight pole (for instructions see
Grounding the Access Point, page 2-40
Figure 2-33
Using the Streetlight Power Tap Adapter
Note
Deployment of the AP as shown in the streetlight deployment in
requires an
alternate AP mounting kit. See
section for more information.
Step 5
Ensure that the streetlight power tap adapter, which uses a 3-pronged LC-10 twist-lock adapter, is placed
between the outdoor light control and its fixture (refer to
). The LC-10 twist-lock adapter is
designed to be used with LC-10 listed outdoor light controls operating at 100 to 480 VAC, 50 to 60 Hz.
Step 6
Disconnect the outdoor light control from its fixture.
Step 7
Verify that the voltage available at the fixture is between 100 and 480 VAC, 50 to 60 Hz.
Step 8
Turn off power to the fixture at the designated circuits.
Caution
When installing the streetlight power tap adapter to the access point AC power connector, always
connect the access point end of the cable FIRST. When removing the streetlight power tap adapter,
always disconnect the access point end of the cable LAST.
Note
Ensure that your antennas are connected to the access point before you apply power to the access
point.
Step 9
Connect the streetlight power tap adapter to the access point
AC/DC power adapter. Hand-tighten the
connector.
1
Outdoor light control
3
6-AWG copper grounding wire
2
AC/DC power adapter
1962
1
2
3
AC/DC
Adapter